The Sterilization Effectiveness for Bacterial Contamination by Cleaning Methods in the Glasses for Vision Correction

시력교정용 안경의 세척 법에 따른 오염 균의 제균 효과

  • 백승선 (대전보건대학교 안경광학과) ;
  • 김현경 (대전보건대학교 안경광학과) ;
  • 이규병 (충청대학교 안경광학과) ;
  • 이현주 (대전보건대학교 안경광학과) ;
  • 김흥수 (대전보건대학교 안경광학과)
  • Received : 2013.05.07
  • Accepted : 2013.06.15
  • Published : 2013.06.30

Abstract

Purpose: This research was to evaluate the sterilization effectiveness for bacterial contamination by general cleaning method of glasses for vision correction. Methods: From 82 eyeglass wearers the number of bacteria before and after cleaning was counted to check the status of the eradication. Results: The results after ultrasonic cleaning by using the tap water did not showed change of bacterial species. Ultrasonic cleaning using the 70% rubbing alcohol showed cleaning of 46.2% of bacteria. Ultrasonic cleaning using the 70% rubbing alcohol after brushing with general detergent showed clearing of 85.7% of bacteria. Conclusions: When glasses were brushed with a detergent, opportunities infectious bacteria in glasses for vision correction were removed effectively. These results can be suggested as a guideline for management of clean glasses.

목적: 본 연구는 시력교정용 안경에서 범용 적으로 활용되고 있는 세척방법에 따른 오염 균의 제균 효과를 알아보고자 하였다. 방법: 실험대상 82명의 안경으로부터 세척 전후에 대한 각각의 세균을 채취하여 제균 여부를 확인하였다. 결과: 수돗물을 이용하여 초음파세척을 실시한 결과 세균 종의 수에 대한 변화가 없었으며 70% 소독용 알코올을 이용하여 초음파세척을 실시하였을 때는 46.2%의 제균 효과가 나타났으며 일반 세제를 이용하여 솔 세척 후 70% 알코올을 이용한 초음파세척을 실시한 결과 85.7%의 제균 효과가 나타났다. 결론: 시력교정용 안경에 존재하는 기회감염성 세균들은 세제를 이용하여 솔질 세척이 더욱 효과적이었는데 이것은 렌즈와 림의 틈새 등 접합부위 등에 세균들이 세제와 솔에 의해 제거 된 것으로 차후 청결한 안경의 관리를 위하여 안경의 정기적 분해 세척이 요구됨과 동시에 안경세척관리에 대한 가이드라인이 구축되어야 할 것으로 사료된다.

Keywords

References

  1. McLaughlin-Borlace L, Stapleton F, Matheson M, Dart JK. Bacterial biofilm on contact lenses and lens storage cases in wearers with microbial keratitis. J Appl Microbiol. 1998;84(5):827-838. https://doi.org/10.1046/j.1365-2672.1998.00418.x
  2. Lee JS, Hahn TW, Choi SH, Yu HS, Lee JE. Acanthamoeba keratitis related to cosmetic contact lenses. J Clinical & Experimental Ophthalmol. 2007;35(8):775- 777. https://doi.org/10.1111/j.1442-9071.2007.01622.x
  3. Xuguang S, Lin C, Yan Z, Zhigun W, Ran L, Shiyun L, et al. Acanthamoeba keratitis as a complication of orthokeratology. Am J Ophthalmol. 2003;136(6):1159-1161. https://doi.org/10.1016/S0002-9394(03)00635-4
  4. Young AL, Leung AT, Cheng LL, Law RW, Wong AK, Lam DS. Orthokeratology lens-related corneal ulcers in children: a case series. American Academy of Ophthalmology. 2004;111(3):590-595.
  5. Kim HS, Hwang SY, Yun CY. The bacterial contamination in glasses for vision correction. J Korean Oph Opt Soc. 2013;18(1):67-73. https://doi.org/10.14479/jkoos.2013.18.1.067
  6. Bharathi MJ, Ramakrishnan R, Meenakshi R, Kumar CS, Padmavathy SM. Ulcerative keratitis associated with contact lens wear. Indian J Ophthalmol. 2007;55(1):64-67. https://doi.org/10.4103/0301-4738.29500
  7. McLaughlin-Borlace L, Stapleton F, Matheson M, Dart JK. Bacterial biofilm on contact lenses and lens storage cases in wearers with microbial keratitis. J Appl Microbiol. 1998;84(5):827-838. https://doi.org/10.1046/j.1365-2672.1998.00418.x
  8. Koo SB, Cho SB, Park MJ, Kim SR. The investigation on ultrasonic cleaning of soft contact lenses in local optical shops and the protein removal effect by lens containers. J Korean Oph Opt Soc. 2011;16(1):31-40.
  9. Gray TB, Cursons RT, Sherwan JF, Rose PR. Acanthamoeba, bacterial, and fungal contamination of contact lens storage cases. Br J Ophthalmol. 1995;79(6):601-605. https://doi.org/10.1136/bjo.79.6.601
  10. Sohn SE, Kwak HJ. Evaluation of contact lens care pattern and contact lens case care. Korean J Vis Sci. 2007;9(3):351-356.
  11. Rose PR. Acanthamoeba, bacterial, and fungal contamination of contact lens storage cases. Br J Ophthalmol. 1995;79(6):601-605. https://doi.org/10.1136/bjo.79.6.601
  12. Seal DV, Kirkness CM, Bennett HG, Peterson M, Keratitis Study Group. Acanthamoeba keratitis in Scotland: risk factors for contact lens wearers. Contact Lens Anterior Eye. 1999;22(2):58-68. https://doi.org/10.1016/S1367-0484(99)80004-6
  13. Yun SK, Lee CS. Surface analysis of contact lens after cleaned with ultrasonic cleaner and multi-purpose solution. J Inst Nat Sci. 2006;25(1):43-52.
  14. Keates RH. Sonic sterilization of contact lenses. Am J Ophthalmol. 1998;66(6):1175-1176.

Cited by

  1. 여대생의 콘택트렌즈 착용 및 관리 실태에 따른 안구건조증과 눈 피로 vol.25, pp.4, 2013, https://doi.org/10.12799/jkachn.2014.25.4.259