DOI QR코드

DOI QR Code

A Study for Quality Improvement of Three-dimensional Body Measurement Data

3차원 인체치수 조사 자료의 품질 개선을 위한 연구

  • Park, Sun-Mi (Department of Apparel, Educational Studies, and Hospitality Management, Iowa State University) ;
  • Nam, Yun-Ja (Department of Clothing Textile, Seoul National University) ;
  • Park, Jin-Woo (Department of Applied Statistics, University of Suwon)
  • 박선미 (아이오와주립대학교 의류학과) ;
  • 남윤자 (서울대학교 의류학과) ;
  • 박진우 (수원대학교 통계정보학과)
  • Published : 2009.11.30

Abstract

To inspect the quality of data collected from a large-scale body measurement and investigation project, it is necessary to establish a proper data editing process. The three-dimensional body measurement may have measuring errors caused from measurer's proficiency or changes in the subject's posture. And it may also have errors caused in the process of algorithm expressing the information obtained from the three-dimensional scanner into numerical values, and in the course of data-processing dealing with numerous data for individuals. When those errors are found, the quality of the measured data is deteriorated, and they consequently reduce the quality of statistics which was conducted on the basis of it. Therefore this study intends to suggest a new way to improve the quality of the data collected from the three-dimensional body measurement by proposing a working procedure identifying data errors and correcting them from the whole data processing procedure-collecting, processing, and analyzing- of the 2004 Size Korea Three-dimensional Body Measurement Project. This study was carried out into three stages: Firstly, we detected erroneous data by examining of logical relations among variables under each edit rule. Secondly, we detected suspicious data through independent examination of individual variable value by sex and age. Finally, we examined scatter-plot matrix of many variables to consider the relationships among them. This simple graphical tool helps us to find out whether some suspicious data exist in the data set or not. As a result of this study, we detected some erroneous data included in the raw data. We figured out that the main errors are not because of the system errors that the three-dimensional body measurement system has but because of the subject's original three-dimensional shape data. Therefore by correcting some erroneous data, we have enhanced data quality.

Keywords

References

  1. 남윤자, 최경미, 정의승, 윤명환. Size Korea 3차원 인체측정 방법 표준화, 패션정보와 기술, 1, 6-19, 2004.
  2. 박진우, 박현주, 김진억. 주택가격동향조사를 위한 데이터 편집 사례연구, 조사연구, 6(1), 83-98, 2005.
  3. 산업자원부 기술표준원, 산업기술기반조성에 관한 보고서, 2002.
  4. 산업자원부 기술표준원, 제5차 한국인 인체치수 조사사업 보고서, 2004.
  5. ISO 20686, 3-D Scanning Methodologies for Internationally Compatible Anthropometric Databases, 2005
  6. Granquist. L., Improving the Traditional Editing Process, In Business Survey Methods(eds. Cox et al.), John Wiley &Sons, 177-199, 1995.
  7. Swayne, D. F., Lang, D. T., Buja, A. and Cook, D., GGobi: evolving from XGobi into an extensible framework for interactive data visualization, CSDA, 43, 423-444, 2003. https://doi.org/10.1016/S0167-9473(02)00286-4

Cited by

  1. Analysis of Technical Error of Manual Measurements vol.40, pp.4, 2016, https://doi.org/10.5850/JKSCT.2016.40.4.641