DOI QR코드

DOI QR Code

Effect of the amount of battery charge on tube voltage in different hand-held dental x-ray systems

  • Kim, Eun-Kyung (Department of Oral and Maxillofacial Radiology, Dankook University College of Dentistry)
  • Received : 2011.09.27
  • Accepted : 2011.11.20
  • Published : 2012.03.31

Abstract

Purpose : Hand-held dental x-ray system is a self contained x-ray machine designed to perform intraoral radiography with one or two hands. The issue about its usage as general dental radiography is still in dispute. The aim of the present study was to assess the relationship between the amount of battery charge and the tube voltage in different handheld dental x-ray systems. Materials and Methods : Seven hand-held dental x-ray units were used for the study. Tube voltage was measured with Unfors ThinX RAD (Unfors Instruments AB, Billdal, Sweden) for 3 consecutive exposures at the different amount of battery charge of each unit. The average and the deviation percentage of measured kV from indicated kV of each unit were calculated. Results : Tube voltage of only 1 unit was 70 kV (indicated by manufacturer) and those of the others were 60 kV. Tube voltage deviation percentage from the indicated kV at the fully charged battery was from 2.5% to -5.5% and from -0.8% to -10.0% at the lowest charged battery. Conclusion : Tube voltages of all units decreased as the residual amount of the battery charge decreased. It is suggested that the performance test for hand-held x-ray system should be performed for the minimum residual charged battery as well as the full charged one. Persistent battery charging is suggested to maintain the proper tube voltage of the hand-held portable x-ray system.

Keywords

References

  1. CRCPD [Internet]. Suggested state regulations for control of radiations. Volume I. Part F. Diagnostic x-rays and imaging systems in the healing arts. [cited 2011 Aug 30]. Available from: http://www.crcpd.org/ssrcr.aspx.
  2. Van Dis ML, Miles DA, Parks ET, Razmus TF. Information yield from a hand-held dental x-ray unit. Oral Surg Oral Med Oral Pathol 1993; 76 : 381-5. https://doi.org/10.1016/0030-4220(93)90272-6
  3. FDA Center for Devices and Radiological Health [Internet]. Radiation safety considerations for x-ray equipment designed for hand-held use [cited 2011 Aug 30]. Available from: http:// www.fda.gov/MedicalDevices/DeviceRegulationandGuidance/ GuidanceDocuments/ucm094345.htm.
  4. CRCPD [Internet]. Q.A. Collectible: hand-held dental x-ray units. [cited 2011 Aug 30]. Available from: http://www.crcpd. org/Pubs/QAs.aspx.
  5. Ohio Department of Health [Internet]. 3701:1-66-06 Dental radiation-generating equipment. [updated 2009 Apr 15; cited 2011 Aug 30]. Available from: http://www.odh.ohio.gov/ ASSETS/BE4ED49EB661492CA41902FCAA455F5A/Fr66_06.PDF.
  6. Oregon Public Health Division [Internet]. Oregon administrative rules: x-rays in the healing arts. [cited 2011 Aug 30]. Available from: http://public.health.oregon.gov/HealthyEnvi ronments/RadiationProtection/Documents/Rules/2011/106_pr oposed.pdf.
  7. Washington State Legislature [Internet]. Hand-held x-ray system. Chapter 246-225A WAC. Radiation safety and diagnostic image quality standards for dental facilities. [updated 2011 Sep 7; cited 2011 Nov 30]. Available from: http://apps.leg.wa.gov/ WAC/default.aspx?cite=246-225A&full=true#246-225A-085.
  8. Korean Food and Drug Administration [Internet]. Electromedical equipment standards. Diagnostic x-ray equipments; 2011 - [cited 2011 Aug 30]. Available from: http://www.kfda. go.kr/medicaldevice/index.do?nMenuCode=22.
  9. Korean Food and Drug Administration [Internet]. Regulation for the safety management of diagnostic x-ray equipments; 1995 - [cited 2011 Aug 30]. Available from: http://likms.assembly. go.kr/law/jsp/law/Main.jsp.
  10. Goren AD, Bonvento M, Biernacki J, Colosi DC. Radiation exposure with the NOMAD portable X-ray system. Dentomaxillofac Radiol 2008; 37 : 109-12. https://doi.org/10.1259/dmfr/33303181

Cited by

  1. 이동형 구내방사선촬영기와 벽걸이 구내방사선촬영기로 촬영한 치근단 방사선촬영에서 환자의 흡수선량과 유효선량 평가 vol.50, pp.3, 2012, https://doi.org/10.4047/jkap.2012.50.3.184
  2. A Three-Dimensional Reconstructive Study of Pelvic Cavity in the New Zealand Rabbit ( Oryctolagus cuniculus ) vol.2014, pp.None, 2014, https://doi.org/10.1155/2014/489854
  3. Justification and good practice in using handheld portable dental X-ray equipment: a position paper prepared by the European Academy of DentoMaxilloFacial Radiology (EADMFR) vol.44, pp.6, 2015, https://doi.org/10.1259/dmfr.20140343
  4. The effects of device position on the operator's radiation dose when using a handheld portable X-ray device vol.45, pp.3, 2012, https://doi.org/10.1259/dmfr.20150245
  5. On the Safe Use of Portable Intraoral X-ray Units in Large-Scale Disasters vol.30, pp.3, 2012, https://doi.org/10.15214/jsodom.30.311
  6. Efficacy of Shields Against the Backscatter Radiation of Portable X-ray Units vol.17, pp.None, 2012, https://doi.org/10.12950/rsm.171016
  7. Assessment of image quality and exposure parameters of an intraoral portable X-rays device vol.48, pp.3, 2012, https://doi.org/10.1259/dmfr.20180329
  8. Precision of aiming with a portable X-ray device (Nomad Pro 2) compared to a wall-mounted device in intraoral radiography vol.48, pp.5, 2012, https://doi.org/10.1259/dmfr.20180221
  9. Evaluation of radiation exposure to operators of portable hand-held dental X-ray units vol.44, pp.2, 2012, https://doi.org/10.1007/s13246-021-00985-5