The Ejector Design and Test for 5kW MCFC System

5kW 용융탄산염 연료전지(MCFC) 이젝터 설계 및 시험

  • Kim, Beom-Joo (Renewable Energy Research Group, Korea Electric Power Research Institute, KEPCO) ;
  • Kim, Do-Hyeong (Renewable Energy Research Group, Korea Electric Power Research Institute, KEPCO) ;
  • Lee, Jung-Hyun (Renewable Energy Research Group, Korea Electric Power Research Institute, KEPCO) ;
  • Lee, Sung-Yoon (Renewable Energy Research Group, Korea Electric Power Research Institute, KEPCO) ;
  • Kim, Jin-Yoel (Renewable Energy Research Group, Korea Electric Power Research Institute, KEPCO) ;
  • Kang, Seung-Won (Renewable Energy Research Group, Korea Electric Power Research Institute, KEPCO) ;
  • Lim, Hee-Chun (Renewable Energy Research Group, Korea Electric Power Research Institute, KEPCO)
  • 김범주 (한전 전력연구원 신재생에너지 그룹) ;
  • 김도형 (한전 전력연구원 신재생에너지 그룹) ;
  • 이정현 (한전 전력연구원 신재생에너지 그룹) ;
  • 이성윤 (한전 전력연구원 신재생에너지 그룹) ;
  • 김진열 (한전 전력연구원 신재생에너지 그룹) ;
  • 강승원 (한전 전력연구원 신재생에너지 그룹) ;
  • 임희천 (한전 전력연구원 신재생에너지 그룹)
  • Published : 2009.02.28

Abstract

An ejector is a machine utilized for mixing fluid, maintaining a vacuum, and transporting fluid. The Ejector enhances system efficiency, are easily operated, have a mechnically simple structure, and do not require a power supply. Because of these advantages, the ejector has been applied to a variety of industrial fields such as refrigerators, power plants and oil plants. In this work, an ejector was used to safely recycle anode tail gas in a 5 kW Molten Carbonate Fuel Cell system at KEPRI(Korea Electric Power Research Institute). In this system, the ejector is placed at mixing point between the anode tail gas and the cathode tail gas or the fresh air. Commercial ejectors are not designed for the actual operating conditions for our fuel cell system. A new ejector was therefore designed for use beyond conventional operating limits. In this study, the entrainment ratio is measured according to the diametrical ratio of nozzle to throat in the designed ejector. This helps to define important criteria of ejectors for MCFC recycling.

Keywords

References

  1. H. El-Dessouky, H.Ettouney, I. Alatiqi, G. Al-Nuwaibit, 'Evaluation of steam jet ejectors', Chemical Engineering and Processing 41 (2002) 551-561 https://doi.org/10.1016/S0255-2701(01)00176-3
  2. Y. Zhu, W. Cai, C. Wen, Y. Li, 'Fuel ejector design and simulation model for anodic recirculation SOFC system', Journal of Power Sources 173(2007) 437-449 https://doi.org/10.1016/j.jpowsour.2007.08.036
  3. Keenan, J.H., Neumann, E.P. and Lustwerk. F., 'An Investigation of Ejector Design by Analysis and Experiment', Journal of Applied Mechanics. Vol. 17, No. 3, 1950, pp. 299-309
  4. M.T.Kandakure, V.G. Gaikar, A.W. Patwardhan, 2005, 'Hydrodynamic aspects of ejectors', Journal of Chemical Engineering Science 60 (2005) 6391-6402 https://doi.org/10.1016/j.ces.2005.04.055
  5. R.Yapici, H.K. Ersoy, 2005, 'Performance charateristics of the ejector refrigeration system based on the constant area ejector flow model', Journal of Energy Convertsion & Management 46 (2005) 3117-3135 https://doi.org/10.1016/j.enconman.2005.01.010
  6. Heat Exchanger Institute, Standards for steam jet vacuum systems, 1988, 4th edition