Research for Signal Analysis of 18Mn-5Cr Steel Generator Retaining Ring using Ultrasonic Wave

초음파를 이용한 18Mn-5Cr강 발전기 리테이닝 링의 신호분석에 관한 연구

  • 길두송 (전력연구원 원자력발전연구소) ;
  • 안연식 (전력연구원 원자력발전연구소) ;
  • 박상기 (전력연구원 원자력발전연구소)
  • Received : 2009.12.29
  • Accepted : 2010.03.30
  • Published : 2010.04.30

Abstract

Retaining rings are used to support the field winding end turns from the centrifugal force by the high speed of the field and these are the overstressed parts among the generator parts. There have been several retaining failures in Europe and America, all attributable to stress corrosion cracking in 18Mn-5Cr steel. Since then, each manufacture companies have developed a good 18Mn-5Cr steel in temperature, strength characteristic and it is used in many field now. From many findings and test results, we could conformed that the failure might be grown in the overstressed condition unrelated to the moisture particle.

Keywords

References

  1. Ronald J. Zawoysky, "GE Generator Rotor Retaining Rings; Experience and Fleet Data" GE Power Systems, pp. 1-4.
  2. 안연식 외 5인, 2008, "7FA형 가스터빈 주요부품 비파괴 진단기술 개발", 최종보고서, 산업자원부, pp. 418-420.
  3. 임상규, 박상기, 길두송, 2007, "발전기설비초음파 검사 결과", 전력연구원, pp. 13-19.
  4. 조용상, 정계조, 이인철, 2001, "다중센서방식 초음파를 이용한 TBN Blade 루트부/리테이 닝 링검사 및 베어링 C-scan 검사보고서" 전력연구원, pp. 20-23.
  5. L. S. Dorfman, P. C. Riccardella, D. A. Rosario, T. P. Sherlock, 1996, "Retaining Ring Failure at Comanche Unit 2", Final Report, EPRI, pp. 1-3.
  6. 황석환, 최재승, 2000, "2극 발전기의 리테이닝 링열 박음 해석", 대한기계학회 춘추학술대회, pp. 849-853.
  7. 이동민, 2006, "발전기 리테이닝링/슬롯단부의 해석 및 수명평가기술", 한전기공주식회사 기술연구원, pp. 11-30.