DOI QR코드

DOI QR Code

Evaluation of Air Quality with and without Vapor Recovery Systems of Stage II

주유소 Stage II의 유증기회수설비 가동에 따른 대기질 평가

  • Kim, Jae Hyuck (Department of Environmental Engineering, Kwangwoon University) ;
  • Jung, Seok Hyeon (Hazardous Air Pollutants Management Team, Korea Environment Corporation) ;
  • Kim, Hyung-Seok (Hazardous Air Pollutants Management Team, Korea Environment Corporation) ;
  • Jang, Tae-Hyuk (Hazardous Air Pollutants Management Team, Korea Environment Corporation) ;
  • Yoo, Kyung Seun (Department of Environmental Engineering, Kwangwoon University)
  • 김재혁 (광운대학교 환경공학과) ;
  • 정석현 (한국환경공단 대기환경처 유해대기관리팀) ;
  • 김형석 (한국환경공단 대기환경처 유해대기관리팀) ;
  • 장태혁 (한국환경공단 대기환경처 유해대기관리팀) ;
  • 유경선 (광운대학교 환경공학과)
  • Received : 2013.08.01
  • Accepted : 2013.08.28
  • Published : 2013.12.31

Abstract

A field study was conducted to evaluate air quality from gas stations with and without Stage II vapor recovery systems that are currently used to reduce VOCs. The THC and VOCs levels were monitored for the test at three locations (inside office, around refueling area, site boundary) from a total of five gas stations. The results showed a considerable reduction in THC concentration which ranged from 48.7% to 81.8% with and without the operation of the Stage II VRS. Acoording to our comparative analysis, BTEX and other 19 VOCs levels were also significantly reduced with Stage II vapor recovery systems.

Keywords

References

  1. Berglund, P.M. and G. Petersson (1990) Hazardous petrol hydrocarbonds from refuelling with and without vapor recovery, Sci. Total. Environ., 91, 49-57. https://doi.org/10.1016/0048-9697(90)90287-5
  2. Capleton, A.C. and L.S. Levy (2005) An overview of occupational benzene exposures and occupational exposure limits in Europe and North America, Chem. Biol. Interace., 153-154, 43-53. https://doi.org/10.1016/j.cbi.2005.03.007
  3. Carrieri, M., E. Bonfiglio, M.L. Scapellato, I. Macca, G. Tranfo, P. Faranda, E. Paci, and G.B. Bartolucci (2006) Comparision of ecposure assessment methods in occupational exposure to benzene in gasoline filling-station attendants, Toxicol. Lett., 162, 146-152. https://doi.org/10.1016/j.toxlet.2005.09.036
  4. Cruz-Nunez, X., J.M. Hernandez-Solis, and L.G. Ruiz-Suarez (2003) Evaluation of vapor recovery systems efficiency and personal exposure in service stations in Mexico City, Sci. Total. Environ., 309, 59-68. https://doi.org/10.1016/S0048-9697(03)00048-2
  5. Delfino, R.J., H. Gong, W.S. Linn, E.D. Pellizzari, and Y. Hu (2003) Asthma symptoms in Hispanic children and daily ambient exposures to toxic and criteria air pollutants, Environ. Health. Perspect., 111, 647-656.
  6. Derwent, R.G., M.E. Jenkin, N.R. Passant, and M.J. Pilling (2007) Reactivity-based strategies for photochemical ozone control in Europe, Env. Sci. Pol., 10, 445-453. https://doi.org/10.1016/j.envsci.2007.01.005
  7. Isabel, M., T. Morales, D.M. Marta, G.F. Enrique, B.C. Antonia, and B.R. Jonathan (2010) Assessing the impact of petrol stations on their immediate surroundings, J. Env. Manage., 91, 2754-2762. https://doi.org/10.1016/j.jenvman.2010.08.009
  8. Jung, C.H., D.Y. Park, L.H. Lee, S.J. Kim, and J.G. Kang (2008) A development of the recovery system by condensation process for the gas station, Proceeding of the 47th meeting of KOSAE (2008), 464-465.
  9. Karakitsios, S.P., V.K. Delis, P.A. Kassomenos, and G.A. Pilidis (2007) Contribution to ambient benzene concentrations in the vicinity of petrol stations, Estimation of the Associated Health Risk, 41, 1889-1902.
  10. KECO (Korea Environment Corporation) (2011) Research report on ways to expand a vapor recovery systems of Stage II of gas stations.
  11. Kim, J.H., G.K. Hong, and T.H. Jang (2012) The characteristics and management of VOCs emitted from gasoline reservoir at gas station, Proceeding of the 54th meeting of KOSAE (2012), 104-104.
  12. Kim, J.H., Y.L. Sohn, H.S. Kim, T.H. Jang, and K.S. Yoo (2013) A study on present conditions and improvement alternatives of vapor recovery unit of StageII at gas stations, J. of Env. Pol. Admin., 21, 115-140. (in Korean with English abstract) https://doi.org/10.1007/s10924-012-0465-y
  13. Kim, K.S., S.G. Bae, S.L. Yoon, O.S. Lee, U.Y. Sun, and J.H. Hong (2003) An experimental study on the emission characteristics of VOCs generation from automotive fuel tank at gasoline reservoir, Proceeding of the 35th meeting of KOSAE (2003), 91-92.
  14. NIER (Nitional Insititute of Environmental Research) (2010) Method of gas station vapor recovery systems of Stage II.
  15. Rekhadevi, P.V., M.F. Rahman, M. Mahboob, and P. Groyer (2010) Genotoxicity in filling station attendants exposed to petroleum hydrocarbons, Ann. Occup. Hyg., 54(8), 944-954. https://doi.org/10.1093/annhyg/meq065
  16. Romieu, I., M. Ramirez, F. Meneses, D. Ashley, S. Leinire, and K. Fung (1999) Environmental exposure to volatile organic compounds among workers in Mexico City as assessed by personal monitors and blood concentrations, Environ. Health. Perspect., 107, 511-515. https://doi.org/10.1289/ehp.99107511
  17. Steinemann, A.C. (2008) Fragranced consumer products and undisclosed ingredients, Environ. Impact. Asses., 29, 32-38.
  18. US EPA (1999) Compendium of Methods for the Determination of Toxic Organic Compounds in Ambient Air, Method TO-17, Center for Environmental Research Information, moffice of Research and Development.
  19. US EPA (2009) National-Scale Air Toxics Assessment (NATA), http://www.epa.gov/nata2002/ (accessed 10.05.13).
  20. Wichmann, F.A., A. Muller, L.E. Busi, N. Cianni, L. Massolo, U. Schlink, A. Porta, and P.D. Sly (2009) Increased asthma and respiratory symptoms in children exposed to petrochemical pollution, J. Allergy. Clin. Immunol., 123, 632-638. https://doi.org/10.1016/j.jaci.2008.09.052

Cited by

  1. MACT Application Effect in Petrochemical Industry to Minimize Benzene Fugitive Emission vol.38, pp.8, 2016, https://doi.org/10.4491/KSEE.2016.38.8.435