Abstract

This paper describes a robust mobile u-healthcare system with multiple physiological signs measurement capability in real time with integration of WSN(wireless sensor network) technology and CDMA(code division multiple access) network. A cellular phone receives health data in WSN and performs local physiological signs analysis at a phone processor, and then transmits abnormal data to server for further detail or precise health signal evaluation by a medical doctor over a CDMA network. Physiological signs of the patients are continuously monitored, processed and analyzed locally at cellular phone process to produce useful medical information for diagnosis and tracking purposes. By local simple analysis in cellular phone processor we can save the data transmission cost in CDMA network. By using the developed integrate ubiquitous healthcare service architecture, patients can realize self-health checking so that the prevention actions can be taken earlier. Appropriate self-monitoring and self-management can cure disease and relieve pain especially for patients who suffer from chronic diseases that need long term observation.

Keywords

References

  1. Department of Economic and Social Affairs Population Division, 'World population ageing: 1950-2050', Available at: http://www.un.org/esa/population/publications/worldageing19502050/pdf/preface_web.pdf, 2001
  2. 이대석, 정완영, 'QRS검출에 의한 ECG분석 기능을 갖춘 무선센서노드를 활용한 u-헬스케어 시스템, 센서학회지', 제16권, 제5호, pp. 361-368, 2007 https://doi.org/10.5369/JSST.2007.16.5.361
  3. A. Takeuchi, K. Kobayashi, N. Mamorita, and N. Ikeda, 'A cell phone-based diary for chronic diseases', The 4th IET International Conference on Advances in Medical, Signal and Information Processing MEDSIP 2008, Santa Margherita Ligure, Italy, pp. 1-4, 2008
  4. K-S. Park, N-J. Kim, J-H. Hong, M-S. Park, E-J. Cha, and T-S. Lee, 'PDA based point-of-care personal diabetes management system', IEEE-EMBS 2005, Shanghai, China, pp. 3749-3752, 2005
  5. J. Pan And WJ. Tompkins, 'A real-time QRS detection algorithm', IEEE Transactions on Biomedical Engineering, vol. BME-32, No. 3, pp. 230-236, 1985 https://doi.org/10.1109/TBME.1985.325532
  6. Department of Health & Human Services, 'High blood pressure'. Available at: http://www.nhlbi.nih.gov/health/dci/Diseases/Hbp/HBP_WhatIs.html, 2008
  7. 이승철, 이영동, 정완영, '실내환경 모니터링시스템을 위한 무선 센서네트워크에서의 플러딩 방식의 질의모델 설계 및 구현', 센서학회지, 제17권, 제3호, pp. 168-177, 2008 https://doi.org/10.5369/JSST.2008.17.3.168
  8. S. Bhardwaj, G. Walia, R. Myllylae and W-Y. Chung, 'Query based ecg monitoring and analyzing system via wireless sensor network', In proc. of the 2nd International Conf. on Wireless Communication & Sensor Networks, Allahabad, India, pp. 146-153, 2006

Cited by

  1. A Research for Removing ECG Noise and Transmitting 1-channel of 3-axis Accelerometer Signal in Wearable Sensor Node Based on WSN vol.20, pp.2, 2011, https://doi.org/10.5369/JSST.2011.20.2.137
  2. Priority Based Multi-Channel MAC Protocol for Real-Time Monitoring of Weapon Flight Test Using WSNs vol.22, pp.1, 2013, https://doi.org/10.5369/JSST.2013.22.1.18