DOI QR코드

DOI QR Code

Comparison of System Performances of Hot-gas Bypass and Compressor Variable Speed Control of Water Coolers for Machine Tools

핫가스 바이패스 및 압축기 가변속 제어에 의한 공작기계용 수냉각기의 성능 비교

  • Jeong, Seok-Kwon (Dept. of Refrigeration and Air-conditioning Engineering, Pukyong National University) ;
  • Lee, Dan-Bi (Graduate School of Refrigeration and Air-conditioning Eng. Pukyong National University) ;
  • Yoon, Jung-In (Dept. of Refrigeration and Air-conditioning Engineering, Pukyong National University)
  • 정석권 (부경대학교 냉동공조공학과) ;
  • 이단비 (부경대학교 대학원 냉동공조공학과) ;
  • 윤정인 (부경대학교 냉동공조공학과)
  • Received : 2011.07.25
  • Accepted : 2011.10.26
  • Published : 2012.01.10

Abstract

Recently, the needs of system performances such as working speed and processing accuracy in machine tools have been increased. Especially, the speed increment generates harmful heat at both moving part of the machine tools and handicrafts. The heat is a main drawback to progress accuracy of the processing. Hence, a cooler system to control temperature is inevitable for the machine tools. In general, two representative control schemes, hot-gas bypass and variable speed control of a compressor, have been adopted in the water cooler system. In this paper, comparisons of system performances according to the control schemes in a cooler for machine tools were conducted in detail. Each proportional-integral feedback controller for the two different control systems is designed. The system performances, especially the temperature control accuracy and coefficient of performance which is a criterion of energy saving, were mainly analyzed through various experiments using 1RT water cooler system with different two types of control scheme. These evaluations will provide useful information to choose suitable water cooler system for the engineers who design controllers of the cooler system for machine tools.

Keywords

References

  1. Lee, S. W., Yeom, H. K., and Park, K. J., 2009, Performance of Hot Gas Bypass Type Oil Cooler System, Journal of Korean Society for Precision Engineering, Vol. 26, No. 3, pp. 73-80.
  2. Lee, S. W., Yeom, H. K., and Lee, H. K., 2011, Improvement of Temperature Accuracy in Oil Cooler Systems with Gas Bypass, International Journal of Precision Engineering and Manufacturing, Vol. 12, No. 1, pp. 39-45. https://doi.org/10.1007/s12541-011-0005-z
  3. Yaqub, M., Zubair, S. M., and Khan, J.-ur-R., 2000, Performance Evaluation of Hot-gas Bypass Capacity Control Scheme for Refrigeration and Air-conditioning Systems, Energy, Vol. 25, pp. 543-561. https://doi.org/10.1016/S0360-5442(00)00004-9
  4. Jung, Y. M., Byun, J. Y., Yoon, J. I., and Jeong, S. K., 2009, A Study on High Precision Temperature Control of an Oil Cooler for Machine Tools Using Hot-gas Bypass Method, Journal of the Korean Society of Marine Engineering, Vol. 33, No. 7, pp. 1003-1011. https://doi.org/10.5916/jkosme.2009.33.7.1003
  5. Byun, J. Y. and Jeong, S. K., 2010, Design of PI and Feedforward Controller for Precise Temperature Control of Oil Cooler System, Journal of the Korean Society for Power System Engineering, Vol. 14, No. 6, pp. 89-95.
  6. Jeong, S. K., Byun, J. Y., Kim, S. H., and Yoon, J. I., 2011, Precise Temperature Control of Oil Coolers with Hot-gas Bypass Manner for Machine Tools Based on PI and Feedforward Control, SAREK, Vol. 23, No. 2, pp. 111-119.
  7. Beak, S. M., Choi, J. H., Byun, J. Y., Moon, C. G., Lee, H. S., Jeong, S. K., and Yoon, J. I., 2009, Characteristics of Temperature Control by Hot-gas Bypass Flow Rate on Industrial Water Cooler, Journal of the Korean Society of Marine Engineering, Vol. 33, No. 8, pp. 1129-1136. https://doi.org/10.5916/jkosme.2009.33.8.1129
  8. Beak, S. M., Moon, C. G., Kim, H. W., Jeong, S. K., and Yoon, J. I., 2010, Characteristics of Capacity Control of Variable Speed Water Cooler with the Electronic Expansion Valve Open/ Close Degree, Journal of the Korean Society of Marine Engineering, Vol. 34, No. 2, pp. 282-288. https://doi.org/10.5916/jkosme.2010.34.2.282
  9. Beak, S. M., Moon, C. G., Kim, E. P., Jeong, S. K., and Yoon, J. I., 2011, The Characteristic Study of Capacity Control of an Industrial Cooler Using an Inverter Compressor with Varing the Ambient Temperatures, Journal of the Korean Society of Marine Engineering, Vol. 35, No. 2, pp. 238-243. https://doi.org/10.5916/jkosme.2011.35.2.238
  10. Beak, S. M., Moon, C. G., Kim, E. P., Jeong, S. K., and Yoon, J. I., 2011, Characteristics of On-off Control and Hot-Gas Bypass Control in an Industrial cooler, Journal of the Korean Society of Marine Engineering, Vol. 35, No. 4, pp. 429-435. https://doi.org/10.5916/jkosme.2011.35.4.429
  11. Beak, S. M., Choi, J. H., Byun, J. Y., Moon, C. G., Jeong, S. K., and Yoon, J. I., 2010, Characteristics of Precise Temperature Control of Industrial Cooler on Thermal Load, Journal of the Korean Society for Power System Engineering, Vol. 14, No. 2, pp. 34-39.
  12. Beak, S. M., Moon, C. G., Yoon, J. I., Jeong, S. K., and Kim, E. P., 2011, The characteristics of capacity control using a variable speed compressor in an industrial cooler, Journal of the Korean Society for Power System Engineering, Vol. 15, No. 2, pp. 37-41.
  13. Li, H., You, S. S., Yoon, J. I., and Jeong, S. K., 2008, An Empirical Model for Independent Control of Variable Speed Refrigeration System, Applied Thermal Engineering, Vol. 28, pp. 1918-1924. https://doi.org/10.1016/j.applthermaleng.2007.12.008
  14. Li, H., You, S. S., and Jeong, S. K., 2009, Feedforward Control of Capacity and Superheat for a Variable Speed Refrigeration System, Applied Thermal Engineering, Vol. 29, pp. 1067-1074. https://doi.org/10.1016/j.applthermaleng.2008.05.022

Cited by

  1. An Experimental Study on the Performance Characteristics of Hot-gas and Liquid Bypass Heat Pump Systems for Capacity Modulation vol.25, pp.3, 2013, https://doi.org/10.6110/KJACR.2013.25.3.137