DOI QR코드

DOI QR Code

Realization of Swept Source-Optical Coherence Tomography using FDML Laser

FDML 방식 스위핑 광원을 사용한 SS-OCT 구현

  • Eom, Jin-Seob (Department of Electronics Engineering, The School of Information Technology, Kangwon National University)
  • 엄진섭 (강원대학교 IT대학 전자공학과)
  • Received : 2010.11.15
  • Accepted : 2011.01.07
  • Published : 2011.01.31

Abstract

In this paper, the swept source-optical coherence tomography system using frequency domain mode locked(FDML) laser has realized. The FDML swept source laser showed 55.03 kHz sweeping speed, 125 nm sweeping range, and 9 mW output optical power, which are the superiority of FDML laser compared to previous swept source lasers. Also, through the cross-sectional image captured at 5 frames per second for a mirror, a 1 mm-thickness glass plate, and a thumb bottom, the performance of the system has demonstrated.

Keywords

References

  1. David Huang and James G. Fujimoto, “Optical coherence tomography”, Science, vol. 254, pp. 1178-1181, 1991. https://doi.org/10.1126/science.1957169
  2. R. Leitgeb, C. K. Hitzenberger, and A. F. Fercher, “Performance of fourier domain vs. time domain optical coherence tomography”, Opt. Express, vol. 11, pp. 889-894, 2003. https://doi.org/10.1364/OE.11.000889
  3. M. A. Choma, M. V. Sarunic, C. Yang, and J. Izatt, “Sensitivity advantage of swept source and fourier domain optical coherence tomography”, Opt. Express, vol. 11, pp. 2183-2189, 2003. https://doi.org/10.1364/OE.11.002183
  4. R. Huber, M. Wojtkowski, K. Taira, J. G. Fujimoto, and K. Hsu, “Amplified, frequency swept lasers for frequency domain reflectometry and OCT imaging : design and scaling principles,” Opt. Express, vol. 13, pp. 3513-3528, 2005. https://doi.org/10.1364/OPEX.13.003513
  5. A. G. Podoleanu, “Unbalanced versus balanced operation in an optical coherence tomography system,” Appl. Opt. vol. 39, pp. 173-182, 2000. https://doi.org/10.1364/AO.39.000173
  6. Eugene Hecht, Optics, Addison-Wesley, 1987.
  7. H. S. Kim, M. Y. Namgoong, J. R. Lee, and J. S. Eom, “Real of swept source optical coherence tomography system using loop mirror within reference arm”, Conference on Optoelectronics & Optical Communications(COOC) 2007, vol. 14, pp. 402-403, 2007.
  8. Wook Jae Yoo, Ji Yeon Heo, Dong Hyun Cho, Kyoung Won Jang, Jeong Ki Seo, Bongsoo Lee, Young-Ho Cho, Joo Hyun Moon, and Byung Gi Park, “Spectroscopic study on the development of fiber-optic pH sensor”, J. Kor. Sensors. Soc., vol. 18, no. 5, pp. 365-371, 2009. https://doi.org/10.5369/JSST.2009.18.5.365

Cited by

  1. A Study on SOA Dimming Driver with Current Pattern Design Capability vol.27, pp.2, 2013, https://doi.org/10.5207/JIEIE.2013.27.2.022
  2. Low Cost Signal Generator with Frequency High-Resolution for SS-OCT vol.22, pp.1, 2013, https://doi.org/10.5369/JSST.2013.22.1.84
  3. A Study on SOA Driver with Capability to Control Current and Temperature Transient Response vol.28, pp.2, 2014, https://doi.org/10.5207/JIEIE.2014.28.2.001