A Study on Full and Part Load Operations of a Biogas-fired Gas Turbine Combined Heat and Power System

바이오 가스를 사용하는 가스터빈 열병합 시스템의 전부하 및 부분부하 운전특성 해석

  • Received : 2010.10.15
  • Accepted : 2011.02.15
  • Published : 2011.04.01

Abstract

This study analyzed the influence of firing biogas on the performance and operation of a gas turbine combined heat and power (CHP) system. A reference CHP system designed with natural gas fuel was set up and off-design simulation was made to investigate the impact of firing biogas in the system. Changes in critical operating parameters such as compressor surge margin and turbine blade temperature caused by firing biogas were examined, and a couple of operating schemes to mitigate their changes were simulated. Part load operation of the biogas-fired system was compared with that of natural-gas fired system, and it was found that as long as the two system produce the same electric power output, they exhibit nearly the same heat recovery.

Keywords

References

  1. Bruno, J. C. and Coronas, A,. 2004, “Distributed Generation of Energy using Micro Gas Turbines : Polygeneration Systems and Fuel Flexibility,” Proceedings of the International Conference on Renewable Energy and Power Quality (ICREPQ’04).
  2. Lepszy, S. and Chmielniak, T., 2008, “Analysis of The Biomass Integrated Combined Cycles with Two Different Structures of Gas Turbines,” ASME paper GT2008-50317.
  3. Rodrigues M, Walter A and Faaij A, 2007, “Performance Evaluation of Atmospheric Biomass Integrated Gasifier Combined Cycle Systems Under Different Strategies for The Use of Low Calorific Gases,” Energy Coversion and Management. Vol. 48, pp. 1289-1301. https://doi.org/10.1016/j.enconman.2006.09.016
  4. Colantoni, S., Gatta, S. D., De Prosperis, R., Russo, A., Fantozzi, F. and Desideri, U., 2009, “Gas Turbine Fired with Biomass Pyrolysis Syngas : Analysis of The Overheating of Hot Gas Path Components,”
  5. 김동섭, 노승탁, 1995, “단축 가스터빈 엔진의 부분부하 성능해석,” 춘계학술대회논문집, pp. 492-497.
  6. 김동섭, 2003, “배열 이용도를 고려한 가스터빈 발전시스템의 부분부하 성능 비교분석,” 유체기계 저널, 제6권, 제3호, pp. 28-135. https://doi.org/10.5293/KFMA.2003.6.3.028
  7. Enter Software. GateCycle ver 6.0, 2006.
  8. Palmer, C.A. and Erbes, M.R., 1994, “Simulation Methods Used to Analyze The Performance of the GE PG6541B Gas Turbine Utilizing Low Heating Value Fuels,” ASME IGTI Cogen-Turbo, IGTI-Vol. 9 pp. 337-346.
  9. 최승주, 2006, “두산중공업의 소형가스터빈 개발,” 대한기계학회저널, 제46권, 제10호, pp.41-47.
  10. Oluyede, E. and Phillips, J. N., 2007, “Fundamental impact of firing syngas in gas turbines,” ASME paper GT2007-27385.
  11. Erbes, M. R. and Gay, R. R., 1989, “GATE/CYCLE Predictions of The Off Design Performance of Combined Cycle Power Plants,”Simulation of Thermal Energy Systems, ASME AES Vol. 6/HTD Vol. 124, pp. 43-51.
  12. Brun, K. and Simmons, H., “Aerodynamic Instability and Life Limiting Effects of Inlet and Interstage Water Injection into Gas Turbines,” ASME paper GT2005-68007.