DOI QR코드

DOI QR Code

Nano Structured Potentiometric Sensors Based on Polyaniline Conducting Polymer for Determination of Cr (VI)

  • Received : 2011.11.16
  • Accepted : 2012.01.09
  • Published : 2012.04.20

Abstract

In this paper, a potentiometric sensor based on polyaniline conducting polymer for potentiometric determination of Cr (VI) ions is reported. Polyaniline was synthesized electrochemically (cyclic voltammetry method) onto a micro pencil graphite electrode (0.7 mm diameter) in the presence of HCl and diphenylcarbazide (termed as (PGE/PAni/DPC). Some initial experiments were performed in order to find out the optimized conditions for preparation of the introduced Cr (VI) sensor electrode. The plot of E vs. log [Cr (VI)], showed a linear response in the range from $1.0{\times}10^{-6}$ to $1.0{\times}10^{-1}$ M. High repeatability with the detection limit of $8.0{\times}10^{-7}$ M was obtained.

Keywords

References

  1. Gomez, V.; Callao, M. P. Trends. Anal. Chem. 2006, 25, 1006. https://doi.org/10.1016/j.trac.2006.06.010
  2. Singh, A. K.; Gupta, V. K.; Gupta, B. Anal. Chim. Acta 2007, 585, 171.
  3. Kortenkamp, A.; Casadevall, M.; Faux, S. P.; Jenner, A.; Shayer, R. O. J.; Woodbridge, N.; O'Brien, P. Arch. Biochem. Biophys. 1996, 329, 199. https://doi.org/10.1006/abbi.1996.0209
  4. National Toxicology Program, Chromium Hexavalent Compounds; Ninth Report on Carcinogens, NTP, Department of Health and Human Services, 2000.
  5. Guertin, J.; Jacobs, J. A.; Avakian, C. P. Chromium (VI) Handbook, Written by Independent Environmental Technical Evaluation Group (IETEG); CRC press: 2005.
  6. Guell, R.; Fontas, C.; Salvado, V.; Antico, E. Anal. Chim. Acta 2007, 594, 162. https://doi.org/10.1016/j.aca.2007.05.041
  7. Katz, S. A.; Salem, H. The Biological and Environmental Chemistry of Chromium; VCH: New York, USA, 1994.
  8. Koryta, J.; Stulik, K. Ion Selective Electrodes; Cambridge University Press: Cambridge, 1983.
  9. Hassan, S. S. M.; Abbas, M. N.; Moustafa, G. E. A. Talanta 1996, 43, 797. https://doi.org/10.1016/0039-9140(95)01833-6
  10. Ardakani, M. M.; Dastanpour, A.; Salavati-Niasari, M. Microchim. Acta 2005, 150, 67. https://doi.org/10.1007/s00604-005-0319-6
  11. Choi, W. Y.; Minoura, N.; Moon, S. H. Talanta 2005, 66, 1254. https://doi.org/10.1016/j.talanta.2005.01.040
  12. Singh, L. P.; Bhatnagar, J. M.; Tanaka, S.; Tsue, H.; Mori, M. Anal. Chim. Acta 2005, 546, 199. https://doi.org/10.1016/j.aca.2005.04.068
  13. Hassan, S. S. M.; El-Shahawi, M. S.; Othman, A. M.; Mosaad, M. A. Anal. Sci. 2005, 21, 673. https://doi.org/10.2116/analsci.21.673
  14. Erturun, H. E. K.; Yilmaz, M.; Kilic, E. Sens. Actuators B 2007, 127, 497. https://doi.org/10.1016/j.snb.2007.05.003
  15. Choi, Y. W.; Moon, S. H. Environ. Monit. Asses 2001, 70, 167. https://doi.org/10.1023/A:1010674414809
  16. Choi, Y. W.; Moon, S. H. Environ. Monit. Asses 2004, 92, 163. https://doi.org/10.1023/B:EMAS.0000014512.18816.cb
  17. Luthra, V.; Singh, R.; Gupta, S. K.; Mansingh, A. Curr. Appl. Phys. 2003, 3, 219. https://doi.org/10.1016/S1567-1739(02)00205-5
  18. Kim, Y.; Kim, J. S.; Thieu, M. T.; Dinh, H. C.; Yeo, I. H.; Cho, W. I.; Mho, S. I. Bull. Korean Chem. Soc. 2010, 31(11), 3109. https://doi.org/10.5012/bkcs.2010.31.11.3109
  19. Iqbal, P.; Critchle, K.; Begum, S.; Attwoo, D.; Evan, S. D.; Jone, I. P.; Preec, J. A. J. Exper. Nanosci. 2006, 1(2), 143. https://doi.org/10.1080/17458080500504058
  20. Ansari, R.; Fallah Delavar, A.; Aliakbar, A.; Mohammad-khah, A. J. Solid. State. Electrochem. 2011, 16(3), 869.
  21. Ansari, R.; Fallah Delavar, A. J. Appl. Polym. Sci. 2009, 113, 2293. https://doi.org/10.1002/app.30239
  22. De Paoli, M. A.; Gazotti, W. A. J. Braz. Chem. Soc. 2002, 13, 410.
  23. Korostynska, O.; Arshak, K.; Gill, E.; Arshak, A. Sensors 2007, 7, 3027. https://doi.org/10.3390/s7123027
  24. Basavaraja, C.; Kim, N. R.; Jo, E. A.; Pierson, R.; Huh, D. S.; Venkataraman, A. Bull. Korean Chem. Soc. 2009, 30(11), 2701. https://doi.org/10.5012/bkcs.2009.30.11.2701
  25. Del Valle, M. A.; Diaaz, F. R.; Bodini, M. E.; Pizarro, T.; Cordova, R.; Gomez, H.; Schrebler, R. J. Appl. Electrochem. 1998, 28, 943. https://doi.org/10.1023/A:1003415805513
  26. Lindfors, T.; Ivaska, A. Anal. Chim. Acta 2001, 437, 171. https://doi.org/10.1016/S0003-2670(01)00996-5
  27. Zhang, X.; Manohar, S. K. Chem. Commun. 2004, 20, 2360.
  28. Zhang, L.; Zhang, L.; Wan, M.; Wei, Y. Synth. Met. 2006, 156, 454. https://doi.org/10.1016/j.synthmet.2006.01.011
  29. Qiu, H. J.; Wan, M. X.; Matthews, B.; Dai, L. M. Macromol. 2001, 34, 675. https://doi.org/10.1021/ma001525e
  30. Huang, J. Pure. Appl. Chem. 2006, 78(1), 15. https://doi.org/10.1351/pac200678010015
  31. Naoi, K.; Lien, M.; Smyrl, W. H. J. Electrochem. Soc. 1991, 138, 440. https://doi.org/10.1149/1.2085606
  32. Chiang, J. C.; MacDiarmid, A. G. Synth. Metals 1989, 13, 193.
  33. Wang, Y.; Tran, H. D.; Kaner, R. B. Macromo. Rapid. Commun. 2011, 32, 35. https://doi.org/10.1002/marc.201000280
  34. Willes, G. J.; Blaton, N. M.; Peeters, O. M.; Deranter, C. J. Anal. Chim. Acta 1977, 88, 345. https://doi.org/10.1016/S0003-2670(01)95909-4
  35. Sanchez-Moreno, R. A.; Gismera, M. J.; Teresa Sevilla, M.; Procopio, J. R. Sens. & Actuators B 2010, 143, 716. https://doi.org/10.1016/j.snb.2009.10.022
  36. Bakker, E.; Buhlmann, P.; Pretsch, E. Chem. Rev. 1997, 97, 3083. https://doi.org/10.1021/cr940394a

Cited by

  1. Interaction with a BN Nano-Cage vol.33, pp.10, 2012, https://doi.org/10.5012/bkcs.2012.33.10.3338
  2. Preparation of a solid-state ion-selective electrode based on polypyrrole conducting polymer for magnesium ion vol.11, pp.2, 2014, https://doi.org/10.1007/s13738-013-0317-2
  3. Construction of a new solid-state U(VI) ion-selective electrode based on polypyrrole conducting polymer vol.299, pp.3, 2014, https://doi.org/10.1007/s10967-013-2836-9
  4. Disposable gold nanoparticle functionalized and bare screen-printed electrodes for potentiometric determination of trazodone hydrochloride in pure form and pharmaceutical preparations vol.8, pp.21, 2018, https://doi.org/10.1039/C8RA00745D
  5. Comparison between Modified and Unmodified Carbon Paste Electrodes for Hexavalent Chromium Determination vol.30, pp.11, 2018, https://doi.org/10.1002/elan.201800505
  6. Optimization of Highly Sensitive Screen Printed Electrode Modified With Cerium (IV) Oxide Nanoparticles for Electrochemical Determination of Oxymetazoline Hydrochloride Using Response Surface Methodol vol.167, pp.4, 2012, https://doi.org/10.1149/1945-7111/ab7180
  7. Prototyping of a highly sensitive and selective chemisresistive sensor based on pencil graphite for the rapid detection of NO2 and NH3 vol.45, pp.5, 2012, https://doi.org/10.1039/d0nj05594h