References
- A-M. Frelin, J-M. Fontbonne, G. Ban, J. Colin, and M. Labalme, “Spectral discrimination of Cerenkov radiation in scintillating dosimeters”, Med. Phys., vol. 32, pp. 3000-3006, 2005. https://doi.org/10.1118/1.2008487
- T. O. White, “Scintillating fibers”, Nucl. Instrum. Phys. Res. A., vol. 273, pp. 820-825, 1988. https://doi.org/10.1016/0168-9002(88)90102-7
- A. S. Beddar, “Plastic scintillation dosimetry and its application to radiotherapy”, Radi. Meas., vol. 41, pp. S124-S133, 2007.
- A. S. Beddar, T. J. Kinsella, A. Ikhlef, and C. H. Sibata, “A miniature 'Scintillator-Fiberoptic-PMT' detector system for the dosimetry of small fields in stereotactic radiosurgery”, IEEE Trans. Nucl. Sci., vol. 48, pp. 924-928, 2001. https://doi.org/10.1109/23.940133
- S. H. Shin, K. W. Jang, D. H. Cho, W. J. Yoo, J. K. Seo, B. Lee, J. H. Moon, S. Kim, and B. G. Park, “Measurements of relative depth dose rates for a brachytherapy Ir-192 source using an organic scintillator fiber-optic radiation sensor”, J. Kor. Sensors. Soc., vol. 17, pp. 462-469, 2008. https://doi.org/10.5369/JSST.2008.17.6.462
- D. H. Cho, K. W. Jang, W. J. Yoo, B. Lee, H. S. Cho and S. Kim, “Fabrication and performance evaluation of one-dimensional fiber-optic radiation sensor for X-ray profile irradiated by clinical linear accelerator”, J. Kor. Sensors. Soc., vol. 16, no. 1, pp. 33-38, 2007. https://doi.org/10.5369/JSST.2007.16.1.033
- L. Archambault, A. S. Beddar, L. Gingras, F. Lacroix, R. Roy, and L. Beaulieu, “Water-equivalent dosimeter array for small-field external beam radiotherapy”, Med. Phys., vol. 34, pp.1583-1592, 2007. https://doi.org/10.1118/1.2719363
- B. Lee, D. H. Cho, K. W. Jang, S. C. Chung, J. W. Lee, S. Kim, and H. Cho, “Measurements and characterizations of Cerenkov light in fiber-optic radiation sensor irradiated by high energy electron beam”, Jpn. J. App. Phys., vol. 45, pp. 7980-7982, 2006. https://doi.org/10.1143/JJAP.45.7980
- F. M. Khan, The Physics of Radiation Therapy - 2nd ed., Baltimore, Williams & Wilkins, pp. 182-185, 1994.
- W. R. Hendee, G. S. Ibbott, and E. G. Hendee, Radiation Therapy Physics - 3rd ed., New Jersey, Jhon Wiley & Sons, p.135, 2005.
Cited by
- Liquid Refractive Index Sensor Based on Cladded Plastic Optical Fiber Taper vol.21, pp.2, 2012, https://doi.org/10.5369/JSST.2012.21.2.151
- Fabrication and Performance Evaluation of a Scintillating Film-based Gamma Imaging Detector to Measure Gamma-ray Distribution vol.24, pp.3, 2015, https://doi.org/10.5369/JSST.2015.24.3.202
- Measurement of Relative Depth dose of Therapeutic Photon Beam Using One-Dimensional Fiber-Optic Phantom Dosimeter vol.20, pp.2, 2011, https://doi.org/10.5369/JSST.2011.20.2.96