Abstract

Recently, NDTs (Non-Destructive Techniques) using infrared camera are widely studied for detection of damage and void in RC (reinforced concrete) structures and they are also considered as an effective techniques for maintenance of infrastructures. The temperature on concrete surface depends on material and thermal properties such as specific heat, thermal conductivity, and thermal diffusion coefficient. Different porosity on cement mortar due to different mixture proportions can show different heat behavior in cooling stage. The porosity can affect physical and durability properties like strength and chloride diffusion coefficient as well. In this paper, active thermography which uses flash for heat induction is utilized and thermal characteristics on surface are evaluated. Samples of cement mortar with W/C (water to cement ratio) of 0.55 and 0.65 are prepared and physical properties like porosity, compressive strength, and chloride diffusion coefficient are evaluated. Then infrared thermography technique is carried out in a constant room condition (temperature $20{\sim}22^{\circ}C$ and relative humidity 55-60%). The mortar samples with higher porosity shows higher residual temperature at the cooling stage and also shows reduced critical time which shows constant temperature due to back wall effect. Furthermore, simple equation for critical time of back wall effect is suggested with porosity and experimental constants. These characteristics indicate the applicability of infrared thermography as an NDT for quality assessment of cement based composite like concrete. Physical properties and thermal behavior in cement mortar with different porosity are analyzed in discussed in this paper.

최근 들어 적외선을 이용하여 콘크리트 구조물의 결함 또는 공동 등을 평가하려는 비파괴 연구가 활발하게 진행되고 있으며, 이는 유지관리기법의 중요한 부분을 이루고 있다. 적외선 화상분석(Infrared Thermography)을 콘크리트 표면에 적용할 경우, 콘크리트의 표면온도는 표면을 구성하는 재질과 열적특성(비열, 열전도율, 열전달율)에 따라 그 응답이 다르게 나타나게 된다. 서로 다른 배합을 가지는 시멘트 모르타르에서는 공극률이 다르게 구성되고, 표면에서 공극률의 차이는 열에 노출된 뒤, 냉각되는 과정에서 열적 거동이 다르게 평가된다. 한편 이러한 공극률은 강도 및 염화물 확산계수와 같은 역학적/내구적 특성에 영향을 주기도 한다. 본 연구에서는 외부에서 열을 가하여 측정하는 능동방식(active type)을 이용하여, 표면의 온도변화를 분석하였다. 물-시멘트비 55%와 65%인 시멘트 모르타르 시편을 제작하였으며, 공극률, 압축강도, 염화물 확산계수 등의 물리적 특성값들이 평가되었다. 이후 동일한 실내조건(온도 $20{\sim}22^{\circ}C$, 습도 55-60%)에서 적외선 화상분석 기법을 적용하였다. 시간의 경과에 따라 공극을 많이 포함하는 시편의 경우, 표면 온도가 상대적으로 증가하였으며, 온도가 일정해지는 시점(임계시점)이 단축되고 있음을 확인할 수 있었다. 이러한 특성은 콘크리트와 같이 공극과 골재를 가지고 있는 복합재료의 품질 평가에 적용할 수 있음을 시사한다. 한편 공극률과 실험상수를 고려하여, 공극률에 따라 변화하는 임계시간에 대한 계산식을 제안하였다. 본 논문에서는 시멘트 모르타르의 공극량의 변화에 따른 물리적 변화와 이에 따른 열특성 변화가 논의될 것이다.

Keywords

References

  1. 박상순, 권성준, 김태상(2009) 시멘트 모르타르의 공극률과 내구 특성과의 관계에 대한 실험적 연구, 대한토목학회 논문집, 대한토목학회, 제29권, 제2A호, pp. 171-179.
  2. 박석균(2003) 레이더법과 적외선 법을 이용한 콘크리트 시공 이음부 공극의 비파괴 검사, 한국콘크리트학회 논문집, 한국콘크리트학회, 제15권, 제3호, pp. 425-432.
  3. 송하원, 권성준, 변근주, 박찬규(2005) 혼화재를 사용한 고성능 콘크리트의 배합특성을 고려한 염화물 확산 해석기법에 관한 연구, 대한토목학회 논문집, 대한토목학회, 제25권, 제1A호, pp. 213-223.
  4. 심준기, 지광습, 이종세(2008) 근적외선과 열화상 기법을 이용한 콘크리트 내부 공극 검출, 한국콘크리트학회 봄 학술발표회, 한국콘크리트학회, pp. 1021-1024.
  5. 윤영호, 전명훈, 박지영, 이정민, 정란(2003) 인공공동 시험제를 이용한 적외선 열화상법에 의한 콘크리트 공동탐지에 관한 기초연구, 한국콘크리트학회 봄 학술발표회, 한국콘크리트학회 pp. 169-174.
  6. Carslaw, H.S. and Jaeger, J.C. (1959) Early detection by simulated infrared thermography, Advances in Signal Processing for Nondestructive Evaluation of Materials, X.P. Maldague, Ed., Kluwer Academic Publisher, Netherlands, pp. 303-321.
  7. CAMDI-Center for Advanced Monitoring and Damage Inspection (2008) Nondestructive Evaluation of Armor Samples, Army Program Executive Office, University of California, Irvine
  8. Hillemeier, B. (1984) Location of reinforcement by induction-thermography, SPIE Vol520 Thermosense VII, pp. 197-206.
  9. Krapez, J.C., Balegeas, D., Deom, A., and Lepoutre, F. (1994) Early detection by simulated infrared thermography, Advances in Signal Processing for Nondestructive Evaluation of Materials, Kluwer Academic Publishers, Netherlands, pp. 303-321.
  10. Korean Standard (2005) Method of Test for Compressive Strength of Concrete, KSF 2405.
  11. Maekawa, K., Chaube, R., and Kishi, T. (1999) Modeling of Concrete Performance: Hydration, Microstructure Formation and Mass Transport, Routledge, London and New York.
  12. Maldague, X.P.V. (1993) Nondestructive Evaluation of Materials by Infrared Thermography, Springer Verlag, London, pp. 48-53.
  13. Maierhofer, C.H., Arndt, R., Rollig, M., Rieck, C., Walther, A., Scheel, H., and Hillemeier, B. (2006) Application of impulsethermography for non-destructive assessment of concrete structures, Cement and Concrete Composites, Vol. 28, pp. 393-401. https://doi.org/10.1016/j.cemconcomp.2006.02.011
  14. NORDTEST (1999) Chloride Migration Coefficient from Non- Steady-State Migration Experiments, NT BUILD 492.
  15. Shepard, S.M. Hou, J., Ahmed, T., and Lhota, J.R. (2006) Reference- free interpretation of flash thermography data, Insight, Vol. 48, No. 5, pp. 298-301. https://doi.org/10.1784/insi.2006.48.5.298
  16. Shepard, S.M. Hou, J,. Lhota, J.R., and Golden, J.M. (2007a) Automated processing of thermographic derivatives for quality assurance, Optical Engineering, Vol. 46, No. 5, 051008-1-6. https://doi.org/10.1117/1.2741274
  17. Shepard, S.M., Lhota, J.R., and Ahmed, T. (2007b) Flash thermography contrast model based on IR camera noise characteristics, Nondestructive Testing and Evaluation, Vol. 22, Nos. 2-3, pp. 113-126. https://doi.org/10.1080/10589750701448662
  18. Spicer, J.W.M., Osiander, R., Aamodt, L.C., andGivens, R.B. (1998) Microwave thermoreflectometry for detection of rebar corrosion, SPIE, Vol. 3400, 0277-786X, pp. 402-409.
  19. Song, H.-W. and Kwon, S.-J. (2007) Permeability characteristics of carbonated concrete considering capillary pore structure, Vol.37, Issue 6, pp. 909-915. https://doi.org/10.1016/j.cemconres.2007.03.011
  20. Tanaka, H. (2005) Detection of concrete exfoliation by active infrared thermography, Railway Technology Avalanche, No. 10, October, pp. 59.