DOI QR코드

DOI QR Code

Measurements and analysis of the acoustic signals produced by partial discharges in insulation oil

Kil, Gyung-Suk;Kim, Il-Kwon;Park, Dae-Won;Choi, Su-Yeon;Park, Chan-Yong

  • Published : 20090300

Abstract

This paper focuses on the frequency analysis of acoustic signals produced by partial discharges (PDs) in insulation oil and the positioning of the PD occurrence for application in the diagnosis of oil-insulated transformers. Three types of electrode systems; the needle-plane, the plane-plane, and the wire-wire structures were assembled to simulate the partial discharge in insulation oil. A low-noise amplifier and a de-coupler were designed to detect the acoustic signal with high-sensitivity. The frequency ranges of the acoustic signal were 60-270 kHz in the needle-plane electrode system, 45-250 kHz in the plane-plane electrode system, and 50-180 kHz in the wire-wire electrode system. Their peak frequencies were 145 kHz, 118 kHz and 121 kHz, respectively. The position of the PD occurrence was calculated from the time difference of arrival (TOA) using three acoustic emission (AE) sensors. The position was found within a 1% error in the experimental set-up.

Keywords

References

  1. Y.S. Lim, J.Y. Koo, J. Korean. Phys. Soc. 42 (2003) 755
  2. S. Meijer, E. Gulski, P.D. Agoris, P.P. Seitz, T.J.W.H. Hermans, L. Lamballais, IEEE Proc. Prop. Appl. Dielectr. Mater. (2006) 687
  3. T. Leibfried, K. Feser, IEEE Proc. EI (1996) 34
  4. P. Xuzhu Dong, Yilu Liu, F.A. LoPinto, K.P. Scheibe, S.D. Sheetz, IEEE Proc. Power Eng. Soc. Winter Meet. (2002) 701
  5. Y. Kamata, IEEE Trans. EI 21 (1986) 1045
  6. E. Howells, E.T. Norton, IEEE Trans. PAS. 97 (1978) 1538
  7. Gyung-Suk Kil, Jae-Yong Song, Jae-Man Song, Don-Ha Hwang, Dong-Sik Kang, Yong-Ju Kim, J. Korean. Phys. Soc. 49 (2006) 2311
  8. L.E. Lungaard, IEEE Electric. Insul. Mag. 8 (1992) 25
  9. P.J. Harrop, Dielectrics, Butterworth, New York, 1972
  10. M. Yoshizawa, D.H. Yoon, J. Korean. Phys. Soc. 31 (1997) 477
  11. J.P. Steiner, W.L. Weeks, E.S. Furgason, IEEE Proc. Ultrasonics (1984) 938
  12. H. Kawada, M. Honda, T. inoue, T. Amemiya, IEEE Trans. PAS 103 (1986) 1045

Cited by

  1. Location and Identification of Acoustic Signals Recorded in Power Oil Transformers within the Band of 20-180 kHz vol.120, pp.4, 2011, https://doi.org/10.12693/aphyspola.120.709
  2. Analysis of Properties Characteristic for Acoustic Emission Signals Recorded On-Line in Power Oil Transformers vol.120, pp.4, 2011, https://doi.org/10.12693/aphyspola.120.759
  3. Positioning of Partial Discharge Origin by Acoustic Signal Detection in Insulation Oil vol.2, pp.1, 2012, https://doi.org/10.5370/jicee.2012.2.1.028
  4. Frequency Spectrum Analysis of Electromagnetic Waves Radiated by Electric Discharges vol.7, pp.3, 2009, https://doi.org/10.5370/jeet.2012.7.3.389
  5. 모노폴 안테나를 이용한 유중 부분방전의 검출 vol.25, pp.9, 2012, https://doi.org/10.4313/jkem.2012.25.9.727
  6. 절연유중 부분방전 검출을 위한 안테나의 최적 설계 vol.26, pp.4, 2013, https://doi.org/10.4313/jkem.2013.26.4.309
  7. Characteristic Analysis and Origin Positioning of Acoustic Signals Produced by Partial Discharges in Insulation Oil vol.8, pp.6, 2009, https://doi.org/10.5370/jeet.2013.8.6.1468
  8. Partial Discharge Detection Using Acoustic and Optical Methods in High Voltage Power Equipments: A Review vol.845, pp.None, 2009, https://doi.org/10.4028/www.scientific.net/amr.845.283
  9. SF6 가스 중 직류 고전압 하에서 부분방전 특성 vol.27, pp.4, 2014, https://doi.org/10.4313/jkem.2014.27.4.238
  10. Review on partial discharge detection techniques related to high voltage power equipment using different sensors vol.4, pp.4, 2014, https://doi.org/10.1007/s13320-014-0146-7
  11. SF6 압력에 따른 결함별 부분 방전 펄스의 분포 분석 vol.28, pp.1, 2009, https://doi.org/10.4313/jkem.2015.28.1.40
  12. Comparison of Partial Discharge Characteristics in SF6 Gas Under AC and DC vol.16, pp.6, 2009, https://doi.org/10.4313/teem.2015.16.6.323
  13. Optimization of wavelet and thresholding for partial discharge detection under HVDC vol.24, pp.1, 2017, https://doi.org/10.1109/tdei.2016.005969
  14. New diagnosis method of unknown phase-shifted PD signals for gas insulated switchgears vol.25, pp.1, 2018, https://doi.org/10.1109/tdei.2018.006739
  15. Analysis of PD Signal for Condition Monitoring of MV Switchboards by the Measurement of Transient Earth Voltage vol.19, pp.3, 2009, https://doi.org/10.1007/s42341-018-0037-5
  16. Extended Use for the Frequency Response Analysis: Switching Impulse Voltage Based Preliminary Diagnosis of Potential Sources of Partial Discharges in Transformer vol.10, pp.22, 2009, https://doi.org/10.3390/app10228283
  17. Impact of Power Transformer Oil-Temperature on the Measurement Uncertainty of All-Acoustic Non-Iterative Partial Discharge Location vol.14, pp.6, 2009, https://doi.org/10.3390/ma14061385
  18. Experimental Validation for Moving Particle Detection Using Acoustic Emission Method vol.14, pp.24, 2009, https://doi.org/10.3390/en14248516