Shear Strength Enhancement of Hollow PHC Pile Reinforced with Infilled Concrete and Shear Reinforcement

내부충전 콘크리트와 전단철근을 이용한 중공 PHC말뚝의 전단보강 효과

  • Received : 2011.11.08
  • Accepted : 2012.01.12
  • Published : 2012.02.29

Abstract

In order to improve the shear strength of conventional pre-tensioned spun high strength concrete (PHC) pile, concrete-infilled composite PHC (ICP) pile, a PHC pile reinforced by means of shear reinforcement and infilled concrete, is proposed. Two types of specimens were cast and tested according to KS (Korean Standards) to verify the shear strength enhancement of ICP pile. Based on the test results, it was found that the KS method was not suitable due to causing shear failure of ICP pile. However, shear strength enhancement was clearly verified. The obtained shear strength of the ICP pile was more than twice that of conventional PHC pile. In addition, the shear strength of ICP pile reinforced with longitudinal reinforcement was estimated to be more than 2.5 times greater than that of conventional PHC pile. The allowable shear force of ICP pile, which was determined by the allowable stress design process, indicated a large safety factor of more than 2.9 compared to the test results.

이 논문에서는 기존 PHC말뚝의 전단성능을 향상시키기 위하여 전단철근과 내부충전 콘크리트로 보강한 ICP 말뚝을 제안하였다. 허용응력 설계법을 바탕으로 전단철근 및 내부충전 콘크리트를 설계하였으며, 이를 바탕으로 2종류의 시험체를 제작하여 KS규격에 따라 전단시험을 수행하였다. 전단시험 결과, KS규격에 의거한 시험방법으로는 전단파괴를 얻을 수 없었으나, 제안된 방법에 의한 전단보강효과는 충분히 검증할 수 있었다. ICP말뚝 시험체의 전단 저항력은 기존 PHC말뚝에 비하여 평균 2배 이상으로 증진되는 것으로 나타났다. 또한 축방향 철근을 추가 보강한 ICP말뚝 시험체의 전단 저항력은 기존 PHC말뚝에 비하여 평균 2.5배 이상 증진되었다. 한편 허용응력설계법에 따라 결정된 ICP 말뚝의 허용 전단력에 비하여 시험으로 측정된 전단강도는 약 2.9 이상의 안전율을 갖는 것으로 나타났다.

Keywords

References

  1. 최승선, "PHC 말뚝의 콘크리트 고품질화를 위한 제언," 콘크리트학회논문집, 14권, 6호, 2002, 41 pp. https://doi.org/10.4334/JKCI.2002.14.1.041
  2. 천영수, 박종배, 심영종, "조립철근망을 사용한 PHC 말뚝과 기초판 접합부의 역학성능 검증 및 현장시공 사례," 콘크리트학회지, 22권, 5호, 2010, 71 pp.
  3. 한국원심력콘크리트공업협동조합, 파일 조업 통계, 2010.
  4. 송태언, "강관말뚝을 PHC말뚝으로 변경시 판단절차서," 쌍용건설기술 가을호, Vol. 48, pp. 32-36.
  5. 황영철, 조천환, "국내 말뚝기초의 현황과 발전방향, " 한국지반공학회지, 21권, 2호, 2005, pp. 10-11.
  6. 한국토질및기초기술사회, "강관말뚝과 PHC말뚝을 결합구로 용접시킨 매입형 복합말뚝(HPC : hybrid composite pile)의 설계 및 시공방법," 지반과 기술 가을호, 5권, 3권, pp. 33-37.
  7. 최진우, 주형중, 남정훈, 윤순종, "FRP-콘크리트 합성말뚝의 개발," 한국복합신소재구조학회 논문집, 1권, 2호, 2010, pp. 20-28.
  8. Pando, M., Filz, G., Dove, J., and Hopper, E., "Interface Shear Tests on FRP Composite Piles," ASCE International Deep Foundations Congress, Orlando, Florida, Vol. 2, 2002, pp. 1486-1500.
  9. 大岩健治郞, 富山勝三, 梁島郁, "기성 콘크리트 말뚝의 현상황," 주택기술정보, 75호, 1996, pp. 141-157.
  10. 한국콘크리트학회, " 콘크리트구조설계기준해설," 기문당, 2007, 523 pp.
  11. 한국콘크리트학회, 콘크리트구조설계기준해설, 부록 별도 설계법, 기문당, 2003, 405 pp.
  12. 대한토목학회, "도로교설계기준해설 제5, 8장 말뚝기초의 설계," 2008, 1008 pp.
  13. 류기송, "PHC 말뚝기초의 설계," 농공기술 학술논문, 43호, 1994, pp. 27-37.
  14. 한국도로공사, "도로설계 실무편람, 3장 구조물공," 1996, pp. 14-42.
  15. KS F 4306, "프리텐션 방식 원심력 고강도 콘크리트 말뚝," 2003, 51 pp.
  16. (주)IS동서 콘크리트 종합 카달로그, 2009, 24 pp.
  17. 한국콘크리트학회, "내부충전 합성 PHC 말뚝의 설계법 개발 및 성능평가," 2010, 144 pp.

Cited by

  1. Cyclic behavior of connection between footing and concrete-infilled composite PHC pile vol.50, pp.6, 2014, https://doi.org/10.12989/sem.2014.50.6.741
  2. Flexural Strength of PHC Pile Reinforced with Infilled Concrete, Transverse and Longitudinal Reinforcements vol.25, pp.1, 2013, https://doi.org/10.4334/JKCI.2013.25.1.091