DOI QR코드

DOI QR Code

Real Time Drowsiness Detection by a WSN based Wearable ECG Measurement System

  • Received : 2011.08.02
  • Accepted : 2011.10.23
  • Published : 2011.11.30

Abstract

Whether a person is feeling sleepy or reasonably awake is important safety information in many areas, such as humans operating in traffic or in heavy industry. The changes of body signals have been mostly researched by looking at electroencephalogram(EEG) signals but more and more other medical signals are being examined. In our study, an electrocardiogram(ECG) signal is measured at a sampling rate of 100 Hz and used to try to distinguish the possible differences in signal between the two states: awake and drowsy. Practical tests are conducted using a wireless sensor node connected to a wearable ECG sensor, and an ECG signal is transmitted wirelessly to a base station connected to a server PC. Through the QRS complex in the ECG analysis it is possible to obtain much information that is helpful for diagnosing different types of cardiovascular disease. A program is made with MATLAB for digital signal filtering and graphing as well as recognizing the parts of the QRS complex within the signal. Drowsiness detection is performed by evaluating the R peaks, R-R interval, interval between R and S peaks and the duration of the QRS complex..

Keywords

References

  1. X. Yu, "Real-time nonintrusive detection of driver drowsiness", Final Technical Report, Intelligent Transportation Systems Institute, University of Minnesota, May 2009.
  2. J. Dorrian, S. D. Baulk, and D. Dawson, "Work hours, workload, sleep and fatigue in australian rail industry employees", Appl Ergon., vol. 42, no. 2, pp. 202-209, 2011. https://doi.org/10.1016/j.apergo.2010.06.009
  3. C. Zywietz, "A brief history of electrocardiography - progress through technology", Distribution, pp. 10- 19, 1888.
  4. W. Y. Chung, Y. D. Lee, and S. J. Jung, "A wireless sensor network compatible wearable u-healthcare monitoring system using integrated ECG, accelerometer and $SpO_{2}$", Proc. of International Conf. of the IEEE Engineering in Medicine and Biology Society, pp. 1529-1532, 2008.
  5. H. Ueno, M. Kaneda, and M. Tsukina, "Development of drowsiness detection system", Proc. of Vehicle Navigation & Information Systems Conf., pp. 15-20, 1994.
  6. T. Yamakoshi, P. Rolfe, Y. Yamakoshi, and H. Hirose, "A novel physiological index for $driver^{\circ}\Phi s $ activation state derived from simulated monotonous driving studies", Transp. Res. Part C: Emerging Technologies, vol. 17, no. 1, pp. 69-80, 2009. https://doi.org/10.1016/j.trc.2008.09.002
  7. G. Z. Yang, Body Sensor Networks, Springer-Verlag London, 2006.
  8. S. J. Jung, T. H. Kwon, and W. Y. Chung, "A new approach to design ambient sensor network for real time healthcare monitoring system", Proc. of IEEE Sensors 2009 Conf., pp. 576-580, October 26, New Zealand, 2009.
  9. J. Pan and W. J. Tompkins, "A real-time QRS detection algorithm", IEEE Trans. Biomed. Eng., vol. 32, no. 3, pp. 230-236, 1985. https://doi.org/10.1109/TBME.1985.325532
  10. P. S. Hamilton and W. J. Tompkins, "Quantitative investigation of QRS detection rules using the MIT/BIH arrhythmia database", IEEE Trans. Biomed. Eng., vol. 33, no. 12, pp. 1157-1165, 1986. https://doi.org/10.1109/TBME.1986.325695
  11. A. S. Ramiro, Textbook of Advanced Cardiac Life Support, American Heart Association, 1987.
  12. G. Clifford, http://www.robots.ox.ac.uk/
  13. J. P. Degaute, P. v. de Bornc, P. Linkowski, and E. V. Caute, "Quantitative analysis of the 24-hour blood pressure and heart rate patterns in young men", Hypertension, vol. 18, no. 2, pp. 199-210, 1991. https://doi.org/10.1161/01.HYP.18.2.199

Cited by

  1. Mobile Healthcare System Based on Bluetooth Medical Device vol.21, pp.4, 2012, https://doi.org/10.5369/JSST.2012.21.4.241