Comparative Studies on the Concordance Rate of Pulse Condition Interpretation between Interpreters and Pulse Analyser

맥진기 결과에 대한 판독자간의 판독 일치율 비교 연구

  • Kang, Sei-Young (Dept. of Internal Medicine, College of Korean Medicine, Woo-Suk University) ;
  • Jang, In-Soo (Dept. of Internal Medicine, College of Korean Medicine, Woo-Suk University) ;
  • Kim, Lak-Hyung (Dept. of Neuropsychiatry, College of Korean Medicine, Woo-Suk University)
  • 강세영 (우석대학교 한의과대학 한방내과학 교실) ;
  • 장인수 (우석대학교 한의과대학 한방내과학 교실) ;
  • 김락형 (우석대학교 한의과대학 한방신경정신과 교실)
  • Received : 2011.11.14
  • Accepted : 2011.12.14
  • Published : 2011.12.27

Abstract

Objectives : The purpose of our investigation is to determine degrees of concordance rate among interpreters. Furthermore, we have examined how much concordance rate to come out when beginners have been compared with the pulse analyzer. Methods : Thirty-nine volunteers were enrolled for this study. These subjects took a 5-minute rest in a sitting position as instructed by the protocol. As they were not allowed to move or speak, radial artery pulse conditions were measured on the lower arm of each subject by means of the pulse analyzer under investigation. Two Korean medical doctors, who did not know the status of default pulse conditions, were also instructed to intuitively choose the most corresponding one in comparison with 13 default pulse conditions. Subsequently, we investigated results between interpreters as well as results between interpreter and pulse analyzer. Results : The total concordance rate, with similar concordance rates being included, between interpreters, between interpreter A and pulse analyzer, and between interpreter B and pulse analyzer was 56.4%, 79.5%, and 71.8% respectively. In faint fine weak pulse(微細弱脈) case, interpreter A and B selected 6 and 7 cases respectively, matched the concordance rate 5, and corresponded separately with the pulse analyzer interpreting 8 cases. Conclusions : In case of skipping pulse 2(促2脈), short pulse(短脈), faint fine weak pulse(微細弱脈), the concordance between interpreters also matches with results drawn from the pulse analyzer. The concordance rate goes higher in proportion with such smaller pulse conditions as faint fine weak pulse(微細弱脈) and short pulse(短脈).

Keywords

References

  1. 하인영, 윤여충, 윤대환, 최찬헌, 이영수, 임승일 외. 맥의 빠르기, 크기, 깊이에 관한 전통맥진과 기기측정 맥진의 비교 연구. 경락경혈학회지. 2011 ; 28(1) : 23-37.
  2. Kang HJ, Lee YH, Kim KC, Han CH. A comparative study of methods on measurement of peripheral pulse wave form. The Journal of Korean Oriental Medicine. 2009 ; 30(3) : 98-105.
  3. 이전, 우영재, 전영주, 이유정, 유현희, 김종열. 한의사 맥진 가압력 재현에 대한 고찰. 한국한의학연구원논문집. 2008 ; 14(3) : 113-9.
  4. 강희정, 권영상, 김달래, 김경철, 임윤경. 3차원 로봇 맥 영상 분석기의 5단계 가압 맥파 분석에 의한 고혈압 환자의 현맥(弦脈) 연구. 경락경혈학회지. 2010 ; 27(1) : 1-12.
  5. 이주호, 최환수, 김철중. 맥상 분류 기준에 대한 방법론적 고찰-瀕湖脈學을 중심으로-. 한국한의학연구원논문집. 2004 ; 10(1) : 49-61.
  6. 한봉재. 脈診에 관한 圖像연구. 한국한의학연구원논문집. 2009 ; 15(2) : 101-9.
  7. 김석하, 홍섭희, 정현정, 박원환. 전자맥진기의 맥상과 고전의 제맥체상에 관한 연구(I). 대한한의진단학회지. 2009 ; 13(1) : 37-45.
  8. 김재욱, 신상훈. 맥진 알고리즘 개발. 電子工學會誌. 2010 ; 37(7) : 32-41.
  9. 김종열, 김경요, 고기덕. 맥진기의 문제점과 개선방안에 관한 연구. 대한한의진단학회지. 1999 ; 3(1) : 28-36.
  10. 김은혜, 김병수, 강정수. 희수식 전자 맥진기의 재조명. 대전대학교 한의학연구소 논문집. 2009 ; 18(2) : 37-45.
  11. 유현희, 이시우, 이전, 이유정, 김종열. 문헌을 통한 맥상의 물리적 요소 분석. 동의생리병리학회지. 2007 ; 21(6) : 1381-7.
  12. 許浚. 東醫寶鑑. 서울 : 南山堂. 2009 : 292.
  13. Lee HS, Lee YB, Shin YS, Kim HJ, Seo JC, Lee JM et el. A pilot study on reliability of pulse diagnosis in eight-constitution medicine. The Korean Journal of Meridian & Acupoint. 2005 ; 22(4) : 1-8.