DOI QR코드

DOI QR Code

Fabrication and Characterization of a Wrist Wearable Cuffless Pulsimeter by Using the Hall Effect Device

  • Lee, Sang-Suk (Department of Oriental Biomedical Engineering, Sangji University) ;
  • Choi, Jong-Gu (Eastern-western Biomedical Engineering, Sangji University) ;
  • Son, Il-Ho (Department of Oriental Biomedical Engineering, Sangji University) ;
  • Kim, Keun-Ho (Department of Oriental Biomedical Engineering, Sangji University) ;
  • Nam, Dong-Hyun (Department of Oriental Medicine, Sangji University) ;
  • Hong, You-Sik (Department of Computer Science, Sangji University) ;
  • Lee, Woo-Beom (Department of Computer Science, Sangji University) ;
  • Hwang, Do-Guwn (Department of Oriental Biomedical Engineering, Sangji University) ;
  • Rhee, Jang-Roh (Department of Physics, Sookmyung Women's University)
  • Received : 2011.10.06
  • Accepted : 2011.11.01
  • Published : 2011.12.31

Abstract

A wrist wearable cuffless pulsimeter with a portable and small size apparatus using Hall effect is fabricated. The analysis of the pulse wave measured by the testing product of pulsimeter is done to measure the pulse rate and blood pressure. The blood pressure obtained by the puslimeter is compared with the practical values measured by electronic or mercury liquid blood pressure meters. The detail analysis of a pulse wave measured by a wrist wearable cuffless pulsimeter detecting the changes of the magnetic field can be used to develop a new diagnostic algorithm of blood pressure applying for oriental medical apparatus.

Keywords

References

  1. Q. Yu, J. Zhou, and Y. C. Fung, Am. J. Physiol. Heart Circ. Physiol. 265, 52 (1993).
  2. E. M. Ka and D. R. Son, J. Magnetics 13, 34 (2008). https://doi.org/10.4283/JMAG.2008.13.1.034
  3. S. W. Kim, Y. G. Choi, H. S. Lee, D. H. Park, D. G. Hwang, S. S. Lee, G. W. Kim, S. G. Lee, and S. J. Lee, J. Appl. Phys. 99, R908 (2006).
  4. S. D. Choi, S. W. Kim, G. W. Kim, M. C. Ahn, M. S. Kim, D. G. Hwang, and S. S. Lee, J. Magn. Magn. Mater. 310, e983 (2007). https://doi.org/10.1016/j.jmmm.2006.10.1027
  5. S. S. Lee, D. G. Hwang, G. W. Kim, S. W. Kim, and H. H. Kim, The Korea Patent Registration Number; 0730385 (2007).
  6. S. D. Choi, M. S. Kim, M. C. Ahn, Y. G. Choi, G. W. Kim, D. H. Park, D. G. Hwang, and S. S. Lee, J. Korean Magn. Soc. 16, 216 (2006). https://doi.org/10.4283/JKMS.2006.16.4.216
  7. M. F. P. Rourke, R. P. Kelly, and A. P. Avolio, The Arteral Pulse, 1st Ed., Lea & Febiger, Philadelphia (1992).
  8. S. S. Lee, G. W. Kim, M. C. Ahn, Y. S. Park, J. G. Choi, S. D. Choi, D. H. Park, D. G. Hwang, and H. R. Yoon, J. Biomed. Eng. Res. 28, 721 (2007).
  9. S. S. Lee, M. C. Ahn, and S. H. Ahn, J. Magnetics 14, 132 (2009). https://doi.org/10.4283/JMAG.2009.14.3.132
  10. S. M. Sze, Physics of Semiconductor Devices, 2nd Ed., John Wiley & Sons, Hoboken (1981) pp. 30-35.
  11. M. C. P. Carrasquero, L. M. H. Bemard, H. Kobori, Y. Ozawa, K. S. H. Smith, L. L. Hamm, and L. G. Navar, Hypertension 44, 223 (2004). https://doi.org/10.1161/01.HYP.0000135678.20725.54

Cited by

  1. Pulse Wave Velocity Measured by Radial Artery Clip-type Pulsimeter Equipped with a Hall Device and Electrocardiogram vol.23, pp.4, 2013, https://doi.org/10.4283/JKMS.2013.23.4.130
  2. Development of Oriental-Western Fusion Patient Monitor by Using the Clip-type Pulsimeter Equipped with a Hall Sensor, the Electrocardiograph, and the Photoplethysmograph vol.23, pp.4, 2013, https://doi.org/10.4283/JKMS.2013.23.4.135
  3. Fuzzy Simulation of a Multi-electronic Acupuncture System and Clip-type Pulsimeter Equipped with a Magnetic Sensing Hall Device vol.19, pp.3, 2014, https://doi.org/10.4283/JMAG.2014.19.3.255
  4. Analysis of Magnetic Field Variation for Pulse Wave by Using Finite Element Method vol.24, pp.3, 2014, https://doi.org/10.4283/JKMS.2014.24.3.090
  5. Property of Wireless Clip-type Pulsimeter by Using a Hall Device and a Permanent Magnet vol.24, pp.6, 2014, https://doi.org/10.4283/JKMS.2014.24.6.179
  6. Measurement of Spatial Pulse Wave Velocity by Using a Clip-Type Pulsimeter Equipped with a Hall Sensor and Photoplethysmography vol.13, pp.4, 2013, https://doi.org/10.3390/s130404714