DOI QR코드

DOI QR Code

Hysteresis Behavior of Semirigid CFT Column-to-Beam Connections with a Double Web-Angle

더블 웨브앵글 반강접 CFT 기둥-보 접합부의 이력거동

  • Received : 2012.11.13
  • Accepted : 2013.02.04
  • Published : 2013.02.27

Abstract

This paper presents the results from a systematic finite element study on the bending moment resisting capacity of double web-angle connection for a CFT(concrete filled tube) composite frame subjected to cyclic loading. The three-dimensional nonlinear finite element models are constructed to investigate the rotational stiffness, bending moment capacity, and failure modes of the partially restrained composite CFT connections. A wide scope of additional structural behaviors explain the different influences of the double web-angle connections parameters, such as the different thickness of connection angles and the gage distances of high strength steel connection bar. The moment-rotation angle relationships obtained statically from the finite element analysis are compared with those from Richard's theoretical equation.

본 논문은 반복하중을 받는 CFT 합성골조의 더블 웨브앵글 접합부의 휨모멘트 내력에 대해 체계적으로 수행된 유한요소 연구로부터 얻은 결과를 제시하고 있다. 합성 부분강접 CFT 접합부의 회전강성, 휨모멘트 내력 및 파괴모드를 연구하기 위하여 3차원 비선형 유한요소 해석이 수행되었다. 부가적인 다양한 구조적 거동은 앵글의 두께 및 고강도 강봉 게이지 거리로 더블 웨브앵글 접합부의 파라미터에 대한 영향을 설명하고 있다. 해석모델의 적합성은 정적 유한요소해석 결과로부터 얻은 모멘트-회전각 곡선을 Richard의 회귀분석을 통하여 비교 분석하였다.

Keywords

References

  1. 양재근, 이수권, 김호근(2003) 보와 기둥이 더블앵글로 접합된 골조의 거동, 대한건축학회논문집 구조계, 대한건축학회, 제19권, 제6호, pp.61-68. Yang, J.G., Lee, S.K., and Kim, H.K. (2003) Behavior of frames with column flange boltedbeam web welded double angle connections, Journal of the Architectural Institute of Korea, Structure & Construction, Vol. 19, No. 6, pp.61-68.
  2. 양재근, 이길영(2006) 더블앵글 접합부의 초기강성 및 극한모멘트 산정을 위한 해석모델, 한국강구조학회논문집, 한국강구조학회, 제18권, 제3호, pp.311-320. Yang, J.G. and Lee, G.Y. (2006) Analytical models for the initial stiffness and ultimate moment of a double angle connection, Journal of the Korean Society of Steel Construction, Vol. 18, No. 3, pp. 311-320.
  3. McMullin, K.M. and Astaneh, A. (1988) Analytical and experimental studies of double-angle framing connections, Reprt no. UCB/SEMM-88/14, Department of Civil Engineering, University of California, Berkeley.
  4. Munse, W.H., Bell, W.G., and Chesson, E. (1959) Behavior of riveted and bolted beam-to-column connections, Struct. Div. ASCE, 85 ST3, pp.29-50.
  5. Owen, G.W. and Moore, D.B. (1992) The robustness of simple connections, Struct. Eng., 70, pp.37-46.
  6. Sommer, W.H. (1969) Behavior of welded header plate connections, M.S. thesis, University of Toronto, Canada.
  7. 신경재, 임보혁, 이수현, 최성모(2011) 볼트로 접합한 보-기둥 접합부의 유한요소해석, 한국강구조학회논문집, 한국강구조학회, 제23권, 제3호, pp.305-316. Shin, K.J., Lim, B.H., Lee, S.H., and Choi, S.M. (2011) FEA of beam-column connection with bolted web, Journal of the Korean Society of Steel Construction, Vol. 23, No. 3, pp.311-316.
  8. 김선희, 방중석, 박영욱, 최성모(2012) 합성반강접 CFT기둥-보 접합부 구조의 경제성평가, 한국강구조학회논문집, 한국강구조학회, 제24권, 제1호, pp.109-117. Kim, S.H., Bang, J.S., Park, Y.W., and Choi, S.M. (2012) The structural economical efficiency evaluation of partially restrained composite CFT column-tobeam connection, Journal of the Korean Society of Steel Construction, Vol. 24, No. 1, pp.109-117. https://doi.org/10.7781/kjoss.2012.24.1.109
  9. Lother, J.E. (1960) Advanced design in structural steel, Prentice-Hall, Englewood Cliffs, NJ.
  10. Frye, M.J. and Morris, G.A. (1975) Analysis of Flexibly Connected Steel Frame, Canadian Journal of Civil Engineering, Vol. 2, pp.280-291. https://doi.org/10.1139/l75-026
  11. ANSYS (2011) ANSYS multiphysics, Version 13.0, ANSYS Inc. Canonsburg, PA, USA.
  12. AISC (2006) Manual of steel construction, American Institute of steel Construction, American Institute of steel Construtions, 13th Edition, American Institute of steel Construction, Chicago.
  13. Richard, R.M. and Abbott, B.J. (1975) Versatile elastic-plastic stress-strain formula, Journal of Engineering Mechanics Division, ASCE, Vol. 101, pp.511-515.
  14. Richard, R.M., Hsia, W.K., and Chmielowiec, M. (1988) Derived moment-rotation curves for double-framing angles, Computer and Structures, Vol. 3, pp.485-494.
  15. Chen. W.F., and Lui, E.M. (1991) Stability Design of steel Frames, CRC Press.
  16. Abolmaali, A., Kureti, A.R., and Razavi, H. (2003) Hysteresis behavior of semi-rigid double web angle steel connections, Journal of Constructional Steel Research, Vol. 59, pp.1057-1082. https://doi.org/10.1016/S0143-974X(03)00005-1

Cited by

  1. Development and Performance Evaluation of ㅍ-Section Steel Column New Shape Weak-Axis Connection vol.14, pp.4, 2014, https://doi.org/10.9798/KOSHAM.2014.14.4.25
  2. Monotonic and Hysteresis Behavior of Semirigid CFT Column-to-Beam Connections with a Top-Seat Angle vol.26, pp.3, 2014, https://doi.org/10.7781/kjoss.2014.26.3.191
  3. CFT 합성골조의 내진성능을 위한 스마트 반강접합의 이력거동 vol.27, pp.1, 2013, https://doi.org/10.7781/kjoss.2015.27.1.099
  4. SMA 적용 상·하부 ㄱ형강 CFT 기둥-보 접합부의 내진성능 vol.29, pp.6, 2013, https://doi.org/10.7781/kjoss.2017.29.6.423
  5. Hysteresis Characteristics of Self-Centering Semirigid CFT Column-to-Beam Double Web-Angle Connections vol.31, pp.4, 2013, https://doi.org/10.7781/kjoss.2019.31.5.311