THE USE OF MINISCREWS FOR TOOTH MOVEMENT IN CHILDREN

성장기 아동에서 miniscrew를 고정원으로 이용한 치아이동

  • Kim, Sang-Min (Department of Pediatric Dentistry, Oral Science Research Center, College of Dentistry, Gangneung-Wonju National University) ;
  • Park, Ho-Won (Department of Pediatric Dentistry, Oral Science Research Center, College of Dentistry, Gangneung-Wonju National University) ;
  • Lee, Ju-Hyun (Department of Pediatric Dentistry, Oral Science Research Center, College of Dentistry, Gangneung-Wonju National University) ;
  • Seo, Hyun-Woo (Department of Pediatric Dentistry, Oral Science Research Center, College of Dentistry, Gangneung-Wonju National University)
  • 김상민 (강릉원주대학교 치과대학 소아치과학교실 및 구강과학연구소) ;
  • 박호원 (강릉원주대학교 치과대학 소아치과학교실 및 구강과학연구소) ;
  • 이주현 (강릉원주대학교 치과대학 소아치과학교실 및 구강과학연구소) ;
  • 서현우 (강릉원주대학교 치과대학 소아치과학교실 및 구강과학연구소)
  • Received : 2010.09.02
  • Accepted : 2010.10.21
  • Published : 2010.11.30

Abstract

Anchorage control in orthodontic treatment is an important factor affecting treatment results. In the conventional approach, intra-oral anchorage such as application of differential force and moment, Nance holding arch and lingual arch, as well as extra-oral anchorage such as head gear were used for anchorage reinforcement. However, these anchorages may result in undesired tooth movement and require patient cooperation. To overcome these disadvantages, skeletal anchorage system was introduced as orthodontic anchorage. Types of skeletal anchorage include implant, onplant, miniplate and miniscrew. Especially, miniscrew has many advantages such as reduced patient cooperation, low cost and easy placement. Recently, it is successfully used in orthodontic treatment. This cases were treated using orthodontic miniscrews for retraction of ectopically erupting maxillary canine and impacted mandibular canine and intrusion of maxillary incisors.

교정치료에 있어서 고정원은 진단 및 치료계획에서부터 치료 종료 단계까지 항상 염두에 두어야 하는 중요한 요소이다. 전통적으로 고정원의 조절을 위하여 차등력, 차등모멘트, 구내 고정원, 구외 고정원 등의 다양한 방법들이 사용되어져 왔다. 그러나 이러한 방법들은 원치 않는 치아의 이동이 발생할 수 있고 환자의 협조도가 필요하다는 한계가 있다. 따라서 환자의 협조도나 주변 치아에 의존하지 않는 골격성 고정원(skeletal anchorage)이 전통적인 방법들의 단점을 극복할 수 있는 대안으로 제시되었다. 골격성 고정원의 종류로는 implant, onplant, miniplate, miniscrew 등이 있다. 이 중에서 miniscrew는 환자의 협조도 감소, 술식의 간편성, 저렴한 비용, 식립부위의 다양성 등의 장점을 가지고 있어 교정치료 시 유용하게 이용될 수 있다. 본 증례는 이소성 맹출 경로를 보이는 상악 견치와 매복된 하악 견치의 견인, 정출된 상악 전치의 압하에 miniscrew를 이용하여 양호한 결과를 보였기에 보고하는 바이다.

Keywords

References

  1. 백승학 외 : 다양한 mini-implant 교정치료 올바른 치료전략과 임상적용. 지성출판사, 서울, 8-73, 2007.
  2. Kinzinger G, Gulden N, Yildizhan F, et al. : Anchorage efficacy of palatally-inserted miniscrews in molar distalization with a periodontally/miniscrew- anchored distal jet. J Orofac Orthop, 69:110-120, 2008. https://doi.org/10.1007/s00056-008-0736-3
  3. Umemori M, Sugawara J, Mitani H, et al. : Skeletal anchorage system for open-bite correction. Am J Orthod Dentofacial Orthop, 115:166-174, 1999. https://doi.org/10.1016/S0889-5406(99)70345-8
  4. 박효상 : Titanium microscrew implant를 이용한 skeletal cortical anchorage. 대한치과교정학회지, 29:699-706, 1999.
  5. 장용걸, 박호원, 이주현 등 : Bone-supported pendulum을 이용한 상악대구치 원심이동. 대한소아치과학회지, 36:464-474, 2009.
  6. Kanomi R : Mini-implant for orthodontic anchorage. J Clin Orthod, 31:763-767, 1997.
  7. Leung MT, Lee TC, Rabie AB, et al. : Use of miniscrews and miniplates in orthodontics. J Oral Maxillofac Surg, 66:1461-1466, 2008. https://doi.org/10.1016/j.joms.2007.12.029
  8. 경승현, 임중기, 박영철 : Miniscrew를 고정원으로 이용한 교정치료. 대한치과교정학회지, 31:415-424, 2001.
  9. 장윤형, 김은영, 김광철 등 : Miniplate를 골격성 고정원으로 이용한 매복된 하악 제1대구치의 교정치료 증례. 대한소아치과학회지, 37:246-251, 2010.
  10. Frank CA : Treatment options for impacted teeth. J Am Dent Assoc, 131:623-632, 2000.
  11. Suri L, Gagari E, Vastardis H : Delayed tooth eruption: pathogenesis, diagnosis, and treatment. A literature review. Am J Orthod Dentofacial Orthop, 126:432-445, 2004. https://doi.org/10.1016/j.ajodo.2003.10.031
  12. Ericson S, Kurol J : Early treatment of palatally erupting maxillary canines by extraction of the primary canines. Eur J Orthod, 10:283-295, 1988.
  13. Ericson S, Kurol J : Resorption of maxillary lateral incisors caused by ectopic eruption of the canines. A clinical and radiographic analysis of predisposing factors. Am J Orthod Dentofacial Orthop, 94:503-513, 1988. https://doi.org/10.1016/0889-5406(88)90008-X
  14. Kojima R, Taguchi Y, Kobayashi H, et al. : External root resorption of the maxillary permanent incisors caused by ectopically erupting canines. J Clin Pediatr Dent, 26:193-197, 2002.
  15. 대한소아치과학회 : 소아.청소년치과학. 신흥인터내셔날, 서울, 134-136, 2007.
  16. 김태우 : 미니 임플란트의 임상 적용. 명문출판사, 서울, 29-68, 2008.
  17. 임수민, 양연미, 김재곤 등 : 혼합치열기의 miniscrew를 이용한 교정치료. 대한소아치과학회지, 35:367-375. 2008.
  18. Miyawaki S, Koyama I, Inoue M, et al. : Factors associated with the stability of titanium screws placed in the posterior region for orthodontic anchorage. Am J Orthod Dentofacial Orthop, 124:373-378, 2003. https://doi.org/10.1016/S0889-5406(03)00565-1
  19. Kang S, Lee SJ, Ahn SJ, et al. : Bone thickness of the palate for orthodontic mini-implant anchorage in adults. Am J Orthod Dentofacial Orthop, 131:S74- S81, 2007. https://doi.org/10.1016/j.ajodo.2005.09.029
  20. Baumgaertel S : Quantitative investigation of palatal bone depth and cortical bone thickness for mini-implant placement in adults. Am J Orthod Dentofacial Orthop, 136:104-108, 2009. https://doi.org/10.1016/j.ajodo.2008.11.020
  21. 경승현 : 미니스크류 식립 부위로서 정중 구개봉합부 골의 두께에 관한 연구. 대한치과교정학회지, 34:63-70, 2004.
  22. Asscherickx K, Vannet BV, Bottenberg P, et al. : Clinical observations and success rates of palatal implants. Am J Orthod Dentofacial Orthop, 137:114-122, 2010. https://doi.org/10.1016/j.ajodo.2008.02.022
  23. Ohashi E, Pecho OE, Moron M, et al. : Implant vs screw loading protocols in orthodontics. Angle Orthod, 76:721-727, 2006.
  24. Huja SS, Litsky AS, Beck FM, et al. : Pull-out strength of monocortical screws placed in the maxillae and mandibles of dogs. Am J Orthod Dentofacial Orthop, 127:307-313, 2005. https://doi.org/10.1016/j.ajodo.2003.12.023
  25. Woods PW, Buschang PH, Owens SE, et al. : The effect of force, timing, and location on bone-toimplant contact of miniscrew implants. Eur J Orthod, 31:232-240, 2009. https://doi.org/10.1093/ejo/cjn091