DOI QR코드

DOI QR Code

Personal Exposure Level of Nitrogen Dioxide in an Industrial Area

일부 공단지역 내 이산화질소에 의한 개인노출 농도에 관한 연구

  • Jeon, Yong-Teak (Soonchunhyang University Graduate School of Environment Health Science) ;
  • Yang, Won-Ho (Dept. of Occupational Health, Catholic University of Daegu) ;
  • Cho, Tea-Jin (Soonchunhyang University Graduate School of Environment Health Science) ;
  • Son, Bu-Soon (Soonchunhyang University Graduate School of Environment Health Science)
  • 전용택 (순천향대학교 환경보건학과) ;
  • 양원호 (대구카톨릭대학교 산업보건학과) ;
  • 조태진 (순천향대학교 환경보건학과) ;
  • 손부순 (순천향대학교 환경보건학과)
  • Published : 2009.02.28

Abstract

This study was conducted in industrial area. The level of nitrogen dioxide was measured indoor, outdoor, work and personal in an study area within 5 km from source of pollution and control area 15 km farther from August, 2006 to September. The followings are the summary of this research. The concentration of the indoor and the outdoor $NO_2$ levels in the industrial area are 18.41$\pm$6.35 ppb, 18.51$\pm$3.26 ppb each, and the indoor/outdoor concentration rate is 0.99. The concentration of $NO_2$ in the workplace is 18.59$\pm$10.16 ppb, and the individual exposure rate is 18.80$\pm$5.71 ppb. The concentration of the indoor and the outdoor $NO_2$ levels control area are 12.57$\pm$3.82 ppb, 9.68$\pm$2.16 ppb each, and the indoor/outdoor concentration rate is 1.33. The personal exposure rate is 14.49$\pm$10.06 ppb. The residents of the each area and those of the comparative area spend 80.9% and 76.9% each their time in the indoor. It shows they spend most of their time in indoor. The predictions of the individual exposure rates in the industrial area and the comparative area are 15.10$\pm$6.14 ppb and 10.52$\pm$3.82 ppb each, The concentration levels measured by passive sampler are 18.80$\pm$5.71 ppb and 14.49$\pm$10.34 ppb each. The result of the research is the analysis of the personal exposure rate in indoor, outdoor and workplace of industrial area. This research may bo used as a basic data to manage and to establish the plan for $NO_2$ gas of the industrial area.

Keywords

References

  1. Ministry of Environment, Risk assessment and management of air pollutant, 1998
  2. Kim, Y. S. and Yanagisawa, Y. : Personal, Indoor and Outdoor NO, Measurements in an Urban Area. Korean Journal of Environmental Health, 3(2), 33-38, 1987
  3. Yang, W. H .. Bae, H. J., Kim. H. Y., Jung, M. S.,and .Tung, M. H. : A study on concentration of indoornitrogen dioxide in relation to hOllse characteristics. Korean Journal of Sanitation, 14(4), 85-92, 1999
  4. WHO, Air quality guidelines for Europe. WHO Rub. European Series Vol. 23, 1987
  5. Lee, J. T., Shin, D. C. and Chung, Y. : Air pollution and daily mortality in Seoul and U1san. Korea, Environmental Health Perapectines, 107(2), 149-154. 1999 https://doi.org/10.2307/3434372
  6. Spengler, J. D., Schwab, M,. McCermott, A., Lambert, W. E. and Samet, J. M. : Nitrogen dioxide and respiratory illness in children. Part IV: Effect of housing and meteorologic factors on indoor nitrogen dioxideconcentrations. Research Report-Health Effects Institute, 58, 1-29. 1996
  7. Nielson, O. R., Skov, H., Lohse, C, Thomas, B. L. and Olsen, 1. H. : Front-door concentrations and personal exposure of danish children to nitrogen dioxide. Environmental Health Perspectives, 105(9), 964-970, 1997 https://doi.org/10.2307/3433877
  8. UNEP/WHO, Passive and Active sampling Methodologies for Measurement of Air Quality, GEMS/AIR Methodologies Review Handbook Series, 14, UNEP, Nairobi, 1995
  9. Yanagisawa, Y. and Nishmura, H. : A badge-type personal sampler for measurement of personal eaposure to NO, and NO in ambient air. Environment intermational, 8, 235-242, 1982 https://doi.org/10.1016/0160-4120(82)90033-2
  10. 양원호, 이기영, 백도명: 실내 및 실외 공기중 이산화 질소의 개인노출량 측정을 위한 수도식 시료채취기의 성능평가. 대기환경학회지, 16(6), 625-631, 2000
  11. Yang, W.-H., Lee, S.-H. and Paek, D.-M. : Exposure assessment and estimation of personal exposure for nitrogen dioxide using time weighted average model. Journal of Korea Public Health Association, 17(3), 251-258, 2001
  12. Christopher, Y. H. and Chao, A. L. : A study of personal exposure to nitrogen dioxide using passive samplers. Building and Environment, 35, 533-545, 2000
  13. Cbo, J., Park, .T.-A., Son, B.-S. and Yang, W.-H. :Effeet of residential air quality in accordance with dispersion of nitrogen dioxide from line sources on the road. Journal of Korea Public Health Association, 28(4), 373-379, 2002
  14. Kim, W.-J. : A study on property of nitrogen dioxidc concentration using passive sampler in industrial areas. Master's degree, Department of Environmental Engineering, Han Yang University, Seoul, 2000
  15. Jung, S.-W. : A study of risk assessment and indoor air quality assessment of N02 and VOCs in apartments, Master's degree, Department of Environment Health, Soonchunhyang University, A-San, 2005
  16. Levy, J. I., Lee, K., Spengler, J. D. and Yanagisawa, Y. : Tmpact of residential nitrogen dioxide exposure on personal exposure: An intel1lational study. journal of the Air & Waste Management Association, 48(6), 553-560, 1998 https://doi.org/10.1080/10473289.1998.10463704
  17. Bang, Y. N .. Son, B. S., Yang, W. H., Park, J. A. and Jang, B. K. : Estimation of exposure to nitrogen dioxide ill profe,sional drivers using lime activity pattern. Korea Journal of Environmental Health Society, 27(1), 22-26, 2001
  18. Kim, Y. S. and Cho, B. A. : Indoor and outdoor NO, measurements in homes. journal If Korean Society for Atmospheric Environment, 1, 189-190, 1996
  19. Dimitroulopoulou, C., Ashmore, M. R., Byrne, M. A. and Kinnersley, R. P. Modeling of indoor exposure on personal exposure to nitrogen dioxide. Atmospheric Environment, 35, 269-279, 2001 https://doi.org/10.1016/S1352-2310(00)00176-X
  20. Ministry of Environment, Exposure Factor Handbook, 2001

Cited by

  1. Estimating Personal Exposures to Air Pollutants in University Students Using Exposure Scenario vol.22, pp.1, 2013, https://doi.org/10.5322/JES.2013.22.1.47