A Study on Verification for the Design of Bio Safety Level 3 Laboratory by using Multi-zone Simulation

멀티죤 시뮬레이션을 이용한 생물안전 3등급(BSL3)시설의 설계 검증에 관한 연구

  • Published : 2009.12.10

Abstract

In Korea, since the implementation of the LMO Law, the interest of biosafety level 3(BL3) lab. is increasing. In this study, using CONTAM which is applying multizone modelling, the multizone simulation for design verification of BL3 lab. is performed. In BL3 lab., because required air change rate is greater than general estimated air-conditioning load and it is difficult to maintain room pressure difference efficiently, to maintain pressure difference between laboratory rooms is important through sealing condition of doors and proper airflow control of laboratory rooms. In this study, about BL3 lab,(M. tuberculosis research lab.), the multizone simulation for four kind of biohazard scenarios is carried out in the case of unexpected spread of contaminants in the laboratory room, anteroom, corridor and inside of BSC. Multizone simulation results show that these approach methods are used as a tool for the design and verification of BL3 lab.

Keywords

References

  1. Korea Center for Disease Control and Prevention, According to between nations transper of living Modified Organisms etc of Law, 2008
  2. S. G. Choi and J. K. Hong, 2007, The Study on the Multi-zone Simulation according to Building Ventilation System for Preventing Transmission of Microorganism by Air Borne Contagion, Journal of AIK, Vol. 23, No. 6, pp. 247-245
  3. S. G. Choi and J. K. Hong, 2007, The Study on the Disinfection performance of Indoor Microorganism using Energy Consumption Analysis through the Linked Model of CONTAM and TRANSYS", Proceedings of International Conference on Sustainalle Building Asia(SB 07 Seoul)
  4. H. W. Lee, S. G. Choi and J. K. Hong, 2008, A Study on the Microbial Contaminant Transport and Control Method According to Government Building Bio-Attack, Journal of SAREK, Vol. 20, No. 4., pp. 252-260
  5. J. K. Hong and S. G. Choi, 2007, A Study on the Diffusion and Removal of Airborne Microorganism Pollution in Multistoried Apartment by the Multi-Zone Simulation, Journal of SAREK, Vol. 19, No. 4, pp. 291-299
  6. National Technical Information Service U. S. Department of Commerce Springfield, VA 22161
  7. ASHRAE Handbook, 1997, American Society Heating, Refrigerating and Air-Conditioning Engineers. Inc, Atlanta, GA. Chapter 25, p. 18
  8. Walton, G. N., 2005, CONTAM2.4 User Guide and Program Documentation, NISTIR 7251
  9. ASHRAE Handbook, 1995. American Society Heating, Refrigerating and Air-Conditioning Engineers, Inc, Atlanta, GA. Chapter 13, p. 6
  10. ARS Manual-242 2002, Facilities Design Standards, pp. 180-255