The Analysis of Runoff Characteristics by Alterations of SCS-CN Value using LID Method

LID 기법 적용에 의한 SCS-CN값 변화가 강우유출특성에 미치는 영향 분석

  • Kwon, Jun-Hee (Department of Environmental & Urban Engineering, Chungbuk National University) ;
  • Park, In-Hyeok (Department of Environmental & Urban Engineering, Chungbuk National University) ;
  • Ha, Sung-Ryoung (Department of Environmental & Urban Engineering, Chungbuk National University)
  • Received : 2009.10.07
  • Accepted : 2009.12.21
  • Published : 2010.02.28

Abstract

The objective of the research is to analyze changing trend of water discharge in precipitation, according to changing land use, through an environment-friendly urban development method called LID. The study chose S1 basin (Separated Sewer districts) in Cheongju region for survey. Among LID methods, relatively more applicable methods of green rooftop space and parking lot with permeable material were selected to construct plausible scenarios. Curve Number (CN) value was calculated due to land use patterns in each scenario, and SWMM model simulation were conducted during 2008 for comparative analysis. For Case 1, only parking lot with permeable material was applied to the scenario. Green rooftop space I and II were applied to Case 2 and 3 respectively. For Case 4 and 5, green rooftop space I and II were applied, in addition to parking lot with permeable material, Calculation of CN value showed that for S1 basin, the value was 88.1 (prior to scenario application), 86.5 (Case 1), 81.9 (Case 2), 68.5 (Case 3), 80.4 (Case 4) and 67.2 (Case 5). Changing pattern of rain water discharge was analyzed for each scenario. For Case 1, the change was not remarkable before and after application of scenario. In Case 2 and 4, the impact of rain water discharge as source of pollutant fell to 20~30%. The rate dropped to 30~50% in Case 3 and 5 respectively. The result demonstrates that the amount of rain water discharge, amount and frequency of sewer overflow, frequency of rain water discharge, and pollution load decreased in accordance with declining CN value in each scenario. In installing green rooftop space, the effect was twice greater when rain water discharge was directly infiltrated into soil.

Keywords

References

  1. 선우중호, 2006, 수문학, 동명사.
  2. 환경부, 2006, 물환경관리기본계획.
  3. 박준호외 7인, 2008, SWMM을 이용한 춘천 거두 1지구 LID 개념 적용으로 인한 유출 감소 특성 분석, 한국물환경학회, 24(6).
  4. 이동근 외 3인, 2006, 옥상녹화의 우수유출량 저감효과에 관한 연구, 한국환경복원녹화기술학회지
  5. 주진호 외 6인, 2007, 낙동강 수계 고랭지 밭의 비점오염 물질 유출 특성 조사 및 단위 유출량산정, 한국환경농학회지, 26(3).
  6. 전지홍 외 2인, 2009, 지속가능한 도시개발을 위한 LED평가모델(LIDMOD)개발과 수질오염총량제에 대한 적용성 평가, 한국물환경학회, 25(1).
  7. 김이형, 2008, 21세기 친환경 건설을 위한 Low Impact Development(LID) 기술, 물과 미래, 41(6).