Abstract

This study aims to investigate advantages of complex installation of green roof and PV system in a public building, to analyze the impact of green roof on the efficiency of PV power generation, and to consider the correlation between green roof and PV power generation. When the temperature and power generation of the modules installed in the green roof and non-green roof of the public building were measured for 3 days, the average temperature of the green roof was 23.6 degrees, and it was 36.1 degrees in the non-green roof which increased by nearly 53%. Overall, the module temperature in the green roof was lower. On the other hand, in relation to the PV generation depending on temperature reduction during the same period, the mono-crystalline module and the poly-crystalline module in the green roof showed an increase in generation at nearly 222.2W and 341.6W, and the efficiency rose by 5.5% and 6.2%, respectively, compared to the modules in the non-green roof. Therefore, it is analyzed that green roof has a positive influence on PV power generation. Finally shows the efficiency of the installed on the Green Roof PV system (complex Installation) higher than on the concrete roof PV system. Thus, the complex PV systems as well as the usual benefits of green roofs will provide greater synergies.

Keywords

References

  1. Lee, Doo-Ho and 1 accompanying person, A Consideration on the Surface Temperature Reducing Effect of Green Roof System Flat Roof, Journal of the Korea Institute of Ecological Architecture and Environment, Vol. 12, No. 3, 2012. 06
  2. Park, Seon-Yeong and 4 accompanying person, Effect of Green Roof to Reduce the Electrical Fire, Korean Society of Hazard Mitigation, Vol. 12, No. 8, 2012. 08
  3. Kim, Dae-Wuk and 2 accompanying person, Simulation of Changes in Nearby Thermal Environment According Green Roof in Low-Rise Residental Area of Daegu, Journal of the Korean Housing Association, Vol. 24, No. 3, 2013. 06
  4. Lee, Chun-Woo and 2 accompanying person, A Study on the Analysis of Temperature Reduction Effect by the Type of the Green Roof, Journal of the Korean Housing Association, Vol. 22, No. 3, 2011. 06
  5. Choi, Dong-Ho and 1 accompanying person, An Experimental Study of Surface Materials for Planting of Building Surface by the Radiant Heat Balance Analysis in the Summer, Journal of the Korean Solar Energy Society, Vol. 30, No. 3, 2010. 06
  6. Kim, Dae-Hyun and 1 accompanying person, Improving the power of PV module by a surface cooling system, Journal of the Korean Solar Energy Society, Vol. 29, No. 6, 2009. 12
  7. Kim, Youn-Sik, A Study on Efficiency Improvement of Solar cell Temperature Dependence, Technology of Future Energy, 2009. 12
  8. Ahn, Tae-Kyung, Evaluation for Thermal Performance of Apartment House Top Floor using Roof Planting, The Society of Living Environment System, 10(3), 2003
  9. Park, Chan-Pil, Study on Improvement of Thermal Environment by Green Roof Systems on RC Building, The Korea Society of Environmental Restoration Technology, 7(1), 2004
  10. Lee Dong-Kun, The Effect of Temperature Reduction as Influenced by Rooftop Greening, The Korea Society of Environmental Restoration Technology, 8(6), 2005
  11. Oh, Seung-Hwan, The Analysis of Temperature Reduction Effect of an Extensive Greenroof, Seoul National Univ., 2006
  12. Kim Ju-Hwan, A Study on the Evaluation of Energy Performance due to the Application of Greenery Cover Method in Education Buildings, Yeungnam Univ., Graduate School, 2009
  13. Kim, Ji-Su, A study on the change of PV efficiency by the reduction effects in temperature of green roof, Semyung Univ., Graduate School, 2011
  14. Sam C. M. and 1 accompanying person, Integration of green roof and photovoltaic systems, Paper submitted to Joint Symposium 2011: Integrated Building Design in the New Era of Substantiality, 2011. 11
  15. Bruce Dvorak and 1 accompanying person, Rooftop Temperature reduction from unirrigated modular green roofs in south-central Texas, Urban Forestry & Urban Greening, Avaliable online 7 July 2012
  16. Kohler M. and 2 accompanying person, Interaction between PV- systems and extensive green roofs, In Proceedings of the Fifth Annual Greening Rooftops for Sustainable Communities Conference, Awards and Trade Show, Minneapolis, April 29-May 1, 2007
  17. Deo Parasad and 1 accompanying person, Designing with Solar Power: A Source Book for BIPV, Images Publishing, 2005