In this paper, remote monitoring system for wind turbine site is developed. This system is a hierarchical reliable monitoring system connected by wireless communication channels between monitoring host computer and modular slave measuring subsystems. The design of this systems; the slave measuring subsystems is placed in meteorological tower and wind turbine, and the supervisory host computer is in the safety zone. The slave measuring subsystems signals are from a meteorological tower, wind turbine generator and tower. For monitoring and command function, the supervisory computer is implemented with a PC using graphic user interface. This system can be transferred the information among host computer and remote computers through the Ethernet. Consequently we can get reliability but economic system. The system has the concept of universality and modularity, so it is simple and easy to implement in wind turbine test sites.

Keywords

References

  1. Byun, H. I., Ryu, J. Y. and Kim, D. H., 'The Study ofthe Wind Resource and Energy Yield Assessment for he Wind Park Development,' J. of The Korean Society for New and Renewable Energy, Vol. 1, No.2, pp. 19-25, 2005
  2. Chung,C.W.,Sohn,Y.U.Son,J.B.,Park,I.S.,Kim,Y.C.,KimK.R.,Kwon,S.J.and Chun, C.H., 'Design of a 750kW direct drive wind turbine generator system,' WWEC, pp. 1-4, 2004
  3. Yoo, N. S., Kim, S. H., Nam, Y. S. and Lee, J. W.,'Wind Turbine Certification Research for the Daekwanryung Test Site,' Korean Wind Energy Conference, pp. 32-36, 2002
  4. Nam, Y. S., Yoo, N. S. and Lee, J. W., 'SiteCalibration for the Wind Turbine PerformanceEvaluation,' Journal of Mechanical Science andTechnology, Vol. 18, No. 12, pp. 2250-2257, 2002
  5. Kim, S. H., Nam, Y. S., Yoo, N. S., Park, M. Y., Kim,T. H. and Park, H. G., 'Vibration PerformanceMonitoring of a 1kW Small Wind Turbine Generator,' Journal of Industrial Technology,Kangwon National Univ., No. 26A, pp. 68-72, 2006
  6. Nam, Y. S., Kim, H. G., Yoo, N. S. and Lee, J. W.,'Development of a Wind Turbine Monitoring Systemusig Labview,' Journal of Korean Society forPrecision Engineering, Vol. 20, No, 5, pp. 134-139 2003
  7. NRG Systems Inc., 'Symphonie Data Logger and Accessories : User Manual,' NRG Systems Inc., 1996
  8. IEC, 'Technical specification IEC TS 61400-13, Wind Turbine generator system-Part13: Measurement of mechanical loads,' IEC, pp. 19-28, 2001
  9. Initium Promi-SD User Guide, 'Bluetooth, Rs232C Serial Dongle,' Initium, 2005
  10. ATMEL, 'ATmega128, 8-bit AVR Microcontroller with 128K Bytes In-System Programmable Flash,' ATMEL, 2006