Fluoroscopic Radiation Exposure during Percutaneous Kyphoplasty

  • Choi, Hyun-Chul (Department of Neurosurgery & Spine Center, Sacred Heart Hospital, College of Medicine, The Hallym University of Korea)
  • Received : 2010.05.19
  • Accepted : 2010.12.31
  • Published : 2011.01.28

Abstract

Objective: The author measured levels of fluoroscopic radiation exposure to the surgeon's body based on the different beam directions during kyphoplasty. Methods: This is an observational study. A series of 84 patients (96 vertebral bodies) were treated with kyphoplasty over one year. The patients were divided into four groups based on the horizontal and vertical directions of the X-Ray beams. We measured radiation exposure with the seven dosimetry badges which were worn by the surgeon in each group (total of 28 badges). Twenty-four procedures were measured in each group. Cumulative dose and dose rates were compared between groups. Results: Fluoroscopic radiation is received by the operator in real-time for approximately 50% (half) of the operation time. Thyroid protectors and lead aprons can block radiation almost completely. The largest dose was received in the chest irrespective of beam directions. The lowest level of radiation were received when X-ray tube was away from the surgeon and beneath the bed (dose rate of head, neck, chest, abdomen and knee: 0.2986, 0.2828, 0.9711, 0.8977, 0.8168 mSv, respectively). The radiation differences between each group were approximately 2.7-10 folds. Conclusion: When fluoroscopic guided-KP is performed, the X-Ray tube should be positioned on the opposite side of the operator and below the table, otherwise the received radiation to the surgeon's body would be 2.7-10 times higher than such condition.

Keywords

References

  1. Bindal RK, Glaze S, Ognoskie M, Tunner V, Malone R, Ghosh S : Surgeon and patient radiation exposure in minimally invasive transforaminal lumbar interbody fusion. J Neurosurg Spine 9 : 570-573, 2008 https://doi.org/10.3171/SPI.2008.4.08182
  2. Chida K, Saito H, Otani H, Kohzuki M, Takahashi S, Yamada S, et al. : Relationship between fluoroscopic time, dose-area product, body weight, and maximum radiation skin dose in cardiac interventional procedures. AJR Am J Roentgenol 186 : 774-778, 2006 https://doi.org/10.2214/AJR.04.1653
  3. Cousins C, Sharp C : Medical interventional procedures-reducing the radiation risks. Clin Radiol 59 : 468-473, 2004 https://doi.org/10.1016/j.crad.2003.11.014
  4. D'Ercole L, Mantovani L, Thyrion FZ, Bocchiola M, Azzaretti A, Di Maria F, et al. : A study on maximum skin dose in cerebral embolization procedures. AJNR Am J Neuroradiol 28 : 503-507, 2007
  5. Izadpanah K, Konrad G, Sudkamp NP, Oberst M : Computer navigation in balloon kyphoplasty reduces the intraoperative radiation exposure. Spine (Phila Pa 1976) 34 : 1325-1329, 2009 https://doi.org/10.1097/BRS.0b013e3181a18529
  6. Kallmes DF, O E, Roy SS, Piccolo RG, Marx WF, Lee JK, et al. : Radiation dose to the operator during vertebroplasty : prospective comparison of the use of 1-cc syringes versus an injection device. AJNR Am J Neuroradiol 24 : 1257-1260, 2003
  7. Kim CW, Lee YP, Taylor W, Oygar A, Kim WK : Use of navigation-assisted fluoroscopy to decrease radiation exposure during minimally in vasive spine surgery. Spine J 8 : 584-590, 2008 https://doi.org/10.1016/j.spinee.2006.12.012
  8. Kruger R, Faciszewski T : Radiation dose reduction to medical staff during vertebroplasty : a review of techniques and methods to mitigate occupational dose. Spine (Phila Pa 1976) 28 : 1608-1613, 2003
  9. Mehdizade A, Lovblad KO, Wilhelm KE, Somon T, Wetzel SG, Kelekis AD, et al. : Radiation dose in vertebroplasty. Neuroradiology 46 : 243-245, 2004 https://doi.org/10.1007/s00234-003-1156-0
  10. Mroz TE, Yamashita T, Davros WJ, Lieberman IH : Radiation exposure to the surgeon and the patient during kyphoplasty. J Spinal Disord Tech 21 : 96-100, 2008 https://doi.org/10.1097/BSD.0b013e31805fe9e1
  11. Muller LP, Suffner J, Wenda K, Mohr W, Rommens PM : Radiation exposure to the hands and the thyroid of the surgeon during intramedullary nailing. Injury 29 : 461-468, 1998 https://doi.org/10.1016/S0020-1383(98)00088-6
  12. Perisinakis K, Damilakis J, Theocharopoulos N, Papadokostakis G, Hadjipavlou A, Gourtsoyiannis N : Patient exposure and associated radiation risks from fluoroscopically guided vertebroplasty or kyphoplasty. Radiology 232 : 701-707, 2004 https://doi.org/10.1148/radiol.2323031412
  13. Rampersaud YR, Foley KT, Shen AC, Williams S, Solomito M : Radiation exposure to the spine surgeon during fluoroscopically assisted pedicle screw insertion. Spine (Phila Pa 1976) 25 : 2637-2645, 2000 https://doi.org/10.1097/00007632-200010150-00016
  14. Seibert JA : Vertebroplasty and kyphoplasty : do fluoroscopy operators know about radiation dose, and should they want to know? Radiology 232 : 633-634, 2004 https://doi.org/10.1148/radiol.2323040968
  15. Synowitz M, Kiwit J : Surgeon's radiation exposure during percutaneous vertebroplasty. J Neurosurg Spine 4 : 106-109, 2006 https://doi.org/10.3171/spi.2006.4.2.106
  16. The National Council on Radiation Protection and Measurements. Radiation protection in in educational institutions (National Council on Radiation Protection and Measurements Web site). July, 2006. Available at : http://www.ncrponline.org/Docs_in_Review/NCRP0640.pdf. Accessed 01/05, 2007.
  17. Recommendations of the International Commission on Radiologic Protection. ICRP Publication 26. Bethesda, MD : International Commission on Radiological Protection; 1977 : 1.
  18. Recommendations on limits for exposure to ionizing radiation. Bethesda, MD : National Council on Radiation Protection and Measurements, 1987 : 91.
  19. Recommendations of the International Commission on Radiologic Protection. ICRP Publication 60. Bethesda, MD : International Commission on Radiological Protection; 1991 : 21.
  20. Wagner LK, Archer BR. Minimizing Risks From Fluoroscopic X Rays; Bioeffects, Instrumentation, and Examination. 3rd ed. The Woodlands, TX : Partners in radiation management; 2000
  21. Mahesh M : Fluoroscopy : patient radiation exposure issues. Radiographics 21 : 1033-1045, 2001 https://doi.org/10.1148/radiographics.21.4.g01jl271033

Cited by

  1. Radiation Safety for Pain Physicians vol.25, pp.2, 2011, https://doi.org/10.3344/kjp.2012.25.2.130
  2. Radiation Exposure to the Spine Surgeon in Lumbar and Thoracolumbar Fusions With the Use of an Intraoperative Computed Tomographic 3-Dimensional Imaging System vol.37, pp.17, 2012, https://doi.org/10.1097/brs.0b013e31825786d8
  3. A Case of Dengue Fever Complicated by Retinitis vol.44, pp.4, 2011, https://doi.org/10.3947/ic.2012.44.4.307
  4. A Case of Dengue Fever with Maculopathy vol.44, pp.6, 2011, https://doi.org/10.3947/ic.2012.44.6.504
  5. Significant Improvement of Puncture Accuracy and Fluoroscopy Reduction in Percutaneous Transforaminal Endoscopic Discectomy With Novel Lumbar Location System : Preliminary Report of Prospective Hello vol.94, pp.49, 2011, https://doi.org/10.1097/md.0000000000002189
  6. Is lead shielding of patients necessary during fluoroscopic procedures? A study based on kyphoplasty vol.47, pp.1, 2011, https://doi.org/10.1007/s00256-017-2756-9
  7. Radiation exposure to the surgeon during minimally invasive spine procedures is directly estimated by patient dose vol.27, pp.8, 2011, https://doi.org/10.1007/s00586-018-5653-6
  8. Reduction of Radiation Exposure by Modifying Imaging Manner and Fluoroscopic Settings during Percutaneous Pedicle Screw Insertion vol.64, pp.6, 2011, https://doi.org/10.3340/jkns.2020.0338