Abstract
Miller cycle is considered as an effective means to meet the regulation on Tier II and to reduce $CO_2$ emission. For this cycle, the amount of intake air supplied should be enough increased. Therefore, the intake system with minimized resistance for air flow is under consideration. In this study, the flow coefficients of intake valves were measured in order to obtain the basic data for the cycle simulation and intake port design. The flow coefficients were measured using the steady-flow test rig. As a test result for the poppet valve used the marine engine with medium speed, the flow coefficients are increased to about 0.62 with the valve lift. In addition it is confirmed that the flow coefficients have the characteristic value irrelevant to the S/B ratio.
밀러 사이클은 저배기 및 고효율 달성으로 Tier II 규제뿐만 아니라 $CO_2$ 저감을 동시에 달성할 수 있는 기술로 알려져 있다. 그러나 이를 위해서는 충분한 흡입공기량이 확보되어야 하며 흡기계통은 공기저항을 최소화할 수 있는 형상으로 개선되어야 한다. 본 연구에서 흡기계통 설계 및 사이클 해석에 활용하기 위한 기초 자료 확보를 위해 흡기밸브의 유량계수를 측정하였다. 유량계수 측정에는 정상유동장치를 이용하였다. 중속 박용기관에 사용되는 포핏 밸브를 대상으로 실험을 수행한 결과, 흡기밸브 유량계수는 밸브양정의 증가에 따라 약 0.62까지 지속적으로 증가하는 경향이며 행정/보어 비와는 무관한 흡기밸브 고유의 특성이 있음을 확인하였다.