Abstract

Instead of extracting every selected harmonic component, the current reference of selective active power filter (APF) can be also obtained by filtering out the fundamental component from distorted load current for computation efficiency. This type of mixed current reference contains kinds of harmonic components and easily involves noises. In this condition, selective harmonic compensation must be realized by the current controller. With regard that selectivity is the most significant feature of controller, this paper presents specific comparison analysis between two types of resonant controllers: proportional-resonant (PR) controller and vector-resonant (VR) controller. The comparison analysis covers the relations, performances, and stability of both controllers. Analysis results conclude that the poorer selectivity of the PR controller could be relatively improved, but limitations from system stability make the improvement hardly realized. By contrast, the VR controller exhibits excellent selectivity and is more suitable for selective APF with mixed current reference. Experimental results from laboratory prototype validate the reasonability of analysis. And the features of each resonant controller are concluded.

Keywords

References

  1. P. Mattavelli, "A closed-Loop selective harmonic compensation for active filters," IEEE Trans. Ind. Appl., Vol. 37, No. 1, pp. 81-89, Jan./Feb. 2001. https://doi.org/10.1109/28.903130
  2. D. Yazdani, A. Bakhshai, G. Joos, M. Mojiri, "A real-time three-phase selective harmonic-extraction approach for grid-connected converters," IEEE Trans. Ind. Electron., Vol.56, No.10, pp. 4097-4106. Oct. 2009. https://doi.org/10.1109/TIE.2009.2024658
  3. Reyes S. H., Patricio S., Hyosung K., "Instantaneous reactive power theory applied to active power filter compensation: different approaches, assessment, and experimental results," IEEE Trans. Ind. Electron., Vol. 55, No. 1, pp. 184-196, Jan. 2008. https://doi.org/10.1109/TIE.2007.905959
  4. Hongyu Li, Fang Zhuo, Zhaoan Wang, Wanjun Lei, Longhui Wu, "A novel time-domain current-detection algorithm for shunt active poer filters," IEEE Trans. Power System, Vol. 20, No.2, pp. 664-651, May 2005. https://doi.org/10.1109/TPWRD.2004.835264
  5. C. Lascu, L. Asiminoaei, I. Boldea, and F. Blaabjerg, "High performance current controller for selective harmonic compensation in active power filters," IEEE Trans. power Electron., Vol. 27, No. 5, pp. 1826-1835, Sep. 2007.
  6. M. J. Newman, D. N. Zmood and D. G. Holmes, "Stationary frame harmonic reference generation for active filter systems," IEEE Trans. Ind. Appl., Vol. 38, No. 6, pp.1591-1599, Nov./Dec. 2002. https://doi.org/10.1109/TIA.2002.804739
  7. R. I. Bojoi, G. Griva, M. Guerriero, F. Farina, and F. Profumo, "Current control strategy for power conditioners using sinusoidal signal integrators in synchronous reference frame," IEEE Trans. Power Electron., Vol. 20, No. 6, pp. 1402-1412, Nov. 2005. https://doi.org/10.1109/TPEL.2005.857558
  8. A. Chandra, B. Singh, B. N. Singh, K. Al-Haddad, "An improved control algorithm of shunt active filter for vltage regulation harmonic elimination, power-factor correction, and balancing of nonlinear loads," IEEE Trans. Power Electron., Vol. 15, No. 3, pp. 495-507, May 2000. https://doi.org/10.1109/63.844510
  9. S. Fukuda, R. Imamura, "Application of sinusoidal internal model to current control of three-phase utility-interface converters," IEEE Trans. Ind. Electron., Vol. 52, No. 22, pp. 420-426, Apr. 2005. https://doi.org/10.1109/TIE.2005.843914
  10. C. D. Schauder and R. Caddy, "Current control of volgage-source inverters for fast four-quadrant drive performance," IEEE Trans. Ind. Appl., Vol. IA-18, pp. 163-171, Mar./Apr. 1982
  11. T. R. Rowan and R. L. Kerman, "A new synchronous current regulator and an analysis of current-regulated PWM inverters," IEEE Trans. Ind. Appl., Vol. IA-22, pp. 678-690, July/Aug. 1986.
  12. D. N. Zmood, and D. G. Holmes, "Stationary frame current regulation of PWM inverters with zero steady-state error," IEEE Trans. Power Electron., Vol. 18, No. 3, pp. 814-822, May 2003. https://doi.org/10.1109/TPEL.2003.810852
  13. X. Yuan, W. Merk, H. Stemmler, and J. Allmeling, "Stationary-frame generalized integrators for current control of active power filters with zero steady-state error for current harmonics of concern under unbalanced and distorted operating conditions," IEEE Trans. Ind. Appl., Vol. 38, No. 2, pp. 523-532, Mar./Apr. 2002. https://doi.org/10.1109/28.993175
  14. C. Lascu, L. Asiminoaei, I. Boldea, and F. Blaabjerg, "Frequency response analysis of current controllers for selective harmonic compensation in active power filters," IEEE Trans. Ind. Electron., Vol. 56. No. 2, pp. 337-347, Feb. 2009.
  15. A. G. Yepes, F. D. Freijedo, O. Lopez, and J. Doval-Gandoy, "High-performance digital resonant controllers implemented with two integrators," IEEE Trans. Power Electron., Vol. 26, No. 2, pp. 563-576, Feb. 2011. https://doi.org/10.1109/TPEL.2010.2066290
  16. A. G. Yepes, F. D. Freijedo, O. Lopez, and J. Doval-Gandoy, "Analysis and design of resonant current controllers for voltage-source converters by means of nyquist diagrams and sensitivity function," IEEE Trans. Ind. Electron., Vol. 58, No. 11, pp. 5231-5250, Nov. 2011. https://doi.org/10.1109/TIE.2011.2126535
  17. S. Fukuda and T. Yoda, "A novel current-tracking method for active filters based on sinusoidal internal model," IEEE Trans. Ind. Appl., Vol. 37, No. 3, pp. 888-895, May/Jun. 2001. https://doi.org/10.1109/28.924772
  18. M. Castilla, J. Miret, J. Matas, L. G. de Vicuna, and J. M. Guerrero, "Linear current control scheme with series resonant harmonic commpensator for single-phase grid-connected photovoltaic inverters," IEEE Trans. Ind. Electron., Vol. 45, No. 7, pp.2724-2733, Jul. 2008.
  19. R. Bojoi, L. Limongi, F. Profumo, D. Roiu, and A. Tenconi, "Analysis of current controllers for active power filters using selective harmonic compensation schemes," IEEJ Trans. Electr. Electron. Eng., Vol. 4, No.2, pp.139-157, 2009. https://doi.org/10.1002/tee.20392
  20. L. Limongi, R. Bojoi, G. Griva, and A. Tenconi, "Digital current-control schemes," IEEE Trans. Ind. Electron. Mag., Vol. 3, No. 1, pp. 20-31, Mar. 2009. https://doi.org/10.1109/MIE.2009.931894
  21. M. Liserre, R. Teodorescu, and F. Blaabjerg, "Multiple harmonics control for three-phase grid converter systems with the use of PI-RES current controller in a rotating frame," IEEE Trans. Power Electron., Vol. 21, No. 3, pp. 836-841, May 2006. https://doi.org/10.1109/TPEL.2006.875566
  22. M. Castilla, J. Miret, J. Matas, L. G. de Vicuna and J. M. Guerrero, "Control design guidelines for single-phase grid connected photovoltaic inverters with damped resonant harmonic compensators," IEEE Trans. Ind. Electron., Vol. 56, No. 11, pp. 4492-4501, Nov. 2009. https://doi.org/10.1109/TIE.2009.2017820
  23. W. Lenwari, M. Sumner, P. Zanchetta, "The use of genetic algorithms for the design of resonant compensators for active filters," IEEE Trans. Ind. Electron., Vol. 56, No. 8, pp. 2852-2861, Aug. 2009. https://doi.org/10.1109/TIE.2009.2018535
  24. F. Briz, M. W. Degner, and R. D. Lorenz, "Analysis and design of current regulators using complex vectors," IEEE Trans. Ind. Appl., Vol.36, No. 3, pp. 817-825, May/Jun. 2000. https://doi.org/10.1109/28.845057
  25. G. F. Franklin, J. D. Powell, and A. Emami-Naeini, Feedback Control of Dynamic System. Kelhi, India: Pearson Educ., 2002.
  26. G. C. Goodwin, S. F. Graebe, and M. E. Salgado, Control System Design. Englewood Cliffs, NJ: Prentice-Hall, 2000.
  27. A. G. Yepes, F. D. Freijedo, J.Doval-Gandoy, O. Lopez, J. Malvar, and P. Fernandez-Comesaana, "Effects of discretization methods on the performance of resonant controllers," IEEE Trans. Power Electron., Vol. 25, No. 7, pp. 1692-1712, Jul. 2010. https://doi.org/10.1109/TPEL.2010.2041256

Cited by

  1. Analysis of Phase Error Effects Due to Grid Frequency Variation of SRF-PLL Based on APF vol.16, pp.1, 2016, https://doi.org/10.6113/JPE.2016.16.1.18
  2. Stationary Frame Current Control Evaluations for Three-Phase Grid-Connected Inverters with PVR-based Active Damped LCL Filters vol.16, pp.1, 2016, https://doi.org/10.6113/JPE.2016.16.1.297
  3. A Load Compensator Based on One-Cycle Control with Plug-In Repetitive Control vol.15, pp.2, 2015, https://doi.org/10.6113/JPE.2015.15.2.443
  4. Versatile Shunt Hybrid Power Filter to Simultaneously Compensate Harmonic Currents and Reactive Power vol.10, pp.3, 2015, https://doi.org/10.5370/JEET.2015.10.3.1311
  5. A Multifunctional Dynamic Voltage Restorer for Power Quality Improvement vol.11, pp.6, 2018, https://doi.org/10.3390/en11061351