DOI QR코드

DOI QR Code

A Continuous Particle-size Sorter Using Negative a Dielectrophoretic Virtual Pillar Array

음의 유전영동에 의한 가상 기둥 어레이를 이용한 연속적 입자 크기 분류기

  • 장성환 (한국과학기술원 바이오및뇌공학과, 디지털나노구동연구단) ;
  • 조영호 (한국과학기술원 바이오및뇌공학과/기계공학과, 디지털나노구동연구단)
  • Published : 2008.11.01

Abstract

We present a continuous size-dependent particle separator using a negative dielectrophoretic (DEP) virtual pillar array. Two major problems in the previous size-dependent particle separators include the particle clogging in the mechanical sieving structures and the fixed range of separable particle sizes. The present particle separator uses the virtual pillar array generated by negative DEP force instead of the mechanical pillar array, thus eliminating the clogging problems. It is also possible to adjust the size of separable particles since the size of virtual pillars is a function of a particle diameter and applied voltage. At an applied voltage of 500 kHz $10\;V_{rms}$ (root mean sqaure voltage) sinusidal wave and a flow rate of $0.40\;{\mu}l\;min^{-1}$, we separate $5.7\;{\mu}m$-, $8.0\;{\mu}m$-, $10.5\;{\mu}m$-, and $11.9\;{\mu}m$-diameter polystyrene (PS) beads with separation purity of 95%, 92%, 50%, and 63%, respectively. The $10.5\;{\mu}m$- and $11.9\;{\mu}m$-diameter PS beads have relatively low separation purity of 50% and 63%. However, at an applied voltage of $8\;V_{rms}$, we separate $11.9\;{\mu}m$-diameter PS beads with separation purity over 99%. Therefore, the present particle separator achieves clog-free size-dependent particle separation, which is capable of size tuning of separable particles.

Keywords

References

  1. Blattert, C., Jurischka, R., Schoth, A., Kerth, O., and Menz, W., 2003, "Separation of Blood in Microchannel Bends," Proceeding of the 25th Annual International Conference of IEEE EMBS, pp. 3388~3391
  2. Huang, L. R., Cox, E. C., Austin, R. H., and Sturm, J. C., 2004, "Continuous Particle Separation Through Deterministic Lateral Displacement," Science, Vol. 304, pp. 987~990 https://doi.org/10.1126/science.1094567
  3. Zheng, S., Yung, R., Tai, Y. -C., and Kasdan, H., 2005, "Deterministic Lateral Displacement MEMS Device for Continuous Blood Cell Separation," Proceeding of International Conference on Micro Electro Mechanical Systems, pp. 851~854
  4. Takagi, J., Yamada, M., Yasuda, M., and Seki, M., 2005, “Continuous Particle Separation in a Microchannel Having Asymmetrically Arranged Multiple Branches,” Lab on a chip, Vol. 5, pp. 778~784 https://doi.org/10.1039/b501885d
  5. Chang, W. C., Lee, L. P., and Liepmann, D., 2005, “Biomimetic Technique for Adhesion-Based Collection and Separation of Cells in a Microfluidic Channel,” Lab on a chip, Vol. 5, pp. 64~73 https://doi.org/10.1039/b400455h
  6. Han, K. -H., and Frazier, A. B., 2004, "Continuous Magnetophoretic Separation of Blood Cells in Microdevice Format," Journal of Applied Physics, Vol. 96, No. 10, pp. 5797~5802 https://doi.org/10.1063/1.1803628
  7. Hughes, M. P., 2002, "Strategies for Dielectrophoretic Separation in Laboratory-on-a-chip systems," Electrophoresis, Vol. 23, No. 16, pp. 2569~2582 https://doi.org/10.1002/1522-2683(200208)23:16<2569::AID-ELPS2569>3.0.CO;2-M
  8. Doh, I. and Cho, Y.-H., 2005, "A Continuous Cell Separation Chip Using Hydrodynamic Dielectrophoresis (DEP) Process," Sensors and Actuators, A, Vol.121, pp. 59~65 https://doi.org/10.1016/j.sna.2005.01.030
  9. Choi, S. and Park, J.-K, 2005, "Microfluidic System for Dielectrophoretic Separation Based on a Trapezoidal Electrode Array,” Lab on a Chip, Vol.5, pp. 1161~1167 https://doi.org/10.1039/b505088j
  10. Mukhopadhyay, R., 2005, "When Microfluidic Devices Go Bad. How does Fouling Occur in Microfluidic Devices, and What can be Done About It?," Analytical Chemistry, Vol. 77, No. 21, pp. 429A~432A
  11. De Mello, A. J., 2006, “Research Highlights,” Lab on a chip, Vol. 6, pp. 16~18 https://doi.org/10.1039/b517018b
  12. Roy, D. N., 1998, Applied Fluid Mechanics, Ellis Horwood Limited, chapter 10

Cited by

  1. Analysis of Particle Motion in Quadrupole Dielectrophoretic Trap with Emphasis on Its Dynamics Properties vol.38, pp.10, 2014, https://doi.org/10.3795/KSME-B.2014.38.10.845