DOI QR코드

DOI QR Code

The Image Quality and Radiation Dose of 100-kVp versus 120-kVp ECG-Gated 16-Slice CT Coronary Angiography

Park, Eun-Ah;Lee, Whal;Kang, Jin-Hwa;Yin, Yong Hu;Chung, Jin-Wook;Park, Jae-Hyung

  • Published : 20090600

Abstract

Objective: This study was conducted to assess the feasibility of performing 100-kVp electrocardiogram (ECG)-gated coronary CT angiography, as compared to 120-kVp ECG-gated coronary CT angiography. Materials and Methods: We retrospectively evaluated one hundred eighty five gender- and body mass index-matched 16-slice coronary CT sets of data, which were obtained using either 100 kVp and 620 effective mAs or 120 kVp and 500 effective mAs. The density measurements (image noise, vessel density, signal-tonoise ratio [SNR] and contrast-to-noise ratio [CNR]) and the estimated radiation dose were calculated. As a preference test, two image readers were independently asked to choose one image from each pair of images. The results of both protocols were compared using the paired t-test or the Wilcoxon signed rank test. Results: The 100-kVp images showed significantly more noise and a significantly higher vessel density than did the 120-kVp images. There were no significant differences in the SNR and CNR. The estimated reduction of the radiation dose for the 100-kVp protocol was 24%; 7.8 ${\pm}$ 0.4 mSV for 100-kVp and 10.1 ${\pm}$ 1.0 mSV for 120-kVp (p < 0.001). The readers preferred the 100-kVp images for reading (reader 1, p = 0.01; reader 2, p = 0.06), with their preferences being stronger when the subject’s body mass index was less than 25. Conclusion: Reducing the tube kilovoltage from 120 to 100 kVp allows a significant reduction of the radiation dose without a significant change in the SNR and the CNR.

Keywords

References

  1. Ghersin E, Litmanovich D, Dragu R, Rispler S, Lessick J, Ofer A, et al. 16-MDCT coronary angiography versus invasive coronary angiography in acute chest pain syndrome: a blinded prospective study. AJR Am J Roentgenol 2006;186:177-184 https://doi.org/10.2214/AJR.04.1232
  2. Haberl R, Tittus J, Bo ¨hme E, Czernik A, Richartz BM, Buck J,et al. Multislice spiral computed tomographic angiography ofcoronary arteries in patients with suspected coronary arterydisease: an effective filter before catheter angiography? AmHeart J 2005;149:1112-1119 https://doi.org/10.1016/j.ahj.2005.02.048
  3. Abada HT, Larchez C, Daoud B, Sigal-Cinqualbre A, Paul JF. MDCT of the coronary arteries: feasibility of low-dose CT with ECG-pulsed tube current modulation to reduce radiation dose. AJR Am J Roentgenol 2006;186:S387-S390 https://doi.org/10.2214/AJR.05.0216
  4. Hausleiter J, Meyer T, Hadamitzky M, Huber E, Zankl M,Martinoff S, et al. Radiation dose estimates from cardiac multislice computed tomography in daily practice: impact of different scanning protocols on effective dose estimates. Circulation 2006;113:1305-1310 https://doi.org/10.1161/CIRCULATIONAHA.105.602490
  5. d’Agostino AG, Remy-Jardin M, Khalil C, Delannoy-Deken V, Flohr T, Duhamel A, et al. Low-dose ECG-gated 64-slices helical CT angiography of the chest: evaluation of image quality in 105 patients. Eur Radiol 2006;16:2137-2146 https://doi.org/10.1007/s00330-006-0218-1
  6. Hohl C, Mu ¨hlenbruch G, Wildberger JE, Leidecker C, Su ¨ss C, Schmidt T, et al. Estimation of radiation exposure in low-dose multislice computed tomography of the heart and comparison with a calculation program. Eur Radiol 2006;16:1841-1846 https://doi.org/10.1007/s00330-005-0124-y
  7. Paul JF, Abada HT. Strategies for reduction of radiation dose in cardiac multislice CT. Eur Radiol 2007;17:2028-2037 https://doi.org/10.1007/s00330-007-0584-3
  8. Jakobs TF, Becker CR, Ohnesorge B, Flohr T, Suess C, Schoepf UJ, et al. Multislice helical CT of the heart with retrospective ECG gating: reduction of radiation exposure by ECG-controlled tube current modulation. Eur Radiol 2002;12:1081-1086 https://doi.org/10.1007/s00330-001-1278-x
  9. Hsieh J, Londt J, Vass M, Li J, Tang X, Okerlund D. Step-andshoot data acquisition and reconstruction for cardiac x-ray computed tomography. Med Phys 2006;33:4236-4248 https://doi.org/10.1118/1.2361078
  10. McCollough CH, Primak AN, Saba O, Bruder H, Stierstorfer K, Raupach R, et al. Dose performance of a 64-channel dual-source CT scanner. Radiology 2007;243:775-784 https://doi.org/10.1148/radiol.2433061165
  11. Earls JP, Berman EL, Urban BA, Curry CA, Lane JL, Jennings RS, et al. Prospectively gated transverse coronary CT angiography versus retrospectively gated helical technique: improved image quality and reduced radiation dose. Radiology 2008;246:742-753 https://doi.org/10.1148/radiol.2463070989
  12. Johnson TR, Nikolaou K, Wintersperger BJ, Leber AW, von Ziegler F, Rist C, et al. Dual-source CT cardiac imaging: initial experience. Eur Radiol 2006;16:1409-1415 https://doi.org/10.1007/s00330-006-0298-y
  13. Kalender WA, Wolf H, Suess C, Gies M, Greess H, Bautz WA. Dose reduction in CT by on-line tube current control: principles and validation on phantoms and cadavers. Eur Radiol 1999;9:323-328 https://doi.org/10.1007/s003300050674
  14. Schoenhagen P. Back to the future: coronary CT angiography using prospective ECG triggering. Eur Heart J 2008;29:153-154
  15. Stolzmann P, Leschka S, Scheffel H, Krauss T, Desbiolles L, Plass A, et al. Dual-source CT in step-and-shoot mode: noninvasive coronary angiography with low radiation dose. Radiology 2008;249:71-80 https://doi.org/10.1148/radiol.2483072032
  16. Stolzmann P, Scheffel H, Schertler T, Frauenfelder T, Leschka S, Husmann L, et al. Radiation dose estimates in dual-source computed tomography coronary angiography. Eur Radiol 2008;18:592-599 https://doi.org/10.1007/s00330-007-0786-8
  17. Heyer CM, Mohr PS, Lemburg SP, Peters SA, Nicolas V. Image quality and radiation exposure at pulmonary CT angiography with 100- or 120-kVp protocol: prospective randomized study. Radiology 2007;245:577-583 https://doi.org/10.1148/radiol.2452061919
  18. Sigal-Cinqualbre AB, Hennequin R, Abada HT, Chen X, Paul JF. Low-kilovoltage multi-detector row chest CT in adults: feasibility and effect on image quality and iodine dose. Radiology 2004;231:169-174 https://doi.org/10.1148/radiol.2311030191
  19. Wintersperger B, Jakobs T, Herzog P, Schaller S, Nikolaou K, Suess C, et al. Aorto-iliac multidetector-row CT angiography with low kV settings: improved vessel enhancement and simultaneous reduction of radiation dose. Eur Radiol 2005;15:334-341 https://doi.org/10.1007/s00330-004-2575-y
  20. Schueller-Weidekamm C, Schaefer-Prokop CM, Weber M, Herold CJ, Prokop M. CT angiography of pulmonary arteries to detect pulmonary embolism: improvement of vascular enhancement with low kilovoltage settings. Radiology 2006;241:899-907 https://doi.org/10.1148/radiol.2413040128
  21. Jung B, Mahnken AH, Stargardt A, Simon J, Flohr TG, Schaller S, et al. Individually weight-adapted examination protocol in retrospectively ECG-gated MSCT of the heart. Eur Radiol 2003;13:2560-2566 https://doi.org/10.1007/s00330-003-2111-5
  22. Huda W, Scalzetti EM, Levin G. Technique factors and image quality as functions of patient weight at abdominal CT. Radiology 2000;217:430-435
  23. Kalra MK, Maher MM, Toth TL, Hamberg LM, Blake MA, Shepard JA, et al. Strategies for CT radiation dose optimization. Radiology 2004;230:619-628 https://doi.org/10.1148/radiol.2303021726
  24. Nakayama Y, Awai K, Funama Y, Liu D, Nakaura T, Tamura Y, et al. Lower tube voltage reduces contrast material and radiation doses on 16-MDCT aortography. AJR Am J Roentgenol 2006;187:W490-W497 https://doi.org/10.2214/AJR.05.0471

Cited by

  1. Multislice CT angiography in coronary artery disease: Technical developments, radiation dose and diagnostic value vol.2, pp.10, 2010, https://doi.org/10.4330/wjc.v2.i10.333
  2. Dual-energy Computed Tomography Imaging of the Aorta vol.25, pp.4, 2009, https://doi.org/10.1097/rti.0b013e3181dc2b4c
  3. Performance Assessment of Four 64-Slice Computed Tomographic Devices for a Typical Clinical Protocol vol.35, pp.1, 2009, https://doi.org/10.1097/rct.0b013e3181f124fe
  4. A systematic review of radiation dose associated with different generations of multidetector CT coronary angiography vol.56, pp.1, 2009, https://doi.org/10.1111/j.1754-9485.2011.02335.x
  5. Coronary CT angiography: current status and continuing challenges vol.85, pp.1013, 2009, https://doi.org/10.1259/bjr/15296170
  6. Low-dose cardiac imaging: reducing exposure but not accuracy vol.10, pp.1, 2009, https://doi.org/10.1586/erc.11.173
  7. Image quality and radiation dose of pulmonary CT angiography performed using 100 and 120 kVp. vol.199, pp.5, 2012, https://doi.org/10.2214/ajr.11.8208
  8. CT Radiation Dose Optimization and Estimation: an Update for Radiologists vol.13, pp.1, 2009, https://doi.org/10.3348/kjr.2012.13.1.1
  9. Radiology Residents' Awareness about Ionizing Radiation Doses in Imaging Studies and Their Cancer Risk during Radiological Examinations vol.13, pp.2, 2009, https://doi.org/10.3348/kjr.2012.13.2.202
  10. Optimization of energy level for coronary angiography with dual-energy and dual-source computed tomography vol.28, pp.4, 2012, https://doi.org/10.1007/s10554-011-9897-z
  11. 흉부 CT촬영에서 저선량 프로토콜의 선량과 화질: 표준선량 프로토콜과 비교 vol.37, pp.2, 2009, https://doi.org/10.14407/jrp.2012.37.2.084
  12. Iterative reconstruction of dual-source coronary CT angiography: assessment of image quality and radiation dose vol.28, pp.7, 2009, https://doi.org/10.1007/s10554-011-0004-2
  13. Impact of iterative reconstruction on CNR and SNR in dynamic myocardial perfusion imaging in an animal model vol.22, pp.12, 2012, https://doi.org/10.1007/s00330-012-2525-z
  14. CT Imaging: Radiation Risk Reduction-Real-Life Experience in a Metropolitan Outpatient Imaging Network vol.9, pp.11, 2012, https://doi.org/10.1016/j.jacr.2012.06.026
  15. Low contrast- and low radiation dose protocol for cardiac CT of thin adults at 256-row CT: usefulness of low tube voltage scans and the hybrid iterative reconstruction algorithm vol.29, pp.4, 2013, https://doi.org/10.1007/s10554-012-0153-y
  16. Effect of kVp on image quality and accuracy in coronary CT angiography according to patient body size: a phantom study vol.29, pp.2, 2009, https://doi.org/10.1007/s10554-013-0298-3
  17. Radiation dose in coronary CT angiography associated with prospective ECG-triggering technique: comparisons with different CT generations vol.154, pp.3, 2009, https://doi.org/10.1093/rpd/ncs243
  18. Endoleak detection after endovascular repair of thoracic aortic aneurysm using dual-source dual-energy CT: suitable scanning protocols and potential radiation dose reduction. vol.200, pp.2, 2009, https://doi.org/10.2214/ajr.11.8033
  19. A study of the dependence of protocol optimization on the left ventricular ejection fraction (LVEF) in coronary CT angiography (CCTA) examination vol.63, pp.8, 2009, https://doi.org/10.3938/jkps.63.1644
  20. Effect of Tube Voltage (100 vs. 120 kVp) on Radiation Dose and Image Quality using Prospective Gating 320 Row Multi-detector Computed Tomography Angiography vol.3, pp.1, 2013, https://doi.org/10.4103/2156-7514.124092
  21. Coronary computed tomography angiography: an overview of clinical applications vol.5, pp.1, 2009, https://doi.org/10.2217/ica.12.79
  22. Image quality of Adaptive Iterative Dose Reduction 3D of coronary CT angiography of 640-slice CT: comparison with filtered back-projection vol.29, pp.3, 2009, https://doi.org/10.1007/s10554-012-0113-6
  23. A Community Hospital's Experience With an Effective, Affordable, and Easily Implemented CT Radiation Dose Reduction Initiative vol.10, pp.5, 2009, https://doi.org/10.1016/j.jacr.2012.10.002
  24. Low radiation dose protocol in cardiac CT with 100 kVp: usefulness of display preset optimization vol.29, pp.6, 2009, https://doi.org/10.1007/s10554-013-0214-x
  25. Image noise-based dose adaptation in dynamic volume CT of the heart: dose and image quality optimisation in comparison with BMI-based dose adaptation vol.24, pp.1, 2009, https://doi.org/10.1007/s00330-013-2980-1
  26. Multidetector Computed Tomography for the Assessment of Adnexal Mass: Is Unenhanced CT Scan Necessary? vol.15, pp.1, 2009, https://doi.org/10.3348/kjr.2014.15.1.72
  27. Comparison of Image Quality of Shoulder CT Arthrography Conducted Using 120 kVp and 140 kVp Protocols vol.15, pp.6, 2009, https://doi.org/10.3348/kjr.2014.15.6.739
  28. Dual-energy computed tomography (DECT) in emergency radiology: basic principles, techniques, and limitations vol.21, pp.4, 2009, https://doi.org/10.1007/s10140-014-1208-2
  29. 진폐요양환자의 흉부 CT촬영에 사용된 선량 - 국내외 진단 참고 준위와 비교 - vol.39, pp.4, 2009, https://doi.org/10.14407/jrp.2014.39.4.206
  30. Image quality and radiation reduction of 320-row area detector CT coronary angiography with optimal tube voltage selection and an automatic exposure control system: comparison with body mass index-ada vol.31, pp.1, 2009, https://doi.org/10.1007/s10554-015-0594-1
  31. A Comparison of the Image Quality and Radiation Dose Using 100-kVp Combination of Different Noise Index and 120-kVp in Computed Tomography Pulmonary Angiography vol.40, pp.5, 2016, https://doi.org/10.1097/rct.0000000000000488
  32. Radiation Dose Reduction at Low Tube Voltage CCTA Based on the CNR Index vol.25, pp.10, 2009, https://doi.org/10.1016/j.acra.2018.01.019
  33. Increasing iterative reconstruction strength at low tube voltage in coronary CT angiography protocols using 3D‐printed and Catphan ® 500 phantoms vol.21, pp.9, 2009, https://doi.org/10.1002/acm2.12977