Performance Evaluation of an Integrated Starter-Alternator with an IPM Synchronous Machine under Sensor-less Operation

  • Xu, Zhuang (School of Electrical Eng. and Automation, Harbin Institute of Technology) ;
  • Rahman, M.F. (School of Electrical Engineering and telecommunications, The University of New South Wales) ;
  • Wang, G. (School of Electrical Eng. and Automation, Harbin Institute of Technology) ;
  • Xu, Dianguo (School of Electrical Eng. and Automation, Harbin Institute of Technology)
  • Received : 2011.08.30
  • Accepted : 2011.12.04
  • Published : 2012.01.20

Abstract

This paper presents performance evaluation of an Integrated Starter-Alternator (ISA) prototype with an Interior Permanent Magnet (IPM) synchronous machine under sensor-less operation. To attain a high starting torque at zero speed and in subsequent extremely low speed range, a hybrid signal injection method is proposed. At higher speed, an improved stator flux observer is used for the stator flux estimation. This observer is able to produce accurately-estimated stator flux linkage for high performance Direct Torque and Flux Control (DTFC) implementation. The sensor-less DTFC IPM synchronous machine drive takes full advantage of the capacity of the power converter and fulfills the control specifications for the ISA. The trajectory control algorithm responds rapidly and in a well behaved manner over a wide range of operating conditions. The experimental results verify the feasibility and advantages of the system.

Keywords

References

  1. J. G. Kassakian, J. M. Miller, and N. Traub, "Automotive electronics power up," Spectrum, IEEE, Vol. 37, No. 5, pp. 34-39, May 2000.
  2. E. C. Lovelace, T. M. Jahns, J. L. Kritley Jr., and J. H. Lang, "An Interior PM Starter/Alternator for Automotive Applications," in Proc. International Conference on Electric machines(ICEM'98), Vol. 1, 1998.
  3. E. C. Lovelace, T. M. Jahns, J. Wai, T. Keim, J. H. Lang, D. D. Wentzloff, F. Leonardi, and J. M. Miller, "Design and experimental verification of a direct-drive interior PM synchronous machine using a saturable lumped parameter model," in Proc. Ind. Appl. Conf., 37th IAS Annual Meeting, Vol. 4, pp. 2486-2492, 2002.
  4. R. Dutta, M. F. Rahman, and M. A. Rahman, "An IPM machine with segmented magnet rotor for integrated starter alternator," In 3rd International Conference on Electrical and Computer engineering, 2004.
  5. R. Dutta and M. F. Rahman, "A segmented magnet interior permanent magnet machine with wide constant power range for application in hybrid vehicles," in Proc. 2005 IEEE Conf. Veh. Power Propulsion (VPP), pp. 288-293, 2005.
  6. M. F. Rahman, Md. E. Haque, Lixin Tang, and Limin Zhong, "Problems associated with the direct torque control of an interior permanent-magnet synchronous motor drive and their remedies," IEEE Trans. Ind. Electron., Vol. 51, No. 4, pp. 799-809, Aug. 2004. https://doi.org/10.1109/TIE.2004.831728
  7. M. E. Haque, L. Zhong, and M. F. Rahman, "A sensorless initial rotor position estimation scheme for a direct torque controlled interior permanent magnet synchronous motor drive," IEEE Tran. Power Electron., Vol. 18, pp. 1376-1383, Nov. 2003.
  8. L. A. Jones and J. H. Lang, "A state observer for the permanent-magnet synchronous motor," IEEE Trans. Ind. Electron., Vol. 36, pp. 374-382, Aug. 1989. https://doi.org/10.1109/41.31500
  9. J. F. Moynihan, M. G. Egan, and J. M. D. Murphy, "The application of state observers in current regulated PM synchronous drives," in Industrial Electronics, Control and Instrumentation, 1994. IECON '94., 20th International Conference on, Vol. 1, pp. 20-25, 1994.
  10. C. Lascu, I. Boldea, and F. Blaabjerg, "A modified direct torque control for induction motor sensorless drive," IEEE Trans. Ind. Electron., Vol. 36, pp. 122-130, Jan./Feb. 2000.
  11. M. Elbuluk and C. Li, "Sliding mode observer for wide-speed sensorless control of PMSM drives," Industry Applications Conference, 2003. 38th IAS Annual Meeting. Conference Record, Vol.1, pp. 480-485, 2003.
  12. Z. Chen, M. Tomita, S. Doki, and S. Okuma, "An extended electromotive force model for sensorless control of interior permanent-magnet synchronous motors," IEEE Trans. Ind. Electron., Vol. 50, pp. 288-295, Apr. 2003. https://doi.org/10.1109/TIE.2003.809391
  13. S. Bolognani, R. Oboe, and M. Zigliotto, "Sensorless full-digital PMSM drive with EKF estimation of speed and rotor position," IEEE Trans. Ind. Electron., Vol. 46, pp. 184-191, Feb. 1999. https://doi.org/10.1109/41.744410
  14. L. Harnefors, "Speed estimation from noisy resolver signals," Sixth International Conference on Power Electronics and Variable Speed Drives, No. 429, pp. 279-282, 1996.
  15. Z. Xu and M. F. Rahman, "Direct torque and flux regulation of an IPM synchronous motor drive using variable control approach," IEEE Trans.Power Electron., Vol. 22, pp. 2487-2498, Nov. 2007. https://doi.org/10.1109/TPEL.2007.909208
  16. L. Zhong, M. F. Rahman, W. Y. Hu, and K. W. Lim, "A direct torque controlled interior permanent magnet synchronous motor drive incorporating field weakening," IEEE Trans. Ind. Applicat., Vol. 34, pp. 1246-1253, Nov./Dec. 1998. https://doi.org/10.1109/28.738985

Cited by

  1. Sensorless Control of Wound Rotor Synchronous Machines Based on High-frequency Signal Injection into the Stator Windings vol.13, pp.4, 2013, https://doi.org/10.6113/JPE.2013.13.4.669