DOI QR코드

DOI QR Code

Study on the Buckling Behaviour of Cold-Formed Angles in Transmission Towers

  • Yang, Fengli (Engineering Mechanics Department, China Electric Power Research Institute) ;
  • Han, Junke (Engineering Mechanics Department, China Electric Power Research Institute) ;
  • Yang, Jingbo (Engineering Mechanics Department, China Electric Power Research Institute) ;
  • Li, Zhenbao (College of Architecture and Civil engineering, Beijing University of Technology)
  • Published : 2011.12.31

Abstract

Considering the structural characteristics of transmission towers, four sections of cold-formed angles with different slenderness ratios and constrained types were selected for the experimental and numerical study. Experiments and finite element analysis for the ultimate loads of the compression cold-formed angles were carried out. The finite element model well predicts the buckling behaviour of the cold-formed members. For the axial compression members, the load-strain curves as well as the ultimate loads were analyzed, and the experimental ultimate loads were compared with those of calculated by the applicable standards. It shows that the applicable standards aren't adaptive to the strength design of the compression cold-formed members in transmission towers. Through the analysis of the experimental and FEA results, the fitting curve of the stability coefficients for the cold-formed members in transmission towers was determined. The ultimate loads calculated by the fitting curve are well agreed with the experimental values, especially for the members with relatively low slenderness ratios. Some modification suggestions were proposed for the calculation of the ultimate load for the axial compression cold-formed angle. Experimental analysis on the cold-formed members of the other five constrained types was completed, and the modification formulas of the slenderness ratios for members of different constrained types were obtained.

Keywords

References

  1. ASCE (1998). Design of Latticed Steel Transmission Structures. American Society of Civil Engineers, New York, USA.
  2. CENELEC (2001). Overhead electrical lines exceeding AC 45kV. European Committee for Electrotechnical Standardization, Brussels, Belgium.
  3. He, C. H. (2004). "Feasibility discussion on application of high strength cold-formed section steel in transmission tower." Steel Construction, 19(74), pp. 35-37.
  4. Mohan, S. J., Shabeen, S. R., and Samuel, K. G. M. (2006). "Behavior of cold formed lipped angles in transmission line towers." Thin-Walled Structures, 44, pp. 1017-1030. https://doi.org/10.1016/j.tws.2006.07.006
  5. NBC (2003). Technical code of cold-formed thin-wall steel structures. National Building Commission of PRC, China Planning Press, Beijing, China (in Chinese).
  6. NETC (2002). Technical regulation of design for tower and pole structures of overhead transmission line. National Economy and Trade Commission of PRC, China Electric Press, Beijing, China (in Chinese).
  7. Popovic, D., Hancock, G. J., and Rasmussen, K. J. R. (1999). "Axial compression tests of cold-formed angles." Journal of Structural Engineering, 125(5), pp. 515-523. https://doi.org/10.1061/(ASCE)0733-9445(1999)125:5(515)
  8. Young, B. (2005). "Experimental investigation of coldformed steel lipped angle concentrically loaded compression members." Journal of Structural Engineering, 131(9), pp. 1390-1396. https://doi.org/10.1061/(ASCE)0733-9445(2005)131:9(1390)
  9. Young, B. and Ellobody, E. (2005). "Buckling analysis of cold- formed steel lipped angle columns." Journal of Structural Engineering, 131(10), pp. 1570-1579. https://doi.org/10.1061/(ASCE)0733-9445(2005)131:10(1570)
  10. Young, B. and Rasmussen, K. J. R. (1999). "Behavior of cold-formed singly symmetric columns." Thin-Walled Structures, 33, pp. 83-102. https://doi.org/10.1016/S0263-8231(98)00044-5

Cited by

  1. Seismic Performance of Medium Thick-Walled Cold-Formed Steel Top-and-Seat Angle Joint vol.501, pp.None, 2014, https://doi.org/10.4028/www.scientific.net/amm.501-504.1609