Vibration Characteristics of a Three-Story Reinforced Concrete Building Before and After Damage

3층 철근콘크리트조 건물의 손상전후의 진동특성

  • 윤성원 (서울산업대학교 건축학부) ;
  • 박용 (서울산업대학교 대학원 건축학과) ;
  • 지정환 (서울산업대학교 대학원 건축학과) ;
  • 임재휘 (서울산업대학교 대학원 건축학과) ;
  • 장동우 (서울산업대학교 대학원 건축학과)
  • Published : 2009.09.15

Abstract

Dynamic characteristics such as frequency and damping ratio in the ambient state of building has been progressed in domestic and foreign. However, there has not been any deep research of dynamic characteristics of full-scale structure using vibration measurement of the building damaged up to failure. Dynamic characteristics of three-story reinforced concrete building was evaluated before and after it was damaged by using a actuator. Dynamic characteristics is reviewed and compared with previous study. Ambient vibration and human excitation test were applied. After 120mm horizontal displacement by actuator, frequency of long and short direction is reduced to 34.3%, 33.7% and damping ratio is reduced to 36.5%, 19.5% respectively.

구조물이 건전한 상태에서 진동계측을 통한 고유진동수와 감쇠율과 같은 동적특성의 분석에 대하여 국내 외적으로 많은 연구가 진행되어 왔다. 그러나 실물 구조물에 대하여 파괴 직전까지의 큰 손상 후에 진동계측을 통한 동적특성에 대한 연구는 상대적으로 매우 미약한 실정이다. 따라서 본 연구는 3층 철근콘크리트조 건물에 엑츄에이터로 하중을 주어 건물에 손상을 준 후에 손상 전 후의 진동계측을 통하여 동적특성을 파악하였다. 손상 전 후에 대한 고유진동수 및 감쇠율을 산정하였으며, 이 결과를 국외의 기존 연구와 비교하였다. 상시진동계측 및 인력가진을 통한 계측방법을 실시하였으며, 계측 전에 고유치 해석을 선행하여 계측치와 비교분석을 하였다. 120mm의 수평변위를 준 결과 구조물의 파괴 직전 손상 전 후에 장변과 단변의 고유진동수는 각각 34.3%, 33.7% 감소하였고, 감쇠율은 각각 36.5%, 19.5% 감소하였다. 기존 국외의 연구결과와의 비교를 한 결과 고층형 건물보다 강성의 변화가 크게 감소됨을 확인할 수 있었으며, 저층형 구조물에 대한 안정성 검토가 시급함을 확인할 수 있다.