DOI QR코드

DOI QR Code

The Indoor Thermal and Air Environment during Winter in One-room Type Multi-family Houses Occupied by University Students

대학생 거주 원룸형 다가구주택의 겨울철 실내열공기환경 실태

  • Choi, Yoon-Jung (Dept. of Housing&Interior Design, Chungbuk National University) ;
  • Kim, Wn-Hak (Dept. of Housing&Interior Design, Chungbuk National University)
  • 최윤정 (충북대학교 생활과학대학 주거환경학과) ;
  • 김운학 (충북대학교 생활과학대학 주거환경학과)
  • Received : 2010.06.04
  • Accepted : 2010.08.04
  • Published : 2010.08.31

Abstract

The purposes of this study were to investigate the state of indoor thermal and air environment during winter in the one-room type multi-family houses occupied by university students and to analyze factors which influenced this environment. Field survey was conducted in 10 houses between 30th January, 2009 and 13th February, 2009 which measured indoor thermal and air elements as well kept records of interviews with residents and other related factors. Measured elements were air temperature, relative humidity, as well as concentrations of $CO_2$, CO, TVOC, and PM-10. The results can be summarized as follows. 1) The mean air temperature in each house ranged from 19.3 to $25.3^{\circ}C$, so most houses were not suitable for evaluation criteria($20-22^{\circ}C$). The average $CO_2$ concentration in each house was 965~3259ppm, so most houses exceeded evaluation criteria(1000ppm). The average TVOC concentration in each house were 0.00~1.17ppm, 5 houses exceeded evaluation criteria(0.12ppm). 2) Relative humidity, CO concentration, and PM-10 concentration were suitable for evaluation criteria. Therefore, indoor thermal and air environment during winter in one-room type multi-family housing occupied by university students was found to be generally uncomfortable. Important factor which were found to influence air temperature and the concentration of $CO_2$ were smaller space capacity than general house. Other factors which were found to influence the environment of these houses were the existence of a balcony as well as factors relating to the behavior of occupants such whether or not heating were operated, whether windows were opened, whether fans used, whether occupants smoked or used cosmetics, and whether the space was dusted.

Keywords

References

  1. 건축물의 설비기준 등에 관한 규칙 . (2009). 제21조.
  2. 건축물의 에너지절약설계기준 . (2008). 별표7.
  3. 건축물의 피난방화구조등의 기준에 관한 규칙 . (2010). 제17조.
  4. 건축법 시행령. (2010). 제3조의4.
  5. 김명룡. (2003). 학생주거용 다가구주택의 실태분석과 개선방안에 대한 연구. 전북대학교 대학원 석사학위논문.
  6. 다중이용시설등의 실내공기질관리법 시행규칙 . (2008). 제3조.
  7. 대학가 알짜 원룸 찾아라. (2008, 1. 9). 주간한국 매거진. 자료검색일 2009, 1. 17, 자료출처 http://weekly.hankooki.com/lpage/nation/200801/wk2008010914035537070.htm
  8. 박진철, 이언구. (1999). 다세대주택의 실내공기환경 개선에 관한 연구 : 반지하세대를 중심으로. 대한건축설비학회, 2(2), 101-111.
  9. 시행령 . (2010). 제3조.
  10. 심현숙, 최윤정. (2008). 리모델링후 거주중인 아파트 단위 주거의 실내공기질 평가. 대한건축학회논문집, 24(12), 303-312.
  11. 원룸과 사회변화. (2002, 2. 21). 네이버. 자료검색일 2009, 1. 15, 자료출처 http://news.naver.com/ main/read.nhn?mode=LSD&mid=sec&sid1=110&oid= 038&aid=0000125167
  12. 이민정. (2003). 서울시 주택내 Formaldehyde와 VOCs의 오염농도에 관한 연구. 연세대학교 석사학위논문.
  13. 이승민. (2000). 건축물의 실내공기환경 특성 및 평가. 한양대학교 박사학위논문.
  14. 이승민, 손장열, 강순주, 강대식, 김성신. (1996). 겨울철 아파트의 실내공기환경 평가에 관한 연구. 대한건축학회학술발표대회논문집, 16(2), 277-279.
  15. 주택법 . (2010). 제2조 제4호.
  16. 최윤정. (2002). 원룸형 다가구주택의 봄철 실내온열환경 평가, 충북대학교 생활과학연구논총 제5호, 33-44.
  17. 최윤정, 정연홍. (2008). 아파트의 겨울철 실내온열환경 실태와 생활요인 분석. 한국주거학회논문집 , 19(4), 97-105.

Cited by

  1. An analysis of the Influencing Factors and Actual State of Indoor Air Quality in Semi-underground Multi-family Housing Units vol.20, pp.5, 2011, https://doi.org/10.5934/KJHE.2011.20.5.1075