Dynamic Characteristic of A Bi-dirctional Damper Using A Tuned Mass Damper and A Tuned Liquid Column Damper

TMD와 TLCD를 이용한 2방향 감쇠기의 동적특성

  • Published : 2008.12.30

Abstract

This study introduces the design of a bi-directional damper using a tuned mass damper(TMD) and a tuned liquid column damper(TLCD) and presents experimental verifications to confirm its control performance. The damper used in this study behaves as a TMD in a specific translational direction and acts as a TLCD in the other orthogonal direction. First, shaking table test is performed to investigate the coupled effect of control forces produced by TMD and TLCD. Then, the parameters that affect to dynamic characteristics of the proposed damper are quantitatively evaluated based on the experimental results. Testing results shows that the damper used in this study produces control forces coupled by TLCD and TMD, as it is excited by waves with an incident angle. Also, it is observed that the damper can be used to reduce bi-directional responses of building structures.

본 연구에서는 동조질량감쇠기(TMD)와 동조액체 기둥감쇠기(TLCD)로 구성된 2방향 감쇠기의 제어성능을 실험적으로 검증하였다. 본 연구에 사용된 감쇠기는 한방향으로는 TMD로 거동하고, 다른 직교하는 방향에서는 TLCD로 거동하여 제어력이 발생하는 감쇠기이다. 우선, 제작된 감쇠기의 동적특성과 TMD와 TLCD에 의해 발생하는 제어력들의 연계효과를 조사하기 위한 진동대 실험을 수행하였다. 다음으로 이러한 실험결과를 바탕으로 감쇠기의 동적특성에 영향을 미치는 파라미터를 정량적으로 평가하였다. 본 연구에서 사용된 감쇠기가 입사각을 갖는 진동에 의해 가진될 때 TMD와 TLCD에 의해 연계된 제어력이 발생하는 것을 진동대 실험결과로부터 확인하였다. 또한, 감쇠기가 건축물의 2방향 응답제어에도 효과적으로 사용될 수 있음을 확인하였다.

Keywords

References

  1. 허재성, 박은천, 이상현, 이성경, 김홍진, 조봉호, 조지성, 김동영, 민경원 (2008a) 건축구조물의 2방향 진동제어를 위한 동조액체질량감쇠기, 한국소음진동공학회 논문집, 18(3), pp.345-355 https://doi.org/10.5050/KSNVN.2008.18.3.345
  2. 허재성, 이성경, 박은천, 이상현, 김홍진, 조지성, 조봉호, 민경원 (2008b) 실시간 하이브리드 진동대 실험법에 의한 양방향 TLMD의 진동제어 성능평가, 한국소음진동공학회 논문집, 18(5), pp.485-495 https://doi.org/10.5050/KSNVN.2008.18.5.485
  3. 허재성, 박은천, 이성경, 이상현, 김홍진, 조지성, 조봉호, 주석준, 민경원 (2008c) 실물크기 구조물에 설치된 동조액 체질량감쇠기의 성능실험, 한국전산구조공학회 논문집, 21(2), pp.161-168
  4. Almazan, J. L., Llera, J. C., Inaudi, J. A., Garcia, D. L., Izquierdo, L. E. (2007) A bidirectional and homogeneous tuned mass damper: A new device for passive control of vibrations. Engineering Structures. 29. pp.1548-1560 https://doi.org/10.1016/j.engstruct.2006.09.005
  5. Den Hartog, J. P. (1956) Mechanical vibrations, McGraw-Hill
  6. Desu, N. B., Deb, S. K., Dutta, A. (2006) Coupled tuned mass dampers for control of coupled vibrations in asymmetric buildings. Struct. Control Health Monit., 13, pp.897-916 https://doi.org/10.1002/stc.64
  7. Gao, H., Kwok, K. C. S. (1997) Optimization of tuned liquid column dampers, Engineering Structures, 19(6), pp.476-486 https://doi.org/10.1016/S0141-0296(96)00099-5
  8. Hitchcock, P. A., Kwok, K C. S., Watkins, R. D. (1997a) Characteristics of liquid column vibration absorbers (LCVA)-I, Engineering Structures, 19(2), pp.126-134 https://doi.org/10.1016/S0141-0296(96)00042-9
  9. Hitchcock, P. A., Kwok, K. C. S., Watkins, R. D. (1997b) Characteristics of liquid column vibration absorbers (LCVA)- II, Engineering Structures, 19(2), pp.135-144 https://doi.org/10.1016/S0141-0296(96)00044-2
  10. Reiterer, M., Ziegler, F. (2005) Bi-axial seismic activation of civil engineering structures equipped with tuned liquid column dampers, JSEE: Spring, 7(1), pp.45-60
  11. Sakai, F., Takaeda, S., Tamaki, T. (1989) Tuned Liquid Column Damper - New Type Device for Suppression of Building Vibrations, Proc. Int. ConI. on Higbrise Buildings, Nanjing. China, pp.926-931
  12. Shum, K. M. (2008) Closed form optimal solution of a tuned liquid column damper for supressing harmonic vibration of structures, Engineering Structures, doi:10.1016/j.engstruct. 2008.07. 015, in press
  13. Soong, T. T., Dargush, G. F. (1997) Passive Energy Dissipation Systems in Structural Enginnering, John Wiley & Sons
  14. Ueng, J. M., Lin, C. C., Wang, J. F. (2008) Practical design issues of tuned mass dampers for torsionally coupled buildings under earthquake loadings, Struct. Design Tall Spec. Build., 17, pp.133-165 https://doi.org/10.1002/tal.336
  15. Xu, Y. L., Samali, B., Kwok, K. C. S. (1992) Control of along-wind response of structures by mass and liquid dampers, Journal of Engineering Mechanics, 118(1), pp.20-39 https://doi.org/10.1061/(ASCE)0733-9399(1992)118:1(20)
  16. Yalla, S. K., Kareem, A. (2000) Optimum absorber parameters for tuned liquid column dampers, Journal of Structural Engineering, 126(8), pp.906-915 https://doi.org/10.1061/(ASCE)0733-9445(2000)126:8(906)
  17. Zhang, X. T., Zhang, R. C., Xu, Y. L. (1993a) Analysis on control of flow-induced vibration by tuned liquid damper with crossed tube-like containers, Journal of Wind Engineering and Industrial Aerodynamics, 50, pp.351-360 https://doi.org/10.1016/0167-6105(93)90090-B
  18. Zhang, X. T., Zhang, R. C. (1993b) On control of along-wind and across-wind vibrations of structure by crossed dampers, Proc. Third Asia-Pacific Symp. on Wind Engineering, Hong Kong, 2, pp.859-864