DOI QR코드

DOI QR Code

Design and Implementation of IEEE 11073/HL7 Translation Gateway Based on U-Healthcare Application Service for M2M

M2M을 위한 U-헬스케어 응용 서비스 기반 IEEE 11073/HL7 변환 게이트웨이 설계 및 구현

  • 천승만 (경북대학교 전자전기컴퓨터학부 정보통신망 신기술 연구실) ;
  • 나재욱 (경북대학교 전자전기컴퓨터학부 정보통신망 신기술 연구실) ;
  • 박종태 (경북대학교 전자전기컴퓨터학부 정보통신망 신기술 연구실)
  • Received : 2010.11.30
  • Accepted : 2011.03.18
  • Published : 2011.03.31

Abstract

As the 21st century paradigm of healthcare service changes from post-therapeutic treatment to disease prevention and management in advance, the M2M-based u-healthcare application service is increasingly important. M2M-based u-healthcare application service uses mobile handsets equipped with sensors to measure vital information, and the medical staff in remote locations can manage the health of the patient or the public in real time. In this paper, IEEE/HL7 translation gateway, utilizing the gateway based on M2M u-healthcare application service structure, which is based on international standards, has been designed and implemented. Specifically, the gateway between ISO/IEEE 11073 standards and ANSI HL7 has been developed. The former defines the protocol for the exchange of information between the agent device and the manger devices for measuring and handling biological signal, and the latter defines the application layer protocol for the exchange of various healthcare information systems. Finally, in order to demonstrate the functionality of the proposed architecture, the M2M-based U-healthcare application service based on IEEE/HL7 translation gateway, utilizing the gateway, has been developed which can measure, collect and process a variety of vital signs such as ECG or SpO2.

21세기 의료서비스 패러다임이 사후 치료에서 사전 예방 및 관리 중심으로 바뀜에 따라 M2M 기반의 U-헬스케어 응용 서비스가 점차로 중요 해지고 있다. M2M 기반의 U-헬스케어 응용 서비스는 휴대단말에 장착된 센서를 통해 생체 정보를 측정하여, 원격지에 있는 의료진이 만성 질환자 혹은 일반인의 건강 상태를 실시간에 관리가 가능 하도록 한다. 본 논문에서는 국제 표준 기반의 M2M을 위한 U-헬스케어 응용 서비스 기반 IEEE 11073/HL7 변환게이트웨이 구조를 설계 및 구현 하였다. 구체적으로, 생체 신호 측정을 위한 에이전트 장치와 처리를 위한 매니저 장치간의 생체 정보 교환을 위한 ISO/IEEE 11073 표준과 다양한 보건의료 정보시스템 간의 데이터 교환을 위한 ANSI HL7 간 프로토콜 변환 게이트웨이를 설계 및 구현 하였다. 최종적으로 제안된 구조의 기능 검증을 위해, 개발된 게이트웨이를 사용하여 생체신호측정 센서 (ECG, SpO2)를 활용하여 측정, 수집 및 처리하는 M2M을 위한 U-헬스케어 응용 서비스 가반 IEEE/HL7 변환게이트웨이를 개발하였다.

Keywords

References

  1. H. Mitsui, H. Kambe, and H. Koizumi, "Student Experiments for Learning Basic M2M Technologies by Implementing Sensor Networks System", in proc., ITHET 2010, Apr. 29-May 1 2010.
  2. A. Lymperis and A. Dittmar, "Advanced Wearable Health Systems and Applications, Research and Development Efforts in the European Union," IEEE Eng. Med. Biol. Mag., Vol.26, No.3, pp.29-33, May/Jun., 2007.
  3. Y. Hao and R. Foster, "Wireless Body Sensor Networks for Health Monitoring Applications," Phys. Meas., Vol.29, pp.R27-R56, Nov., 2008. https://doi.org/10.1088/0967-3334/29/11/R01
  4. V. Shnauder et al., "Sensor Networks for Medical Care," Harvard Univ. tech. rep. TR-08-05, Apr., 2005.
  5. T. Mon, "HL7 PHR System Funcational Model and Standard," HIMSS Annual Conference, April, 2009.
  6. The Institute of Electrical and Electronics Engineers, ISO/IEEE 11073-20601 Standard for Health Informatics - Personal health device communication - Application profile - Optimized exchange protocol. ISO/IEEE 11073-20601.
  7. Health Level 7 Inc., "HL7 Resource Library," 2005, http://www.hl7.org.
  8. H. Cao, V. Leung, C. Chow, and H. Chan, "Enabling Technologies for Wireless Body Area Network: A Survey and Outlook," IEEE Comm. Magazine, vol. 47, iss. 12, pp. 84-93, Dec. 2009.
  9. M. Joo, S. Cho, Y. Lee, "Trends in Standards on Medical Information," J.kor. Ins. Inf. Sci. and Eng., vol. 26, no. 6, pp. 70-79, 2008.
  10. M. Li and K. Ren, "Data Security and Privacy in Wireless Body Area Networks," IEEE Wireless Comm., vol. 17, no. 1, pp. 51-58, Feb. 2010. https://doi.org/10.1109/MWC.2010.5416350
  11. The Continua Health Alliance at http://www.continuaalliance.org
  12. B. Piniewski, J. Muskens, et al., "Empowering Healthcare Patients with Smart Technology," IEEE Computer Society, Vol.43, iss.7, pp.27-34, July, 2010.
  13. R. Carroll, R. Cnossen, M. Schnell, and D. Simons, "Continua: An Interoperable Personal Healthcare Ecosystem," IEEE Pervasive Computing, Vol.6, No.4, pp.90-94, Oct.-Dec., 2007.
  14. The Institute of Electrical and Electronics Engineers, ISO/IEEE 11073-20601 Standard for Health Informatics - Personal health device communication - Device Specialization - Pulse Oximeter. ISO/IEEE 11073-10404.
  15. The Institute of Electrical and Electronics Engineers, ISO/IEEE 11073-20601 Standard for Health Informatics - Personal health device communication - Device Specialization - Heart Rate Monitor. ISO/IEEE 11073-10406.
  16. R. H. Dolin, L. Alschuler, S. Boyer, C. Beebe, F. M. Behlen, et al., "HL7 Clinical Document Architecture, release 2," J. Am. Med. Inform. Assoc., 13(1), pp.30-39, 2005.

Cited by

  1. A Design of High Efficiency Microwave Wireless Power Acceptor IC vol.62, pp.8, 2013, https://doi.org/10.5370/KIEE.2013.62.8.1125