DOI QR코드

DOI QR Code

Study on Performance Characteristics of Spiral Fin-Tube Evaporator Applied to Domestic Refrigerator-Freezers

나선형 핀-튜브 증발기를 적용한 냉장고의 성능 특성에 관한 연구

  • Received : 2011.10.20
  • Accepted : 2012.11.23
  • Published : 2013.03.01

Abstract

The objective of this study was to investigate the feasibility of replacing a conventional plate fin-tube evaporator with a spiral fin-tube evaporator by comparing the performance of domestic refrigerator-freezers adopting either the plate fin-tube evaporator or spiral fin-tube evaporator. Experiments were conducted for the domestic refrigerator-freezers using either a 2-column and 15-row plate fin-tube evaporator or three spiral fin-tube evaporators with 11, 13, and 15 tube rows (N). The optimum refrigerant charge decreased with a decrease in the number of tube rows. The power consumptions of the domestic refrigerator-freezers using the spiral fin-tube evaporators with N = 11 and 13 were 2.8% and 1.5% lower than those using the plate fin-tube evaporator, respectively. In addition, the cooling capacity of the spiral fin-tube evaporator with N = 13 was 3%-7% higher than that of the plate fin-tube evaporator under the frosting condition. In a cooling speed test, all of the evaporators showed similar performances.

본 연구는 평판 핀-튜브 증발기와 나선형 핀-튜브 증발기를 적용한 가정용 냉장고의 성능특성 비교를 통하여 기존에 사용하고 있는 핀-튜브 증발기를 나선형 핀-튜브 증발기로 대체할 수 있는 가능성을 고찰하는데 그 목적이 있다. 실험은 2단 15열의 평판 핀-튜브 증발기와 2단 15열에서 2단 11열까지 열 수를 단계적으로 감소시킨 3종류의 나선형 핀-튜브 증발기를 실제 냉장고에 적용하여 수행하였다. 핀-튜브 증발기의 열 수가 감소할수록 냉동시스템의 최적 냉매 충전량은 감소하였으며, 2단 13열과 2단 11열의 나선형 핀-튜브 증발기를 장착한 냉장고의 소비전력은 기존 2단 15열의 평판 핀-튜브 증발기를 적용한 냉장고 대비 각각 1.5%와 2.8% 감소하였다. 또한 내착상 실험결과 나선형 핀-튜브 증발기가 기존 평판 핀-튜브 증발기와 비교하여 같은 착상조건에서 3~7% 향상된 냉각능력을 보였다. 냉각속도 실험에서는 모든 증발기는 동등수준의 성능을 나타내었다.

Keywords

References

  1. Lee, M., Lee, D. and Kim, Y., 2008, "Performance Characteristics of a Small-Capacity Directly Cooled Refrigerator Using R290/R600a (55/45)," Int. J. of Refrigeration, Vol. 31, pp. 734-741. https://doi.org/10.1016/j.ijrefrig.2007.11.014
  2. Yun, R., Kim, Y. and Kim, Y., 2009, "Air Side Heat Transfer Characteristics of Plate Finned Tube Heat Exchangers with Slit Fin Configuration Under Wet Conditions," Applied Thermal Engineering, Vol. 29, pp. 3014-3020. https://doi.org/10.1016/j.applthermaleng.2009.03.017
  3. Jung, H. W., Yoon, W. J., Chung, H. J. and Kim, Y. C., 2010, "Performance Characteristics of a Bypass Two-Circuit Refrigeration Cycle Designed for Refrigerators," Int. J. of Air-Conditioning and Refrigeration, Vol. 18, No. 2, pp. 141-147. https://doi.org/10.1142/S2010132510000241
  4. Lee, M., Kim, Y., Lee, H. and Kim, Y., 2010a, "Air- Side Heat Transfer Characteristics of Flat Plate Finned-Tube Heat Exchangers with Large Fin Pitches Under Frosting Conditions," Int. J. Heat Mass Transfer, Vol. 53, pp. 2655-2661. https://doi.org/10.1016/j.ijheatmasstransfer.2010.02.047
  5. Kang, T., Lee, M., Kim, Y. and Yun, S., 2010, "Experimental Study on the Air-Side Heat Transfer Characteristics of a Spirally-coiled Circular Fin-Tube Heat Exchanger with the Variation of Geometric Parameters," Trans. Korean Soc. Mech. Eng. B, Vol. 34, No. 5, pp. 515-522. https://doi.org/10.3795/KSME-B.2010.34.5.515
  6. ISO 15502:2005(E), 2005, Household Refrigerating Appliances - Characteristics and Test Methods, pp. 1-81.
  7. Bjork, E., Palm, B., 2006 "Refrigerant Mass Charge Distribution in a Domestic Refrigerator. Part I. Transient Conditions," Applied Thermal Engineering Vol. 26, pp. 829-837. https://doi.org/10.1016/j.applthermaleng.2005.10.003
  8. Rubas, P. J., Bullad, C. W, 1995, "Factors Contributing to Refrigerator Cycling Losses," Int. J. of Refrigeration, Vol. 18, No. 3, pp. 167-176.
  9. Lee, M., Lee S., Jung, H., Kim, Y. and Park, J. 2010c, "Frosting Heat Transfer Characteristics of Evaporators used for Household Refrigerators According to Fin Configuration," Trans. Korean Soc. Mech. Eng. B, Vol. 34, No. 12, pp. 1071-1078. https://doi.org/10.3795/KSME-B.2010.34.12.1071
  10. Yan, W. M., Li, H. Y., Wu, Y. J., Lin, J. Y. and Chang, W. R., 2003, "Performance of Finned Tube Heat Exchanger Under Frosting Condition," Int. J. Heat Mass Transfer, Vol. 46, pp. 871-877. https://doi.org/10.1016/S0017-9310(02)00346-0
  11. Tang, L.H., Zeng, M., Wang Q.W., 2009, "Experimental and Numerical Investigation on Air- Side Performance of Fin-and-Tube Heat Exchangers with Various Fin Patterns," Experimental Thermal and Fluid Science, Vol. 33, pp. 818-827. https://doi.org/10.1016/j.expthermflusci.2009.02.008