DOI QR코드

DOI QR Code

Automated Analysis Technique Developed for Detection of ODSCC on the Tubes of OPR1000 Steam Generator

  • Received : 2013.11.29
  • Accepted : 2013.12.23
  • Published : 2013.12.30

Abstract

A steam generator (SG) tube is an important component of a nuclear power plant (NPP). It works as a pressure boundary between the primary and secondary systems. The integrity of a SG tube can be assessed by an eddy current test every outage. The eddy current technique(adopting a bobbin probe) is currently the main technique used to assess the integrity of the tubing of a steam generator. An eddy current signal analyst for steam generator tubes continuously analyzes data over a given period of time. However, there are possibilities that the analyst conducting the test may get tired and cause mistakes, such as: missing indications or not being able to separate a true defect signal from one that is more complicated. This error could lead to confusion and an improper interpretation of the signal analysis. In order to avoid these possibilities, many countries of opted for automated analyses. Axial ODSCC (outside diameter stress corrosion cracking) defects on the tubes of OPR1000 steam generators have been found on the tube that are in contract with tube support plates. In this study, automated analysis software called CDS (computer data screening) made by Zetec was used. This paper will discuss the results of introducing an automated analysis system for an axial ODSCC on the tubes of an OPR1000 steam generator.

Keywords

References

  1. Zetec Inc., "Computer Data Screening User Guide," USA (2001)
  2. Electric Power Research Institute, "Automated analysis performance demonstration database pressurized water reactor steam generator examination guidelines," EPRI SGMP TR-10119123, USA, pp. 6-8 (2009)
  3. Electric Power Research Institute, "Pressurized water reactor steam generator examination guidelines: Revision 7," EPRI SGMP TR-1013706, USA, pp. G-7 (2007)
  4. Electric Power Research Institute, "Steam generator tubing burst testing and leak rate testing guidelines, EPRI Binned POD_ alculator" EPRI SGMP TR-1006783, USA, pp. 6-8 (2002)
  5. Korea Hydro & Nuclear Power Co., LTD, "Integrated guidelines of steam generator management program: Revision 1," Standard Procedure SG Inspection, Korea, p. 28 (2012)