Effect of Reinforcement details on the Seismic Performance of Precast Strain-Hardening Cementitious Composite(SHCC) Infill Walls

보강상세에 따른 프리캐스트 변형경화형 시멘트 복합체 끼움벽의 내진성능

  • Received : 2009.01.02
  • Accepted : 2009.04.17
  • Published : 2009.05.30

Abstract

Flexible frames on their own offer little resistance to lateral forces, resulting often in large deflections and rotations at the joints. On the other hand, walls subjected to lateral loads fail mainly in shear at relatively small displacements. Therefore, when the nonductile frames and wall act together, the combined action of the composite system differs significantly from that of the frame or wall alone. The objective of the study is to evaluate seismic response of infill walls with notched midsection. Reinforcement detail of wall was main variable in the experiment. Also SHCC was used in order to prevent damage concentration into notched midsection of walls. Test results, SHCC infill walls show the multiple crack patterns as expected. However, PIW-ND specimen exhibits less story drift, stiffness and energy dissipation capacity than those of PIW-NC specimen.

비내진상세 골조는 낮은 횡저항성을 가지고 있어 큰 변형을 경험하게 되는 반면, 벽체는 높은 강성으로 인해 낮은 변형에서도 전단에 의해 파괴된다. 따라서 이러한 골조와 벽체가 동시에 거동할 경우 발생하는 거동 특성은 개개 부재에서의 거동특성과 매우 다르게 된다. 본 연구에서는 끼움벽에 노치를 둘 경우 내진거동특성을 평가하고자 배근상세를 변수로 하였다. 이 때 노치로 인해 벽체 중앙부에 손상이 집중되는 것을 방지하기 위하여 변형경화형 시멘트 복합체(SHCC)를 사용하였다. 실험결과, SHCC 끼움벽은 다수의 미세균열을 형성하였으나, 대각보강근을 갖는 PIW-ND 실험체가 PIW-NC 실험체에 비해 낮은 변형능력, 강성 및 에너지소산능력을 보였다.

Keywords

References

  1. 기상청, 2008, http://www.kma.go.kr
  2. 대한건축학회, "건축구조설계기준", 2005
  3. 윤현도, 김선우, 이갑원, 최창식, 이혜연, "고인성 시멘트 복합체를 사용한 끼움벽으로 보강된 비내진 상세철근콘크리트 골조의 내진성능", 대한건축학회 논문집(구조계), Vol. 22, No. 5, 2006, pp. 31-38
  4. 윤현도, 김용철, 김선우, "보강섬유 종류에 따른 변형경화형 시멘트 복합체의 거동특성", 대한건축학회 논문집(구조계), Vol. 24, No. 5, 2008, pp. 141-148
  5. (財)日本建築総合試驗所構造部, "鐵筋コンクリㅡト增設壁耐震補强設計及び施工指針", 2001
  6. 社團法人 日本コンクリ-ト工學協會, "高靭性セメント複合材料の性能評價と構造利用硏究委員會", 2004, pp. 195
  7. American Concrete Institute, "Building CodeRequirements for Reinforced Concrete and Commentary", ACI 318-02, American Concrete Institute, 2002
  8. Sugano, S., "Guidelines for Seismic Retrofitting(Strengthening, Toughening, and/or Stiffening),Design of Existing Reinforced Concrete Buildings",Proceeding of the Second Seminar on Repair and Retrofit of Structures, Ann Arbor, Michigan, May 1981, pp. 189-246
  9. Yun, H.D., Kim, S.W., Jeon, E., "Mechanicalproperties of high performance hybrid fibrereinforced cementitious composites (HPHFRCCs)",MAGAZINE OF CONCRETE RESEARCH, Vol.59, No. 4, 2007, pp. 257-271 https://doi.org/10.1680/macr.2007.59.4.257