DOI QR코드

DOI QR Code

A Study on the Sanitary Condition of Kitchens in Food Court/Cafeterias - An Observation on Seasonal Variations

휴게음식점 주방의 환경위생상태에 관한 조사연구 - 계절별 변화를 중심으로 -

  • Kim, Jong-Gyu (Department of Public Health, Keimyung University) ;
  • Park, Jeong-Yeong (Department of Public Health, Keimyung University) ;
  • Kim, Joong-Soon (Department of Industrial and Management Engineering, Keimyung University)
  • 김종규 (계명대학교 공중보건학과) ;
  • 박정영 (계명대학교 공중보건학과) ;
  • 김중순 (계명대학교 경영공학과)
  • Received : 2012.02.01
  • Accepted : 2012.04.20
  • Published : 2012.04.30

Abstract

Objectives: This study was undertaken to assess the sanitary conditions in the kitchens of food court/cafeterias and determine seasonal variations. Methods: We measured environmental factors (air temperature, relative humidity, illumination intensity, noise level), and dropping airborne microbes (bacteria and fungi) in the kitchens of eight food court/cafeterias in four seasons (January, April, July, and October). Air temperature and relative humidity were measured with in/out thermo-hygrometers at 1.2-1.5 m above floor level. Illuminance measurement was performed through the multiple point method of Korean Standards (KS). Noise level was measured by the standard methods for the examination of environmental pollution (noise and vibration) of Korea. The estimation of dropping airborne bacteria and fungi was performed through use of Koch's method. Results: The highest kitchen air temperature was in July, and the lowest in January. The average temperature surpassed $21^{\circ}C$ throughout the seasons, suggesting a higher temperature than required for the safe handling of food. Humidity in all the kitchens was measured in the range of 50-60%. Half of the kitchens showed illumination intensities below 300 Lux in April. It was found that the sound pressure level of noise in almost all of the kitchens was higher than 85 dB (A). The highest levels of dropping airborne bacteria and fungi were noted in July. The numbers of airborne bacteria were higher than those of fungi. The levels of dropping airborne bacteria and fungi were affected by air temperature, relative humidity, season, and place. Conclusions: This study indicates that the kitchen environments were unqualified to supply safe food. The hygiene level of the kitchens should be improved.

Keywords

References

  1. Beumer RR, Kusumaningrum H. Kitchen hygiene in daily life. Int Biodeter Biodegr. 2003; 51: 299- 302. https://doi.org/10.1016/S0964-8305(03)00041-6
  2. Roberts D. Factors contributing to outbreaks of food poisoning in England and Wales 1970-1979. J Hyg Camb. 1982; 89: 491-498. https://doi.org/10.1017/S0022172400071059
  3. Ryan MJ, Wall PG, Gilbert RJ, Griffin M, Rowe B. Risk factors for outbreaks of infectious intestinal disease linked to domestic catering. Commun Dis Rep CDR Rev. 1996; 6: R179-183.
  4. Beumer RR, te Giffel MC, Spoorenberg E, Rombouts FM. Listeria species in domestic environments. Epidemiol Infect. 1996; 117: 437-442. https://doi.org/10.1017/S0950268800059094
  5. bouts FM. Listeria species in domestic environments. Epidemiol Infect. 1996; 117: 437-442. https://doi.org/10.1017/S0950268800059094
  6. Kass H, Harrigton B, Bisesi M., Khuder S. Comparison of microbiological evaluations of selected kitchen areas with visual inspections for preventing potential risk of foodborne outbreaks in food service operations. J Food Prot. 2001; 64: 509-513.
  7. Korea Food and Drug Administration. Hi-safer food. Daegu: KFDA Daegu branch, 2009b.
  8. Kim JG. A survey on the sanitary condition of kitchens in school food-service programs. Kor J Environ Health. 2003; 29: 87-93.
  9. Kim JG, Lee KM. A study on the sanitary condition of kitchens and facilities of school food-service programs in elementary schools - Part 2. Temperature, humidity, noise and microbiological examination. J Kor Publ Health Assoc. 2003; 29: 259-268.
  10. Seo SH, Moon SJ, Choi JH. Evaluation of hygienic status using ATP bioluminescence assay and food service workers' sanitation performance in elderly welfare facilities. J Kor Diet Assoc. 2011; 17: 142- 160.
  11. Joo KT, Choi AS. Measurement and computing method of the average illuminance in residential Areas. J Kor Inst Illum Electr Install Eng. 2006; 20: 1-8.
  12. Korean Standards Association. Measurement method of the illuminance. Seoul: KSA, 1987.
  13. Ministry of Environment of Korea. Standard methods for the examination of environmental pollution - Noise and Vibration. Seoul: MEK, 2008.
  14. Choi HY, Park SG, Kihl CN. Laboratory methods for environmental health. Seoul: Shinkwang Publishing Co., 1993.
  15. Marriott NG. Essentials of food sanitation. New York: Chapman & Hall, 1997.
  16. McSwane D, Rue N, Linton R. Essentials of food safety and sanitation, 3rd ed., Upper Saddle River: Prentice Hall, 2003.
  17. Shin GH. Comparison of school food service's hygiene states by actual management system. M. P. H. Thesis, Seoul National University, 2001.
  18. Sprenger RA. Hygiene for management. Doncaster: Highfield Publications, 2005.
  19. Hunt DRG, Gidman MI. A national field survey of house temperatures. Build Env. 1982; 17: 107-124. https://doi.org/10.1016/0360-1323(82)90048-8
  20. Yohanis YG, Mondola JD. Annual variations of temperature in a sample of UK dwellings. Appl Energy. 2010; 87: 681-690. https://doi.org/10.1016/j.apenergy.2009.08.003
  21. Korea Food and Drug Administration. Manual of Sanitary Management in Food Service Institutions. Seoul: KFDA, 2009a.
  22. Korean Standards Association. Korean industrial standard - Illuminance. Seoul: KSA, 2006.
  23. Kim JG. Food hygiene and sanitation. Seoul: Shinkwang Publishing Co., 2006.
  24. Korea Ministry of Government Legislation: Occupational Safety and Health Act. Seoul: KMGL, 2010.
  25. Sound & Noise. Available from: http://blog.daum.net/ _blog/BlogTypeView.do?blogid=0AN5b&articleno= 8669933#ajax_history_home [accessed November 10, 2010].
  26. American Conference of Governmental Industrial Hygienists. The ACGIH TLVs and BEIs. Cincinnati: ACGIH, 2002.
  27. Jeon JY, You J. Chang HY. Sound radiation and sound quality characteristics of refrigerator noise in real living environments. App Acoust. 2007; 68: 1118-1134. https://doi.org/10.1016/j.apacoust.2006.06.005
  28. Kim, JG, Park JY. A survey on the sanitary condition of indoor environment of academic buildings and cafeteria in university campus. J Nakdong-River Env Res Inst. 2010; 14: 47-57.
  29. Li CS, Kuo YM. Microbiological indoor air quality in subtropical areas. Env Int. 1993; 19: 233-239. https://doi.org/10.1016/0160-4120(93)90084-U
  30. Nasir ZA, Colbeck I. Assessment of bacterial and fungal aersols in different residential settings. Water Air Soil Pollut. 2010; 211: 367-377. https://doi.org/10.1007/s11270-009-0306-3
  31. Rajasekar A. Balasubramanian R. Assessment of airborne bacteria and fungi in food courts. Build Env. 2011; 46: 2081-2087. https://doi.org/10.1016/j.buildenv.2011.04.021
  32. See SW, Balasubramanian R. Characterization of fine particle emissions from incense burning. Build Env. 2011; 46: 1074-1080. https://doi.org/10.1016/j.buildenv.2010.11.006
  33. Aydogdu H, Asan A, Otkun MT, Ture M. Monitoring of fungi and bacteria in the indoor air of primary schools in Edirnecity, Turkey. Indoor and Built Environment 2005; 14: 411-425. https://doi.org/10.1177/1420326X05057539