Application of Low-Dose CT for Screening of Lung Disease

폐질환의 선별검사를 위한 저선량 전산화 단층촬영의 적용

  • Lee, Won-Jeong (Team of Clinical Research, Center for Occupational Lung Diseases, K-medi) ;
  • Choi, Byung-Soon (Team of Clinical Research, Center for Occupational Lung Diseases, K-medi) ;
  • Park, Young-Sun (Department of Radiological Technology, Daejeon Health Sciences College) ;
  • Seon, Jong-Ryul (Department of Radiological Technology, Daejeon Health Sciences College) ;
  • Bae, Seok-Hwan (Department of Radiogical Science, Konyang University)
  • 이원정 (한국산재의료원 직업성폐질환연구소 임상연구팀) ;
  • 최병순 (한국산재의료원 직업성폐질환연구소 임상연구팀) ;
  • 박영선 (대전보건대학 방사선과) ;
  • 선종률 (대전보건대학 방사선과) ;
  • 배석환 (건양대학교 방사선학과)
  • Published : 2009.06.30

Abstract

As CT has been increasingly used as an accurate screening tool for lung disease, radiation dose becomes an important issue for both radiographers and patients. Many researches have been done for a low-dose CT as a screening tool for early detection of asymptomatic lung diseases. From those studies, it has been reported that chest dose rate from the low-dose CT is considerably lower than from standard CT. The patient dose is determined by scanning parameters such as kVp, mAs, pitch, scan time and the radiation risk of lung in screening examination may not be negligible. Herein, we suggest that Low-dose CT is useful as a screening tool in routine clinical practice on the basis of published articles, but further study is necessary because Low-dose CT has poor sensitivity and specificity for screening early stage of lung cancer according to the results of the studies. This article is to provide a brief overview of the screening examinations by Low-dose CT.

전산화 단층촬영은 폐질환의 정밀진단 방법으로 사용이 증가되고 있다. 통상적으로 시행되는 CT촬영은 조기 진단을 위한 선별검사로써는 높은 방사선 노출과 고비용, 조영제 사용으로 인한 부작용 등으로 적당하지 않다. 영상의학분야에서 방사선을 이용한 CT촬영은 진단 능력이 우수한 반면 피폭선량 또한 매우 높아 선량 감축을 위한 노력이 절실하다. 그동안 많은 연구들에서 무증상기의 폐암 및 폐질환을 조기 발견하기 위한 선별검사로써 저선량 CT의 유용성에 대해 이루어져 왔고, 의미있는 결과를 보고하였다. 선량 감소에 많은 인자가 관여하고 있지만 조사선량(mAs)의 감소가 가장 많이 사용되고 있다. 이미 보고 된 많은 연구에서 저선량 CT는 폐질환을 조기 발견하기 위한 선별검사로써 임상에서 사용하기에 유용하지만, 일부 연구에서 조기 폐암을 예측할 수 있는 작은 결절을 발견하는데 낮은 민감도와 특이도를 보였고, 실제 생존율 증가에는 기여하지 못한 보고도 있었다. 따라서, 지금까지의 저선량 CT에 대한 연구결과를 토대로 다양한 위험에 노출된 집단을 대상으로 선량을 감소시키기 위한 연구가 계속적으로 이루어진다면, 향후 저선량 CT촬영은 폐암을 비롯한 폐질환의 조기진단 방법으로써 통상적으로 사용되고 있는 표준 CT촬영을 충분히 대체할 수 있을 것으로 전망한다.

Keywords

References

  1. Otto HW : Whole Body Computed Tomography Second Edition Chapter 2 Techniques of Computed Tomography, Blackwell Scientific Publications, 1-9, 1992
  2. ICRP : Managing Patient Dose in Computed Tomography, Publication 87, 2000
  3. Diederich S, Wormanns D, Heindel W : Lung cancer screening with low-dose CT, European Journal of Radiology, 45, 2-7, 2003 https://doi.org/10.1016/S0720-048X(02)00302-9
  4. 강은영 : 흉부 MDCT의 임상적 이용, 제 18차 대한 결핵 및 호흡기학회 Workshop, 17-22, 2003
  5. Goo JM : Computer-Aided Diagnosis in Chest CT, Tuberculosis and Respiratory Diseases, 57(6), 515-521, 2004 https://doi.org/10.4046/trd.2004.57.6.515
  6. Naidich DP, Marshall CH, Gribbin C, Arams RS, McCauley DI : Low-dose CT of the lungs : preliminary observations, Radiology, 175, 729-731, 1990 https://doi.org/10.1148/radiology.175.3.2343122
  7. Kaneko K, Eguchi K, Ohmatsu H, et al : Peripheral lung cancer : screening and detection with low-dose spiral CT versus radiology, Radiology, 201, 798-802, 1996 https://doi.org/10.1148/radiology.201.3.8939234
  8. Li F, Sone S, Abe H, MacMahon H, Doi K : Low-Dose Computed Tomography Screening for Lung Cancer in a General Population : Characteristics of Cancer in Non-Smokers Versus Smokers, Acad Radiol, 10, 1013-1020, 2003 https://doi.org/10.1016/S1076-6332(03)00150-8
  9. Manser R, Dalton A, Carter R, Byrnes G, Elwood M, Campbell DA : Cost-effectiveness analysis of screening for lung cancer with low dose spiral CT(computed tomography) in the Australian setting, Lung cancer, 48, 171-185, 2005 https://doi.org/10.1016/j.lungcan.2004.11.001
  10. Sons S, Takashima S, Li F, et al : Mass screening for lung cancer with mobile spiral computed tomography scanner, Lancet, 351, 1242-1245, 1998 https://doi.org/10.1016/S0140-6736(97)08229-9
  11. Henschke CI, McCauley DI, Yankelevitz DF, et al : Early lung cancer action project : overall design and findings from baseline screening, Lancet, 354, 99-105, 1999 https://doi.org/10.1016/S0140-6736(99)06093-6
  12. Karabulut N, Ariyurek M : Low dose CT: practices and strategies of radiologists in university hospitals, Diagn Interv Radiol, 12(1), 3-8, 2006
  13. Theocharopoulos : Estimation of effective doses to adult and pediatric patients from multislice computed tomograpphy : A method based on energy imparted, Med Phys, 33(10), 3846-3856, 2006 https://doi.org/10.1118/1.2349694
  14. Rydberg J, Liang Y, Teague SD : Fundamentals of multichannel CT, Radiol Clin North Am, 41, 465-74, 2003 https://doi.org/10.1016/S0033-8389(03)00029-0
  15. ICRP : Managing patient dose in digital radiography, publication 93, 2003
  16. Kalender WA : Computed Tomography. John Wiley and Sons, New York, NY. 2000
  17. Prasad S, Wittram C, Shepard JA, McLoud T, James R : Standard-dose and 50%-reduced-dose chest CT : Comparing the effect on image quality. AJR, 179, 46-465, 2002
  18. Muller NL, Miller RR : Computed tomography of chronic diffuse infiltrative lung disease, Am Rev Respir Dis, 142, 1206-1215, 1990 https://doi.org/10.1164/ajrccm/142.5.1206
  19. Murata K, Khan A, Rojas KA, Herman PG : Optimization of computed tomography technique to demonstrate the fine structure of the lung, Invest Radiol, 23, 170-175, 1988 https://doi.org/10.1097/00004424-198803000-00003
  20. Remy-Jardin M, Sobaszek A, Duhamel A, Mastora I, Zanetti C, Remy J : Asbestos-related Pleuropulmonary Disease : Evaluation with Low-Dose Four-Detector Row Spiral CT, Radiology, 233, 182-190, 2004 https://doi.org/10.1148/radiol.2331031133
  21. CEC : Quality Criteria for Computed Tomography, European Guidelines. EUR 16262, Commission of the European Communities, Luxembourg 1999
  22. 곽성섭, 장지열, 강성호, 노원규, 신현길, 황윤천 : LUNG의 HRCT에 관한 검토. '94 GE CT USER SEMINAR, 1994
  23. Hwang JH : Lung Cancer Screening with Lowdose Computed Tomography, Tuberculosis and Respiratory Diseases, 57(2), 118-124, 2004 https://doi.org/10.4046/trd.2004.57.2.118
  24. Jung KJ, Lee KS, Kim SY, Kim TS, Pyeun YS, Lee JY. Low-dose, Volumetric Helical CT : Image Quality, Radiation Dose, and Usefulness for Evaluation of Bronchiectasis. Invest Radiol, 35(9):557-563, 2000 https://doi.org/10.1097/00004424-200009000-00007
  25. 최요원 : 진폐증의 중증도 진단에서(Low-Dose) chest CT의 적용가능성, 2007년도 영상의학워크숍, 1, 11-29, 2007
  26. Mayo JR, Hartman TE, Lee KS, Primack SL, Vedal S, Muller NL : CT of the chest : minimal tube current required for good image quality with the least radiation dose, Am J Roentgenol, 164(3), 603-7, 1995 https://doi.org/10.2214/ajr.164.3.7863879
  27. Lee KS, Primack SL, Staples CA, Mayo JR, Aldrich JE, Muller NL : Chronic infiltrative lung disease : comparison of diagnostic accuracies of radiography and low- and conventional-dose thin-section CT, Radiology, 191(3), 669-73, 1994 https://doi.org/10.1148/radiology.191.3.8184044
  28. Frost JK, Ball WC, Levin ML et al. Early lung cancer detection ; Results of the initial (prevalence) radiologic and cytologic screening in the Johns Hhopkins study. Am Rev Respir Dis, 130:549-554, 1984
  29. Melamed MR : Lung cancer screening results in the National Cancer Institute New York study, Cancer, 89, 2356-2362, 2000 https://doi.org/10.1002/1097-0142(20001201)89:11+<2356::AID-CNCR8>3.0.CO;2-Z
  30. Soda H, Tomita H, Kohno S, Oka M : Limitation of annual screening chest radiography for the diagnosis of lung cancer, Cancer, 72, 2341-2346, 1993 https://doi.org/10.1002/1097-0142(19931015)72:8<2341::AID-CNCR2820720809>3.0.CO;2-A
  31. Roach HD, Davies GJ, Attanoos R, Crane M, Adams H, Phillips S : Asbestos: when the dust settles-An imaging review of asbestos-related disease, RadioGraphics, 22, S167-S184, 2002 https://doi.org/10.1148/radiographics.22.suppl_1.g02oc10s167
  32. Gierada DS, Pilgram TK, Whiting BR, et al : Comparison of standard and low radiation dose CT for quantification of emphysema, AJR, 188, 42-47, 2007 https://doi.org/10.2214/AJR.05.1498
  33. Kubik A, Polak J. Lung cancer detection. Results of a randomized prospective study in Czechoslovakia. Cancer, 57:2427-2437 1986 https://doi.org/10.1002/1097-0142(19860615)57:12<2427::AID-CNCR2820571230>3.0.CO;2-M