DOI QR코드

DOI QR Code

Sinusoidal Current Control of Single-Phase PWM Converters under Voltage Source Distortion Using Composite Observer

왜곡된 전원 전압하에서 Composite 관측기를 이용한단상 PWM 컨버터의 정현파 전류 제어

  • Received : 2011.08.05
  • Accepted : 2011.09.02
  • Published : 2011.10.20

Abstract

In this paper, a high-performance current control for the single-phase PWM converter under distorted source voltages is proposed using a composite observer. By applying the composite observer, the fundamental and high-order harmonic components of the source voltage and current are extracted without a delay. The extracted fundamental component is used for a phase-lock loop (PLL) system to detect the phase angle of the source voltage. A multi-PR (proportional-resonant) controller is employed to regulate the single-phase line current. The high-order harmonic components of the line current are easily eliminated, resulting in the sinusoidal line current. The simulation and experimental results have verified the validity of the proposed method.

본 논문에서는 composite 관측기를 이용하여 전원전압 왜곡시 단상 PWM 컨버터의 고성능 전류제어를 제안한다. composite 관측기를 적용함으로써 전원 전압 및 전류의 기본파와 고조파 성분을 시간지연 없이 추출할 수 있다. 추출된 기본파 성분은 전원단의 페이저 각을 찾는 PLL시스템에 이용된다. 멀티 비례-공진 제어기로 단상 입력전류를 정현파로 제어하고 고조파 성분을 제거한다. 시뮬레이션과 실험 결과로 제안된 방법의 타당성을 검증한다.

Keywords

References

  1. M. F. Schonardie and D. C. Martins, "Solar grid-connected three-phase system with active and reactive power control and input voltage clamped", in Proc. IEEE Elec., Circuits and Systems Conf., pp. 463-466, 2007, Dec.
  2. J. P. Lee, B. D. Min, T. J. Kim, D. W. Yoo, and J. Y. Yoo, "Design and control of novel topology for photovoltaic DC/DC converter with high efficiency under wide load ranges", Journal of Power Electronics, Vol. 9, No. 2, pp. 300-307, 2009, Mar.
  3. B. Singh, B. N. Singh, A. Chandra, K. Al-Haddad, A. Pandey, and D. P. Kothari, "A review of three-phase improved power quality AC-DC converters", IEEE Trans. Ind. Electron., Vol. 51, No. 3, pp. 641-660, 2004, Jun. https://doi.org/10.1109/TIE.2004.825341
  4. S. Peng, A. Luo, Y. Chen, and Z. Lv, "Dual-loop power control for single-phase grid-connected converters with LCL filter", Journal of Power Electronics, Vol. 11, No. 4, pp. 456-463, 2011, Jul. https://doi.org/10.6113/JPE.2011.11.4.456
  5. F. D. Freijedo, J. D. Gandoy, O. Lopez, and E. Acha, "Tuning of phase-lock loops for power converters under distorted utility conditions", IEEE Trans. Ind. Appl., Vol. 45, No. 6, pp. 2039-2047, 2009, Nov./Dec. https://doi.org/10.1109/TIA.2009.2031790
  6. T. Thacker, D. Boroyevich, R. Burgos, and F. Wang, "Phase-lock loop noise reduction via phase detector implementation for single-phase systems", IEEE Trans. Ind. Electron., Vol. 58, No. 6, pp. 2482-2490, 2011, Jun. https://doi.org/10.1109/TIE.2010.2069070
  7. S. Shinnaka, "A robust single-phase PLL system with stable and fast tracking", IEEE Trans. Ind. Appl., Vol. 44, No. 2, pp. 624-633, 2008, Mar./Apr. https://doi.org/10.1109/TIA.2008.916750
  8. X. S. Pu, T. H. Nguyen, D. C. Lee, and S. G. Lee, "Identification of DC-link capacitance for single-phase AC/DC PWM converters", Journal of Power Electronics, Vol. 10, No.3, pp. 270-276, 2010, May. https://doi.org/10.6113/JPE.2010.10.3.270
  9. A. F. Zobaa, "Voltage harmonic reduction for randomly time-varying source characteristics and voltage harmonics", IEEE Trans. Power Del., Vol. 21, No. 2, pp. 816-822, 2006, Apr. https://doi.org/10.1109/TPWRD.2005.864043
  10. T. A. George and D. Bones, "Harmonic power flow determination using the fast Fourier transform", IEEE Trans. Power Del., Vol. 6, No. 2, pp. 530-535, 1991, Apr. https://doi.org/10.1109/61.131107
  11. X.-S. Pu, T. H. Nguyen, D.-C. Lee, and S.-G. Lee, "Capacitance estimation of DC-link capacitors for single-phase PWM converters", in Proc. IEEE Power Electronics and Motion Control Conf., pp. 1656-1661, 2009, May.
  12. H. S. Song, R. Keil, P. Mutschler, V. Weem, and K. Nam, "Advanced control scheme for a single-phase PWM rectifier in traction application", in Proc. IEEE IAS Conf., pp. 1558-1565, 2003, Oct.
  13. R. I. Bojoi, L. R. Limongi, D. Rooiu, and A. Tenconi, "Enhanced power quality control strategy for single-phase inverters in distributed generation systems", IEEE Trans. Power Electron., Vol. 26, No. 3, pp. 798-806, 2011, Mar. https://doi.org/10.1109/TPEL.2010.2103572
  14. C. T. Chen, Linear System Theory and Design. NewYork: Oxford University Press, 1999.
  15. K. Selvajyothi and P. A. Janakiraman, "Extraction of harmonics using composite observers", IEEE Trans. Power Del., Vol. 23, No. 1, pp. 31-40, 2008, Jan. https://doi.org/10.1109/TPWRD.2007.911141
  16. K. Selvajyothi and P. A. Janakiraman, "Reduction of voltage harmonics in single phase inverters using composite observers", IEEE Trans .Power Del., Vol. 5, No. 2, pp. 1045-1057, 2010, Apr.
  17. S. A. Oliveira da Silva, R. Novochadlo, and R.A. Modesto, "Single-phase PLL structure using modified p-q theory for utility connected systems", in Proc. IEEE Power Electron. Spec. Conf., pp. 4706-4711, 2008, Jun.
  18. G.-M. Lee, D.-C. Lee, and J.-K. Seok, "Control of series active power filters compensating for source voltage unbalance and current harmonics", IEEE Trans. on Industrial Electronics, Vol. 51, No. 1, pp. 132-139, 2004, Feb. https://doi.org/10.1109/TIE.2003.822040

Cited by

  1. Advanced SOGI-FLL Scheme Based on Fuzzy Logic for Single-Phase Grid-Connected Converters vol.14, pp.3, 2014, https://doi.org/10.6113/JPE.2014.14.3.598
  2. Control Strategy for Three-Phase Grid-Connected Converters under Unbalanced and Distorted Grid Voltages Using Composite Observers vol.13, pp.3, 2013, https://doi.org/10.6113/JPE.2013.13.3.469