An Analysis of Radiation Field Characteristics for Estimating the Extremity Dose in Nuclear Power Plants

원전 종사자의 말단선량평가를 위한 고피폭 접촉 방사선장 특성분석

  • Published : 2009.12.30

Abstract

Maintenance on the water chamber of steam generator during outage in nuclear power plants (NPPs) has a likelihood of high radiation exposure to whole body of workers even short time period due to the high radiation exposure rates. In particular, it is expected that hands would receive the highest radiation exposure because of its contact with radiation materials. In this study, characteristic analysis of inhomogeneous radiation fields for contact operations was conducted using thermoluminescent dosimeter (TLD) readouts from the application tests of two-dosimeter algorithm to Korean NPPs in 2004. It is regarded that inhomogeneous radiation fields for contact operations in NPPs are dominated by high energy photons. In addition, field tests for workers who participated in maintenance on the steam generator during outage at Ulchin NPPs in 2009 and pressure tube replacement at Wolsong NPPs in 2009 were conducted to analyze radiation fields and to estimate the extremity dose. As a result, radiation fields were dominated by high energy photons.

원전 계획예방정비기간 증기발생기 수실작업 등은 매우 높은 방사선량율을 보이는 지역으로, 짧은 시간 동안 작업으로 종사자는 높은 피폭을 받을 가능성이 있다. 특히, 방사성물질과 접촉작업을 하는 손 부위에서 고피폭이 예상된다. 이런 점을 고려하여 2004년 수행된 국내 원전의 복수선량계 알고리즘 적용성 시험의 TLD 판독결과를 이용하여 고피폭 접촉 작업의 방사선장을 분석하였다. 그 결과, 원전 고피폭 접촉작업의 입사방사선장은 고에너지 광자(High Energy Photon Field)에 의한 피폭으로 해석되었다. 한편 2009년 울진 4호기 계획예방정비기간 S/G 정비작업과 월성 1호기 압력관 교체작업에 참여한 방사선작업종사자에 대해 말단선량 현황과 방사선장을 분석하기위한 현장시험을 실시하였다. 그 결과 입사방사선장은 고에너지 방사선장으로 확인되었다.

Keywords

References

  1. International Commission on Radiological Protection. 1990 Recommendations of the International Commission on Radiological Protection. ICRP Publication 60. Pergamon Press, 1991
  2. International Atomic Energy Agency. Basic Safety Standards for Protection against Ionizing Radiation and for the Safety of Radiation Sources. IAEA Safety Series No. 115, Vienna, 1996
  3. 교육과학기술부. 고시 제2008-31호: 방사선방호등에 관한 기준 고시, 2008
  4. International Commission on Radiological Protection. The 2007 Recommendations of the International Commission on Radiological Protection. ICRP Publication 103, Pergamon Press, 2007
  5. 교육과학기술부 고시 제2008-48호: 판독업무 등록 기준 및 검사 규정, 2008
  6. International Commission on Radiation Units and Measurements. Quantities and Units in Radiation Protection Dosimetry. ICRU Report 51, 1993
  7. American National Standard Institute. An American National Standard for Dosimetry - Personnel Dosimetry Performance Criteria for Testing. ANSI N13.11, 1993
  8. American National Standard Institute. An American National Standard - Performing Testing of Extremity Dosimeters. ANSI N13.32, 1995
  9. Harshaw Brochure, Extremity Dosimeter, 2008
  10. Panasonic Brochure, Extremity Dosimeter, 2008
  11. Ocken H. Techniques for Controlling Radiation Exposure. Nuclear News 1993 Feb;43-47
  12. Yoon YH. Shielding Establishment inside Steam Generator, Proceedings of Information System on Occupational Exposure. Asian ALARA Symposium, 2007
  13. 김희근, 공태영. 원전 불균일 방사선장하에서 유효선량 평가를 위한 복수선량계 알고리즘 적용방안 연구. Journal of Radiation Protection 2008;33(4):151-160
  14. 한전전력연구원. 원전 말단선량계의 방사선장 특성 조사 분석. TM.S04.R2009.0012, 2009
  15. 한전전력연구원, 열형광선량계에 의한 실효선량당량 평가기술 및 알고리즘 개발, KRC-90N-J03, 1992
  16. 송명재, 김희근, 김봉환, 장시영. PWR 발전에서의 방사선장 특성. 방사선방어학회지 1992;17(2):61-70
  17. 한전전력연구원. 원전 1차계통 방사선량 감소 기술 개발. KRC-90N-J04, 1993
  18. 한전전력연구원. 원전 고피폭 접촉작업의 방사선장 특성분석 및 말단선량 현황분석 보고서. TM.S04. P2009.0190, 2009
  19. 한전전력연구원. 고피폭 접촉작업(압력관피더 제거 작업 등) 방사선장 특성분석 및 말단선량 평가보고서 (월성 1호기 압력관교체기간 말단선량계 패용 현장시험 분석보고서). TM.F02.P2009.0616, 2009