DOI QR코드

DOI QR Code

A Comparative Analysis of the Difference between 3D Body Scan Measurements and Physical Measurements by Gender -5th Size Korea Adult Data-

3차원 스캔측정치와 직접치수간 차이의 성별 비교 -제5차 Size Korea 성인데이터를 대상으로-

  • Han, Hyun-Sook (Research Institute of Human Ecology, Seoul National University) ;
  • Nam, Yun-Ja (Research Institute of Human Ecology, Seoul National University)
  • 한현숙 (서울대학교 생활과학연구소) ;
  • 남윤자 (서울대학교 생활과학연구소)
  • Published : 2009.08.31

Abstract

A 3D body scan measurement (SM) is used as an alternative to physical measurements (PM) as the information for designing industrial products. This study compared the mean difference (MD) between SM and PM by gender and analyzed the causes of the difference. The data used in this study were the scan measurements and physical measurements of adults aged twenty to seventy years old of the fifth Size Korea survey. The results of this study are as follows: 1. The comparison of MD between men and women for all subjects: The measurement of the significant differences between men and women were height, neck base girth, chest girth, under-bust girth, waist girth, armscye girth, back length, and foot length. The causes of difference are the difference of body shape. 2. The comparison of MD between men and women by BMI groups: Many measurements had significant differences between men and women at normal weight and overweight but underweight. Some measurements had significant differences only at a specific BMI group because the body shape difference between men and women is revealed clearly in the group. The comparison of MD between men and women by age groups: The measurements that show significant difference at more than four age groups were neck girth, chest girth, under-bust girth, waist girth, armscye girth, and foot length. The height and abdomen girth had a significant difference in the age range of 20's and 30's. There were measurements that increase MD with an increase in age; under-bust girth and lateral shoulder length for women and lateral shoulder length for men. This comparison of MD between men and women provide the correct guidelines for the use of SM.

Keywords

References

  1. 김명수, 남윤자. (2002). 3차원 인체형상데이터 관리 및 정보화 시스템 개발. 과천: 산업자원부 한국표준협회
  2. 남윤자, 최경미, 정의승, 윤명환. (2002). 3차원 인체측정법 표준화. 과천: 산업자원부 한국표준협회
  3. 남윤자, 최경미, 정의승, 윤명환. (2003). 3차원 인체측정프로토콜. 과천: 산업자원부 한국표준협회
  4. 남윤자, 최경미, 정의승, 윤명환. (2004), Size Korea 3차원인체측정방법 표준화, 패션정보와 기술, 1, 6−19
  5. 백경자, 이정란. (2008), 3차원 바디 스캐너를 이용한 남성 상반신 인체측정-직접측정과의 비교, 한국의류학회지, 32(1),21−34
  6. 한현숙, 남윤자. (2001), 의복제작을 위한 인체자동측정알고리즘에 관한 연구, 한국섬유공학회지, 38(9), 478−86
  7. Mckinnon, L., & Istook, C. L. (2001), Comparative analysis of the image twin system and the 3T6 body scanner. Journal of Textile and Apparel Technology and Management,1(2), 1−7
  8. Mckinnon, L., & Istook, C. L. (2002). The effects of subject respiration and foot positioning on the data integrity of scanned measurements. Journal of Fashion Marketing and Management, 6(2), 103−121 https://doi.org/10.1108/13612020210429458
  9. Robinette, K. M., & Daanen, H. A. (2006). Precision of the CAESAR scan-extracted measurements. Applied Ergonomics, 37(3), 259−265 https://doi.org/10.1016/j.apergo.2005.07.009

Cited by

  1. Domestic Research Trends in IT Fashion vol.14, pp.4, 2012, https://doi.org/10.5805/KSCI.2012.14.4.614