DOI QR코드

DOI QR Code

A Study on the Formaldehyde Concentration Producing Characteristics and Reducing Method in Newly Built Apartment House

신축 공동주택의 포름알데히드 농도 발생특성과 저감대책에 관한 연구

  • 함진식 (대구대학교 건축공학과)
  • Received : 2012.05.10
  • Published : 2012.09.25

Abstract

This study intends to find out characteristic of the generation of formaldehyde concentration produced in livingroom and rooms, first, with closed windows, second, with air cleaner operation, photo-catalyst installation, and opened openings in newly constructed apartment house. As a result, the level of formaldehyde concentration was higher than that of Korean Environmental Standard under closed windows case. And, it may be harmful for health by repeating to stay under closed windows. Therefore the solution is required to reduce its concentration. By operating air cleaner with VOCs filter, compared to non-operation, there was about 18% reduction effect of the formaldehyde concentration after 24 hours, though there was no reduction effect of it till 8 hours from starting to measure. Compared to closed windows, there was reduction effect of the formaldehyde concentration in half when photo-catalyst is installed on ceilings, walls, floors, door frames, and doors, etc in main room and room 2. Each room under closed windows had ventilation in every hour. There was huge deviation for the ventilation frequency based on room size and its frequency was getting increased when the opening areas are getting bigger. The level of the formaldehyde concentration in livingroom and main room was below that of Korean Environmental Standard even whole opening by side. However, regardless of opening windows area, room 1 and 2 which have relatively larger areas of windows than their volume can keep it below 0.1PPM, Korean Environmental Standard. In summary, the ventilation by opening windows in each room was the most noticeable effect to reduce the level of formaldehyde concentration based on evaluation of various cases including air cleaner operation, and photo-catalyst installation.

Keywords

References

  1. 김신도, 서병량, 바닥재료에서 발생되는 VOCs와 Formaldehyde 의 방출특성 및 방출강도 평가, 대한건축학회 추계학술발표대 회논문집, 2002
  2. 이윤규, 한길원, 공동주택의 포름알데히드 농도 특성분석에 관한 연구, 대한건축학회논문집 계획계, 2003. 10
  3. 박진철, 주거건축물의 실내공기환경 개선에 관한 연구, 대한건축학회논문집 계획계, 2003. 6
  4. 유형규, 박진철, 이언구, 신축공동주택에서의 실내공기 오염물질 방출 저감 프로세스에 관한 연구, 설비공학논문집 제17권 제5호, 2005
  5. 이윤정, 임남웅, 임한진, 선주남, 김태년, TiO2로 코팅된 벽지와 한지를 이용한 포름알데히드 분해, 대한환경공학회지 Vol 24, No 6, 2002
  6. 유형규, 박진철, 이언구, 실내건축자재 폼알데하이드 및 휘발성유기화합물 방출 특성에 관한 연구, 대한건축학회논문집 계획계, 2005. 7
  7. 사단법인 한국대기환경학회, 실내 공기질 정책 및 관측기술, 2004
  8. 이윤하, 새집증후군, RPUB, 2004
  9. 함진식, 초고층 공동주택에서의 환기량 실측에 관한 연구, 대한건축학회논문집 계획계 15권 3호, 1999. 3
  10. 日本規格協會, 屋內換氣量測定方法, (炭酸ガス法) JISA 1406, 1974
  11. 함진식, レ-サ-ガス法による換氣量算定精度に關する硏究, 오시카대학대학원 박사학위논문, 1988