Abstract

The objective of this study is to examine the structural performance on the Rectangular Steel Tube Column-to-H Beam connections using one-side bolts and T-stub. Although a rectangular steel tube comparing with a H-shaped steel has many advantages and is more efficient, its application is limited due to the lack of experiences and connection details. Existing steel moment connections using the rectangular steel tube are mainly using through plate diaphragms. Its processing of construction is so complicated that it is hard to apply in the field. In this study, the structural performance and the earthquake capacity for T-stub connection with one-side bolts were investigated. And it is performed a comparative analysis of strength, rigidity, total rotation and energy absorption capacity for the various connection details.

각형강관 기둥은 H형강에 비해서 구조효율성이 높고, 많은 장점이 있음에도 불구하고, 접합 디테일의 부족 및 경험 부족 등의 이유로 현장에서 적용이 제한적이다. 각형강관 기둥을 사용한 기존의 모멘트 접합부는 관통형 다이아프램, 내/외측 다이어프램 형식 등이 있으며 일반적으로 관통형 다이어프램을 사용하고 있다. 이는 시공과정이 복잡하여 현장에서의 적용을 어렵게 한다. 그러므로 이 연구에서는 원사이드 볼트를 적용하여 각형강관 기둥의 절단 및 용접을 하지 않는 접합상세에 대한 구조성능 및 내진성능을 평가하고자 하였다.

Keywords

References

  1. 대한건축학회(2009) 건축구조 설계기준.
  2. 김종성(2009) 반강접 접합부를 갖는 강골조의 거동에 관한 해석적 연구. 한국강구조학회논문집, 한국강구조학회, 제21권, 제5호, pp.483-492.
  3. 김태진, 김은석, 김진구(2007) 중저층 철골건물 보-기둥 접합부의 내진 및 붕괴저항 성능평가, 대한건축학회논문집, 대한건축학회, 제23권, 제10호, pp.59-66.
  4. 이명재(2006) T-stub를 이용한 접합부의 초기강성 평가, 한국강구조학회 논문집, 제18권, 제6호, pp.805-814
  5. 정진안, 최성모(2004) 연직 스티프너 보강형 각형강관 기둥-보 접합부의 구조적 거동, 대한건축학회논문집, 대한건축학회, 제20권, 제4호, pp.59-66.
  6. 조재철, 김원기, 이명재(1999) 반강접 접합부의 요소인 개량 T-stub 의 비탄성 해석과 약산식. 한국강구조학회논문집, 한국강구조학회, 제11권, 제3호, pp.271-281.
  7. AISC (2006) Seismic Design Manual, American Institute of Steel Construction.
  8. BSI (1993) Eorocode No3. Design of steel structures, British Standards Institution.
  9. FEMA (2000) Recommended Seismic Design Criteria for New Steel Moment-Frame Buildings(FEMA-350), Federal Emergency Management Agency.
  10. Harada, Y., Arakaki, T., and Morita, K. (2002) Structural Behavior of RHS Column-to-H Beam Connection with High Strength Bolts. International Journal of Steel Structures, Vol. 2, No. 2, pp.111-121.
  11. Nakashima, M., Inoue, K., and Tada, M. (1998) Classification of damage to steel buildings observed in the 1995 Hyogoken-Nanbu earthquake, Engineering Structures, Vol. 20, pp.271-281. https://doi.org/10.1016/S0141-0296(97)00019-9
  12. Nishimura, K., Fujita, Y., Fukumoto, Y., Masuo, K., and Mukaide, S. (2005) Experimental study on RHS column to vertical haunch-beam connections using external diaphragm with high strength bolts Journal of Structural and Construction Engineering, (Transactions of AIJ). No. 591, pp.137-144.
  13. Shin, K.J., Kim, Y.J., and Oh, Y.S. (2008) Seismic behaviour of composite concrete-filled tube column-to-beam moment connections, Journal of Constructional Steel Research, No. 64, pp.118-127.
  14. Wilkinson, S., Hurdman, G., and Crowther, A. (2006) A moment resisting connection for earthquake resistant structures, Journal of Constructional Steel Research, No. 62, pp.295-302.