Reliability of the Joint Neutral Position and Measurement Methods of the Ankle Joint Complex Range of Motion

발목관절 복합체의 가동범위 측정을 위한 중립위치와 측정방법의 신뢰도

  • Hong, Wan-Sung (Department of Physical Therapy, Dong-Nam Health College) ;
  • Kim, Gi-Won (Department of Physical Therapy, Suwon Women's College)
  • 홍완성 (동남보건대학 물리치료과) ;
  • 김기원 (수원여자대학 물리치료과)
  • Received : 2011.04.16
  • Accepted : 2011.07.21
  • Published : 2011.08.25

Abstract

Purpose: To determine the correct measurement methods of the ankle joint complex range of motion for measuring the neutral position and evaluate the rater reliability. In addition, the impact of training on the rater reliability was also assessed. Methods: The subjects were eleven healthy women, who were evaluated by two physical therapists and one physical therapist recorded the results of the study. Standard goniometer was used as the measurement tool. The ankle and subtalar joint neutral position and the active range of motion of the ankle and subtalar joint were measured. Intra-rater reliability and inter-rater reliability measures were analyzed with intraclass correlation coefficients. Results: Intra-rater reliability and inter-rater reliability ranged from high to medium for the neutral position of the ankle joint complex. Intra-rater reliability for dorsiflexion and plantarflexion measurements was medium, while the inter-rater reliability was high. The range of motion of the subtalar joint was measured, and the intra-rater reliability and inter-rater reliability were low and medium, respectively Also, the intra-rater reliability was increased with formal training of the measurement techniques. Intra-rater reliability was reduced in case the raters had not undertaken the training. Conclusion: In summary, the results obtained with the measurement tools and joint measurement of position, indicate the consistency of repeated measurements made by the same observers. Under the same circumstances along with repetition of the same measurement technique during training caused an increase in the rater reliability of formally trained raters.

Keywords

References

  1. van den Bogrert AJ, Smith GD, Nigg BM. In vivo determination of the anatomical axes of the ankle joint complex: an optimization approach. J Biomech. 1994;27(12): 1477-88. https://doi.org/10.1016/0021-9290(94)90197-X
  2. Neumann DA. Kinesiology of the musculaoskeletal system: Foundations for physical rehabilitation. 2nd ed. St Louis, Mosby, 2010:574-4.
  3. Moseley AM, Crosbie J, Adams R. Normative data for passive ankle plantarflexion-dorsiflexion flexibility. Clin Biomech. 2001;16(6):514-21. https://doi.org/10.1016/S0268-0033(01)00030-4
  4. Leardini A, Stagni R, O'Connor JJ. Mobility of the subtallar joint in the intact ankle complex. J Biomech. 2001;34(6): 805-9. https://doi.org/10.1016/S0021-9290(01)00031-8
  5. Leardini A, O'Connor JJ, Catani F et al. A geometric model of the human ankle joint. J Biomech. 1999;32(6):585-91. https://doi.org/10.1016/S0021-9290(99)00022-6
  6. Goto A, Moritomo H, Itohara T et al. Three-dimensional in vivo kinematics of the subtalar joint during dorsi- plantarflexion and inversion-eversion. Foot Ankle Int. 2009;30(5): 432-8. https://doi.org/10.3113/FAI.2009.0432
  7. Stacpoole-Shea S, Shea G, Otago L et al. Instrumentation considerations of a clinical and a computerized technique for the measurement of foot angles. J Foot Ankle Surg. 1998;37(5):410-5. https://doi.org/10.1016/S1067-2516(98)80050-1
  8. Banskota B, Lewis J, Hossain M et al. Estimation of the accuracy of joint mobility assessment in a group of health professionals. Eur J Orthop Surg Traumatol. 2008;18(4): 287-9. https://doi.org/10.1007/s00590-008-0301-1
  9. Lea RD, Gerhardt JJ. Range-of-motion measurements. J Bone Joint Surg Am. 1995;77(5):784-98.
  10. Jordan K, Dziedzic K, Mullis R et al. The development of three-dimensional range of motion measurement systems for clinical practice. Rheumatology. 200140(10):1081-4. https://doi.org/10.1093/rheumatology/40.10.1081
  11. Kim KH, Lee HD, Lee SC. Reliability of Goniometirc Measurements at the Lower Extremity Joint. Korean Society for measurement and evaluation in physical education and sport science. 2006;8(2):13-25.
  12. Boone DC, Azen SP. Normal range of motion of joints in male subjects. J Bone Joint Surg Am. 1979;61(5):756-9.
  13. Gajdosik RL, Bohannon RW. Clinical measurement of range of motion. Review of goniometry emphasizing reliability and validity. Phys Ther. 1987;67(12):1867-72.
  14. Wright JG, Feinstein AR. Improving the reliability of orthopaedic measurements. J Bone Joint Surg Br. 1992;74(2): 287-91.
  15. Aydog E, Aydog ST, Cakci A et al. Reliability of isokinetic ankle inversion- and eversion-strength measurement in neutral foot position, using the Biodex dynamometer. Knee Surg Sports Traumatol Arthrosc. 200412(5):478-81. https://doi.org/10.1007/s00167-004-0530-8
  16. Thoms V, Rome K. Effect of subject position on the reliability of measurement of active ankle joint dorsiflexion. The Foot. 1997;7(3):153-58. https://doi.org/10.1016/S0958-2592(97)90027-4
  17. Hong WS, Kim GW. Reliability of measurement devices for measuring the ankle joint motion. Korean J Orthop Man Ther. 2009;15(1):1-8.
  18. Kim GW, Hong WS. A study of measurement methods for subtalar joint motion. J Kor Soc Phys Ther. 2010; 22(4):57-64.
  19. Munro BH. Statistical methods for health care research. 3rd ed. New York, Lippincott Williams & Wilkins, 1997:249.
  20. Kim MH, Lee JH, Kim CK. The change in postural balance index by kinesio taping and muscle strength exercises on ankle joint. J Kor Soc Phys Ther. 2009;21(3):69-74.
  21. WrobelJS, Armstrong DG. Reliability and validity of current physical examination techniques of the foot and ankle. J Am Podiatr Med Assoc. 2008;98(3):197-206.
  22. Elveru RA, Rothstein JM, Lamb RL. Goniometric reliability in a clinical setting subtalar and ankle joint measurements. Phys Ther. 1988;68(5):672-7.
  23. Ogilvie SW, Rendall GC, Abboud RJ. Reliabilty of open kinetic chain subtalar joint measurement. The Foot. 1997;7(3):128-34. https://doi.org/10.1016/S0958-2592(97)90022-5
  24. Keenan AM, Bach TM. Clinicians' assessment of the hindfoot: A study of reliability. Foot Ankle Int. 2006;27(6): 451-60.
  25. Harvey L, Byak A, Ostrovskaya M et al. Reliability of a device designed to measure ankle mobility. Spinal Cord. 2003;41(10):559-62. https://doi.org/10.1038/sj.sc.3101486
  26. Pnadya S, Florence JM, King WM et al. Reliability of goniometric measurements in patients with duchenne muscular dystrophy. Phys Ther. 1985;65(9):1339-42.
  27. Menadue C, Raymond J, Kilbreath SL et al. Reliability of two goniometric methods of measuring active inversion and eversion range of motion at ankle. BMC Musculoskelet Disord. 2006;7:60. https://doi.org/10.1186/1471-2474-7-60
  28. Menz HB. Clinical hindfoot measurement: a critical review of the literature. The Foot. 1995;5(2):57-64. https://doi.org/10.1016/0958-2592(95)90012-8