DOI QR코드

DOI QR Code

Aortic Valve Replacement Using Continuous Suture Technique in Patients with Aortic Valve Disease

  • Choi, Jong Bum (Department of Thoracic and Cardiovascular Surgery, Research Institute of Clinical Medicine, Chonbuk National University Medical School) ;
  • Kim, Jong Hun (Department of Thoracic and Cardiovascular Surgery, Research Institute of Clinical Medicine, Chonbuk National University Medical School) ;
  • Park, Hyun Kyu (Department of Thoracic and Cardiovascular Surgery, Research Institute of Clinical Medicine, Chonbuk National University Medical School) ;
  • Kim, Kyung Hwa (Department of Thoracic and Cardiovascular Surgery, Research Institute of Clinical Medicine, Chonbuk National University Medical School) ;
  • Kim, Min Ho (Department of Thoracic and Cardiovascular Surgery, Research Institute of Clinical Medicine, Chonbuk National University Medical School) ;
  • Kuh, Ja Hong (Department of Thoracic and Cardiovascular Surgery, Research Institute of Clinical Medicine, Chonbuk National University Medical School) ;
  • Jo, Jung Ku (Department of Thoracic and Cardiovascular Surgery, Research Institute of Clinical Medicine, Chonbuk National University Medical School)
  • Received : 2012.11.26
  • Accepted : 2013.03.07
  • Published : 2013.08.05

Abstract

Background: The continuous suture (CS) technique has several advantages as a method for simple, fast, and secure aortic valve replacement (AVR). We used a simple CS technique without the use of a pledget for AVR and evaluated the surgical outcomes. Materials and Methods: Between October 2007 and 2012, 123 patients with aortic valve disease underwent AVR alone (n=28) or with other concomitant cardiac procedures (n=95), such as mitral, tricuspid, or aortic surgery. The patients were divided into two groups: the interrupted suture (IS) group (n=47), in which the conventional IS technique was used, and the CS group (n=76), in which the simple CS technique was used. Results: There were two hospital deaths (1.6%), which were not related to the suture technique. There were no significant differences in cardiopulmonary bypass time or aortic cross-clamp time between the two groups for AVR alone or AVR with concomitant cardiac procedures. In the IS group, two patients had prosthetic endocarditis and one patient experienced significant perivalvular leak. These patients underwent reoperations. In the CS group, there were no complications related to the surgery. Postoperatively, the two groups had similar aortic valve gradients. Conclusion: The simple CS method is useful and secure for AVR in patients with aortic valve disease, and it may minimize surgical complications, as neither pledgets nor braided sutures are used.

Keywords

References

  1. Ruchat P, Hurni M, Fischer AP, Sadeghi H. Semicontinuous suture technique for all prosthetic valve insertions: the "hoist" technique. Ann Thorac Surg 1998;65:859-60. https://doi.org/10.1016/S0003-4975(97)01412-4
  2. Qicai H, Zili C, Zhengfu H, et al. Continuous-suture technique in aortic valve replacement. J Card Surg 2006;21:178-81. https://doi.org/10.1111/j.1540-8191.2006.00121.x
  3. Nair SK, Bhatnagar G, Valencia O, Chandrasekaran V. Effect of valve suture technique on incidence of paraprosthetic regurgitation and 10-year survival. Ann Thorac Surg 2010;89:1171-9. https://doi.org/10.1016/j.athoracsur.2009.12.069
  4. D'Onofrio A, Mazzucco A, Valfre C, et al. Left ventricular remodeling, hemodynamics and early clinical outcomes after aortic valve replacement with the Pericarbon Freedom stentless bioprosthesis: results from the Italian Prospective Multicenter Trial. J Heart Valve Dis 2011;20:531-9.
  5. Hjelms E, Vilhelmsen R, Rygg IH. Continuous suture technique in prosthetic aortic valve replacement. J Cardiovasc Surg (Torino) 1982;23:145-8.
  6. Laks H, Pearl JM, Barthel SW, Elami A, Sorensen TJ, Milgalter E. Aortic valve replacement using a continuous suture technique. J Card Surg 1993;8:459-65. https://doi.org/10.1111/j.1540-8191.1993.tb00394.x
  7. Dhasmana JP, Blackstone EH, Kirklin JW, Kouchoukos NT. Factors associated with periprosthetic leakage following primary mitral valve replacement: with special consideration of the suture technique. Ann Thorac Surg 1983;35:170-8. https://doi.org/10.1016/S0003-4975(10)61456-7
  8. Agrifoglio M, Filippini S, Roberto M, Zanobini M, Gregorini L, Alamanni F. Non infective severe aortic paravalvular leakage 7 years after surgery: the role of suture technique. J Cardiothorac Surg 2011;6:60. https://doi.org/10.1186/1749-8090-6-60

Cited by

  1. Early Outcomes of Sutureless Aortic Valves vol.49, pp.3, 2013, https://doi.org/10.5090/kjtcs.2016.49.3.165
  2. Continuous Suture Technique for Aortic Valve Replacement vol.45, pp.2, 2013, https://doi.org/10.14503/thij-18-6656
  3. A running suture line for aortic valve replacement does not increase the rate of postoperative complete heart block vol.67, pp.3, 2013, https://doi.org/10.1007/s11748-018-1011-1