DOI QR코드

DOI QR Code

Precision and Safety Comparison for SM, CRM and ATD in Phase I Clinical Trials

제 1상 임상시험의 SM, CRM, ATD에서 결정된 MTD의 정확성과 안전성 비교

  • 김동욱 (성균관대학교 통계학과) ;
  • 길순경 (LG히다찌(주) 솔루션컨설팅팀)
  • Published : 2009.01.31

Abstract

The purpose of a phase I clinical trial is to determine the maximum tolerated dose(MTD) of a new drug. This paper investigates the performance of standard method, continual reassessment method and accelerated titration designs in phase I clinical trials. Especially we study the precision and safety at the MTD of these methods. We utilize hyperbolic tangent function and power function to define dose-toxicity model. For each method, expected toxicity rate at MTD is computed and compared with target toxicity probability. We also suggest some modifications of these methods and show some improvements in performance.

제 1상 임상시험은 사람을 대상으로 처음 실시되므로 약물 투여의 안전성과 정확성이 신중히 고려되어야 한다. 따라서 제 1상 임상시험에서는 적은 수의 피험자를 통해 최대허용용량(maximum tolerated dose)을 정확하게 찾아야 한다. 제 1상 임상시험에서 최대허용용량을 결정하는 방법에는 표준방법(standard method), 연속재평가방법(continual reassessment method) 그리고 가속적정계획(accelerated titration designs) 방법이 있다. 본 연구에서는 동일한 모형에서 세 방법을 동시에 고려하여 최대허용용량의 안전성과 정확성을 살펴보았다. 또한 세 방법에 대해 최대허용용량에서 기대독성확률을 구하여 비교하였다. 그리고 ATD와 CRM의 단점을 보완한 수정된 ATD와 수정된 CRM을 포함하여 여러 방법들을 동일한 모형에서 동시에 그 성능을 비교하였다.

Keywords

References

  1. 강승호 (2002). 1상 임상실험에서 수정된 CRM에 대한 연구, <응용통계연구>, 15, 323-336 https://doi.org/10.5351/KJAS.2002.15.2.323
  2. Kang, S. H. (2003). Consistency and asymptotic normality of a modified likelihood approach continual reassessment method, Journal of the Korean Statistical Society, 32, 33-46
  3. Korn, E. L., Midthune, D., Chen, T. T., Rubinstein, L. V., Christian, M. C. and Simon, R. (1994). A Comparison of two phase I trial designs, Statistics in Medicine, 13, 1799-1806 https://doi.org/10.1002/sim.4780131802
  4. O’Quigley, J., Pepe, M. and Fisher, L. (1990). Continual reassessment method: A practical design for phase 1 clinical trials in cancer, Biometrics, 46, 33-48 https://doi.org/10.2307/2531628
  5. O'Quigley. J. and Shen, L. Z. (1996). Continual reassessment method: A likelihood approach, Biometrics, 52, 673-684 https://doi.org/10.2307/2532905
  6. Simon, R., Freidlin, B., Rubinstein, L., Arbuck, S. G., Collins, J. and Christian, M. C. (1997). Accelerated titration designs for phase I clinical trials in oncology, Journal of the National Cancer Institute, 89, 1138-1147 https://doi.org/10.1093/jnci/89.15.1138
  7. Storer, B. E. (1989). Design and analysis of phase I clinical trials, Biometrics, 45, 925-937 https://doi.org/10.2307/2531693

Cited by

  1. Maximum Tolerated Dose Estimate by Curve Fitting in Phase I Clinical Trial vol.18, pp.2, 2011, https://doi.org/10.5351/CKSS.2011.18.2.179
  2. Maximum Tolerated Dose Estimation by Stopping Rule and SM3 Design in a Phase I Clinical Trial vol.27, pp.1, 2014, https://doi.org/10.5351/KJAS.2014.27.1.013