Numerical analysis of shear walls governed by flexural behavior is conducted for the seismic control performance of proposed friction dampers installed at the center of coupling beams. Control effectiveness of shear walls connected by beams with the proposed dampers are compared for single shear wall with same flexural rigidity. Average responses of the shear walls with the dampers are found with seven scaled-downed earthquakes based on KEC 2005 design spectrum. Slip load is the most important design parameter. It is designed to be 5, 10, 20, 30, 60, 90% of total vertical shear force at damper location to prevent damper slip in specific stories. Nonlinear time-history analysis is conducted by using SeismoStruct analysis program. Seismic control performance of the dampers is evaluated for base shear, energy dissipation, curvature and top-floor displacement. Results show that the dampers are the most effective in reducing the responses when their total slip load is 30% of total vertical shear force.

휨거동을 하는 전단벽을 대상으로 동일한 총 단면적을 갖는 1개의 전단벽과 마찰형 감쇠기로 연결된 전단벽의 내진성능을 수치해석을 통해 비교하였다. KBC 2005 설계스펙트럼을 근거로 축소 조절한 7개의 지진파를 입력하중으로 마찰형 감쇠기가 설치된 전단벽의 평균응답을 분석하였다. 마찰형 감쇠기의 중요한 설계변수인 기준 마찰력인 슬립하중은 각층의 마찰형 감쇠기 위치에 생기는 수직방향 전단력의 총합의 5, 10, 20, 30, 60, 90%값으로 하여 슬립이 특정한 층에 편중되지 않도록 하였다. SeismoSturct 프로그램을 이용해 비선형시간이력 해석을 수행하여 밑면 전단력, 에너지 소산량, 1층 벽체곡률, 최상층변위 측면에서 마찰 감쇠기의 제진성능을 분석하였다. 기준마찰력의 30%이하 수준의 총 마찰력을 갖는 마찰 감쇠기가 우수한 제진성능을 보였다.

Keywords

References

  1. 고동우, 이한선 (2007) 1:12축소 비정형 고층 RC 건물의 비선형거동에 대한 실험과 해석의 상관성, 한국지진공학회 논문집, 11(2). pp.95-104 https://doi.org/10.5000/EESK.2007.11.2.095
  2. 박지훈, 김길환 (2007) 에너지 소산형 감쇠기를 이용한 철근 콘크리트 전단벽-골조 시스템의 진동제어, 한국소음진동공학회 춘계학술대회논문집, KSNVE07S-21-03
  3. 장극관, 서대원, 천영수 (2002) 벽식 아파트 구조에서 연결부재의 거동특성, 한국콘크리트학회논문집, 14(1). pp.83-91 https://doi.org/10.4334/JKCI.2002.14.1.083
  4. 장극관, 천영수, 서대원 (2001) 벽식구조 아파트에서 전단벽 연결보의 구조적거동, 한국콘크리트학회 봄 학술발표회논문집, 13(1). pp.411-416
  5. 전대한, 강호근, 조한욱, 이정원 (1998) 정적 탄소성 해석에 의한 고층 벽식 아파트의 수평내력 검토, 한국지진공학회 논문집, 2(4). pp.31-40
  6. 정란, 우성식, 최기영, 박태원 (2007) 기존 철근콘크리트 벽식 공동주택의 내진 성능 예비 평가법에 관한 연구, 한국콘크리트학회 논문집, 19(3). pp.293-300 https://doi.org/10.4334/JKCI.2007.19.3.293
  7. 정희산, 문병욱, 박지훈, 이성경, 민경원, 변지석 (2008) 전단벽식 구조의 휨거동을 이용한 마찰형 감쇠기의 제어성능, 한국소음진동공학회논문집, 18(8). pp.856-863
  8. 홍성걸, 이지형 (2005) 전단벽의 내진보강을 위한 방법에 관한 연구, 한국콘크리트학회 가을 학술발표회논문집, 17(2). pp.25-28
  9. Filippou. F.C .. PoPov. E.G .. Bertero. V.V. (1983) Effects of Bond Deterioration on Hysteretic Behavior of Reinforced Concrete Joints. EERC Report No. UCB/EERC-83/19, Earthquake Engineering Research Center. University of California. Berkeley. Calif.. pp.184
  10. Holden. T .. Restrepo. J .. Mander. J.B. (2003) Seismic Performance of Precast Reinforced and Prestressed Concrete Walls. Journal of structural engineering. 129(3). pp.286-296 https://doi.org/10.1061/(ASCE)0733-9445(2003)129:3(286)
  11. Jennings. P.C .. Housner. G.W .. Tsai. N.C. (1968) Simulated earthquake motions. California Institute of Technology. Pasadena. pp.52
  12. Mander. J.B .. Priestley. J.N .. Park, R. (1989) Theoretical stress-strain model for confined concrete. ASCEJ. Struct. Div. 144(12), pp.1804-1826 https://doi.org/10.1061/(ASCE)0733-9445(1988)114:8(1804)
  13. Martinez-Rueda. J.E.. Elnashai. A.S. (1997) Confined Concrete Model Under Cyclic Load. Materials and structures. 30(197). pp.139-147 https://doi.org/10.1007/BF02486385
  14. Menegotto. M .. Pinto. E. (1973) Method of Analysis for Cyclicallly Loaded Reinforced Concrete Plane Frames Including Changes in Geometry and Non-Elastic Behavior of Elements Under Combined Normal Force and Bending. Proceedings. IABSE Symposium on Resistance and Ultimate Deformability of Structures Acted on by Well-Defined Repeated Loads. Lisbon. pp.15-22
  15. Priestley. M.J.N .. Calvi. G.M .. Kowalsky. M.J. (2007) Displacement-based Seismic Design of Structures
  16. Paulay. T., Priestley. M.J.N. (1992) Seismic Design of Reinforced Concrete and Masonry Buildings. Wiley. New York
  17. SeismoSturct (2002) Earthquake engineering software solution. SeismoSoft Ltd
  18. Soong T.T., Dargush G.F. (1997) Passive Energy Dissipation Systems in Structural Engineering, John Wiley & Sons
  19. Vulcano. A.. Bertero. V.V.. Colotti. v. (1988) Analytical Modeling of RC Structural Walls, Proceedings of the 9th World Conference on Earthquake Engineering. Tokyo-Kyoto. Japan. 6, pp.41-46
  20. Wallace. John W. (1994) New Methodology for Seismic Design of RC Shear Walls. Journal of Structural Engineering. 120(3). pp.863-884 https://doi.org/10.1061/(ASCE)0733-9445(1994)120:3(863)
  21. Xilin Lu. Xiaohan Wu. Liang Meng (1997) Seismic behavior of a new type of seismic energy dissipation shear wall system. Structural Engineering and Mechanics. 5(2). pp.167-175
  22. Xilin Lu. Xiaohan Wu (2000) Study on a new shear wall system with shaking table test and finite element analysis. Earthquake Engineering and Structural Dynamics. 29. pp.1425-1440 https://doi.org/10.1002/1096-9845(200010)29:10<1425::AID-EQE965>3.0.CO;2-A